Back to Results

HOUSE_OVERSIGHT_016685.jpg

Source: HOUSE_OVERSIGHT  •  Size: 0.0 KB  •  OCR Confidence: 85.0%
View Original Image

Extracted Text (OCR)

ui] Page 5 of 8 Figure 1 also depicts the approximate ICW crossings and points of entry (POEs) of the transmission mains to the Town. The scale of the map does not allow an accurate depiction of the POEs associated with the mains. Maps of the Town’s distribution system provided by the PWD, generated at a significantly larger scale, were used to reference the locations of the POEs for the transmission mains. SAMPLING AND ANALYSIS OF THE DRINKING WATER PRODUCT DELIVERED TO THE TOWN As a means to independently evaluate the quality of the drinking water being delivered to the Town, on November 14, 2008 HSA, accompanied by an employee of the City’s Public Utilities Department, sampled distribution system tap IDSE #6, representing the northern-most extent of the system, and tap 3230, representing the southern-most extent of the system,. Figure 1 depicts these sampling tap locations. Sampling was performed by modification of the City’s (distribution system) General Sampling Procedures to reflect the intended exclusion of sampling equipment, field parameter testing, associated equipment calibration requirements. Samples were collected in laboratory- supplied, unpreserved and pre-preserved containers. As required by select analytical methodologies, at the sampling locations preservative was added to those sample containers immediately prior to filling or to the water sample immediately prior to sealing the sample container. Collected water samples were submitted to FDOH/NELAC-certified testing laboratories for analysis for typical public potable water system routine and compliance monitoring parameters including Primary Drinking Water Standards (excluding select Disinfection Byproducts, Haloacetic Acids; Bromite; and Chlorite), for Secondary Drinking Water Standards, and for Total Coliform as listed in the Florida Administrative Code rule 62-550. Test America Laboratories performed all of the analyses for chemical parameters. Jupiter Environmental Laboratories performed the analyses for the microbiologics. RESULTS FROM INDEPENDENT ANALYSIS OF THE CITY’S DRINKING WATER PRODUCT Results of laboratory analysis for target Primary and Secondary Drinking Standards yielded all chemical and physical parameters below method detection limits (MDLs) or less than respective maximum contaminant limits (MCLs). Results of laboratory analysis for target microbiologicals yielded an absence of Total Coliform in the water samples collected from northern-most Tap A (IDSE #6) and southern-most HOUSE_OVERSIGHT_016685

Document Preview

HOUSE_OVERSIGHT_016685.jpg

Click to view full size

Extracted Information

Dates

Document Details

Filename HOUSE_OVERSIGHT_016685.jpg
File Size 0.0 KB
OCR Confidence 85.0%
Has Readable Text Yes
Text Length 2,540 characters
Indexed 2026-02-04T16:28:52.356896