OREGENCY Regency HorizonTM HZ4OE Gas Fireplace WARNING: If the information in these instructions are not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. Installation and service must be performed by a qualified installer, service agency or the gas supplier. It,ted by. EDI Intertek Owners & Installation Manual MODELS: 14Z40E•NG1 Natural Gas I4Z40E•LP1 Propane FOR YOUR SAFETY What to do if you smell gas: • Do not try to light any appliance • Do not touch any electrical switch: do not use any phone in your building. • Immediately call your gas supplier from a neighbour's phone. Follow the gas supplier's instructions. • If you cannot reach your gas supplier, call the fire department. Installer: Please complete the details on the back cover and leave this manual with the homeowner. Homeowner: Please keep these instructions for future reference. 919 165 FM FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1144 05/29/12 EFTA00301420 MANUFACTURED MOBILE HOME REQUIREMENTS INFORMATION FOR MOBILE/MANUFACTURED HOMES AFTER FIRST SALE This Regencr product has been tested and listed by Warnock Hersey/Intertek as a Direct Vent Wall Furnace to the following standards: VENTED GAS FIREPLACE HEATERS ANSI Z21.88-2009/ CSA 2.33-2009 and GAS-FIRED APPLIANCES FOR USE AT HIGH ALTITUDES CAN / CGA 2.17-M91. This appliance may only be installed in an aftermarket permanently located, manufactured (U.S.A only) or mobile home, where not prohibited by local codes. This Direct Vent System Appliance must be installed in accordance with the manufacturers installation instructions and the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, or the current Standard of Fire Safety Criteria for Manufactured Home Installations, Sites, and Communities ANSI/NFPA 501A, and with CAN/CSA Z240-MH Mobile Home Standard in Canada. This appliance installation must comply with the manufacturers installation instructions and local codes, it any. In the absence of local codes follow the current National Fuel Gas Code, ANSI 2223.1 and the current National Electrical Code ANSI/NFPA 70 in the U.S.A., and the current CAN/CGA B149 Gas Installation Code and the current Canadian Electrical Code CSA C22.1 in Canada. This appliance comes equipped with a dedicated #8 Ground Lug for attachment of the ground wire to the steel chassis as applicable to local codes. The appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70. or the Canadian Electrical Code, CSA C22.1. This appliance can only be used with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases. Ensure that structural members are not cut or weakened during installation. This appliance may be installed as an OEM installation in a manufactured home (USA only) or mobile home and must be installed in accordance with the manufacturer's instruction and the Manufactured Home Construction and Safety Standard, Title 24 CFR. Part 3280, in the Untied States, or the Standard for Installation in Mobile Homes, CAN/CSA Z240 Mkt, in Canada. WilkA WARNING! lir HOT GLASS WILL CAUSE BURNS DO NOT TOUCH GLASS UNTIL COOLED NEVER ALLOW CHILDREN TO TOUCH GLASS Regency HorlzonTM HZ40E Gas Fireplace EFTA00301421 To the New Owner: Congratulations! You are the owner of a state-of-the-art Gas Fireplace by REGENCY°. The HZ40E has been designed to provide you with all the warmth and charm of a fireplace at the flick of a switch. The model HZ4OE has been approved by Warnock Hersey/Intertek for both safety and efficiency. As it also bears our own mark, it promises to provide you with economy, comfort and security for many trouble free years to follow. Please take a moment now to acquaint yourself with these instructions and the many features of your Regency Fireplace. marmoithu. We recommend that our products be FIREPLACE IRSTRLITC installed and serviced by professionals who are certified in the U.S. by the National Fireplace Institute° (NFI) or in Canada by Wood Energy Technical Wood Emmy Wake leateleg NFI CERTIFIED., Training (WETT). ONE REGENCY ONE TREE TM Regency HorlzonTM HZ40E Gas Fireplace EFTA00301422 TABLE OF CONTENTS SAFETY DECAL Copy of Safety Decal REQUIREMENTS 5 4" x 6-5/8" venting High Elevation Gas Line Installation Pilot Adjustment Gas Pipe Pressure Testing 880 S.I.T. Valve Description