Proposal
Leonard Powers"
Steam Specialist • Mechanical Services • Valve Repair
519 West 27th Street NYC 10001
Phone 212-244-8878. Fax 212-5634761
9 East 71st Street
Richard J. Barnett, Property Manager
New York. NY 10021
212-249-1122
212-717-4672
December 16, 2010
Reference St:
5017-102
SP:
075
Due Date:
1/15/2011
Job Name/Ship To:
9 East 71st Street
Richard J. Barnett, Property M
New York, NY 10021
212-249-1122
212-717-4672
We Hereby Submit Specifications And Estimates For:
Dear Mr. Barnett:
It was a pleasure to meet you again earlier this week. As discussed, as a first step to recommending upgrades
to the existing steam and hot water systems in order to achieve maximum energy savings and efficiency,
Leonard Powers' suggests that a complete steam system check-out of the existing equipment be done.
We are pleased to submit pricing as well as a performance schedule for a yearly maintenance service
agreement based on one visit a year.
The total cost, labor during normal working hours and material, to perform one visit a year including changing the
diaphragms of two 1" Spence E2T134-704 (integral) temperature control valves once a year is $ 950.00 plus tax.
NOTE: Spence recommends that the E2 valve diaphragms be replaced once a year since they become hard
after one years steam service. This slows down the reaction time of the temperature control valves and can
create "spikes" in the hot water temperature.
Option:
9 East 71st Street Owner hereby authorizes minor repairs and/or replacement parts not to exceed $
per visit, without further written approval. (This option may benefit the owner by eliminating a return service visit
for a minor repair.)
The equipment to be covered under this agreement will include:
One 1" Spence threaded ED upper primary reducing valve
One 1-1/2" Spence threaded ED upper secondary reducing valve
One 3/4" Spence threaded ED lower primary reducing valve
One 1-1/4" Spence threaded ED lower secondary reducing valve
One solenoid valve and Honeywell aquastat for condensate dilution tank
One duplex condensate pump
Steam traps in steam room
Two Patterson Kelley hot water heaters
Two 1" Spence E2T134-704 top-mount temperature control valves
Two heat exchangers for building heat and their Siemens pneumatic control valves
Circulating water pumps
Steam traps on HW heaters
We appreciate the opportunity to quote to your requirements and look forward to working with you to improve the
safety, reliability and efficiency of the steam and hot water systems at 9 East 91st Street
EFTA00595527
Subtotal
Tax 1
Total
950.00
84.31
$1,034.31
Payment to he made as follows:
Net 30 days pending credit approval
All material Is guaranteed to be as specified. All work to be competed in a ptofessional manner according to standard practices. Any alteration or
deviation from above specifications involving extra costs will be executed only upon written orders and will become an extra charge over and above the
estimate. Purchaser agrees to pay all costs of collection. including attorneys fees Terms: Net 30 days or by date specified. A finance charge of 13
percent (an annual percentage of 18%) will be assessed to average daily balances for all items over thirty (30) days. Customer agrees to pay Leonard
Powers, Inc. reasonable attorney fees and expenses for the collection of any unpaid invoice.This proposal may be withdrawn by us if not accepted by
the above due date .
Authorized
Acceptance
Signature
Ignature
Date
EFTA00595528
9 East 71' Street
Performance Schedule
STEAM PRESSURE REDUCING VALVES
AND HOT WATER HEATERS
ONE VISIT ANNUALLY
The maintenance procedure will consist of the following:
Lubricate and check operation of circulating water pumps for hot water heaters and
building heat
Visually inspect the hot water heaters and valves for any visible damage, corrosion, leaks,
etc.
Check operation of four Spence pressure reducing valves
Check operation of two Spence temperature control valves for hot water heaters
Check and record all temperature and pressure gauge readings.
Check steam traps in steam room and for hot water heaters
Blow-down strainers for Temperature Control Valves and traps
Check hot water heaters and heat exchangers for building heat for coil leaks.
Check the temperature controls and make adjustments as required
In addition to all the above, once a year the diaphragms of two 1" Spence E2T314-704
temperature control valves will be replaced.
Upon completion of each maintenance visit, a written report containing all measurements,
results, and comments will be sent, as well as being maintained in our files.
EFTA00595529
Document Preview
PDF source document
This document was extracted from a PDF. No image preview is available. The OCR text is shown on the left.
This document was extracted from a PDF. No image preview is available. The OCR text is shown on the left.
Extracted Information
Phone Numbers
Document Details
| Filename | EFTA00595527.pdf |
| File Size | 570.7 KB |
| OCR Confidence | 85.0% |
| Has Readable Text | Yes |
| Text Length | 4,702 characters |
| Indexed | 2026-02-11T22:53:32.860094 |