Aeration Adjustment 35 36 36 36 36 36 AC power adaptor installation (for surefire systems) 37 MA Code - CO Detector 6 Wiring Diagram 38 (for the State of Massachusetts only) 6 proflame system GT 38 proflame system GTM 38 INSTALLATION proflame system GTMF with optional fan 39 optional fan Wiring Diagram 40 Important Message Before You Start General Safety Information Installation Checklist 8 8 8 9 Without ProFlame GTMF system Optional Remote Control Receiver Wall Switch wall mount On / Off Switch and battery compartment installation and/or receiver installation 40 41 41 42 Locating Your Gas Fireplace Heatwave Duct System Heat Release kit Clearances Mantel Clearances Mantel Leg Clearances Unit Assembly Prior To Installation Nailing Strips Installation Access panel Front face Nailing strip installation Framing Dimensions 9 9 9 10 11 11 12 12 12 12 13 GTMF remote installation Optional fan Installation Optional fan Installation - into existing installations Inner Panel Installation Glass Crystals or optional ceramic stones Optional Pebble / Crystal Installation Glass door Installation Optional mesh glass guard 4 piece faceplate installation Inner and outer door frame installation 43 46 47 49 50 51 52 53 54 55 Non-Combustible Requirements Non-combustible facing installation Framing & Finishing 14 14 15 OPERATING INSTRUCTIONS Framing & Finishing 16 Operating Instructions 56 Non-Combustible Requirements 16 First Fire 56 Exterior Vent Termination Requirements 17 Lighting Procedure 56 4" x 6-5/8" Rigid Pipe 18 Shutdown Procedure 56 Cross Reference Chart only 18 Normal Operating Sounds of Gas Appliances 56 Vent Restrictor Position 20 Copy of Lighting Plate Instructions 57 Venting Introduction 21 Maintenance Instructions 58 Venting Arrangement for Horizontal Terminations 21 Glass Gasket 58 Horizontal Terminations 22 Glass Door 58 Flex Vent 4" x 6-7/8" 22 Glass Replacement 58 Horizontal terminations 23 General Vent Maintenance 58 Rigid Pipe 4" x 6-5/8" 23 Valve assembly Replacement 59 Horizontal Terminations Rigid Pipe 4" x 6-5/8" Vertical terminations Rigid Pipe 4" x 6-5/8" 24 24 27 27 PARTS LIST Venting Arrangement for Vertical Terminations 28 Main Assembly 60 Vertical Termination with Co-Linear Flex System 29 Accessories 61 Vertical Terminations Rigid Pipe 4" x 6-5/8" Venting Arrangements - Vertical Terminations Unit Installation with Horizontal Termination 30 30 32 33 WARRANTY 4" x 6-5/8" venting 33 The Warranty: Limited Lifetime 63 Unit Installation with Horizontal Termination Unit installation with Vertical Termination 34 35 Regency Horizon"' HZ40E Gas Fireplace EFTA00301423 SAFETY LABEL This is a copy of the label that accompanies each HZ40E-NG1 and HZ40E-LP1 Direct Vent Gas Fireplace. We have printed a copy of the contents here for your review. NOTE: Regency, units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one. COPY OF SAFETY DECAL Intertek 4001172 O NATURAL GAS: Model H240E-NG1 Minimum supply pressure Manifold pressure Orifice sue Maximum input Minimum input Altitude Lined: VENTED GAS FIREPLACE HEATER! FOYER AU GAZ A EVACUATION DO NOT REMOVE THIS LABEL r NE PAS ENLEVER CETTE ETIQUETTE Certified for/Leith& pour: CANADA and U.S A. Tested to: CAN/CGA-2.17-M91(R2009) ANSI 221.88-2009/CSA 2.33-2009 MAY BE INSTALLED IN MANUFACTURED (MOBILE' HOMES AFTER FIRST SALE. litREPN.cT Serial No/ No de aerie 412 5if WC/C.E. (125IPa) 34 WCIC.E. f327IPa) IMO CA1S 26.000 Mufti (7.61 kW) 18,000 Mufti (5 28 kW) 04500 Dpi (0-1372m) O PROPANE GAS: Model HZ40E-LPI Mnimum supply pressure Manifold pressure Orifice sae MaxmLon Input Minimum Input Altitude 11' WC (2.73 kpa) 10' WC1C.E. (2491Pa) #53 CMS 25.500 Btuiti (7.47kW) 21.000 Bbih (6.15 kW) 04500 fipl (0-1372m) APPAREIL FONCTIONNANT AU NATURAL GAS CONCU POUR ETRE POELE: Mode* HZ40E-NG1 Preston mnimurn Preston a la aibulum dechappement Neves Grandeur de nnecteur Debt Calonligue maximum salon Yaltitude EQUIPE A CUISINE POUR GAZ PROPANE CONCU POUR ETRE POELE: ModeleHT.40E-LP1 Preston Minimum Presslon a b turauNre dolchapperneM elevee Grandeur de I1Mecteur DeWI Calorilque maxenum scion raktude Minimum Clearances to Combustibles I Degagement Minimum De Materisux Combustibles DOOR SEAL: Please check that the door is properly sealed Side Walls A Er (203mm) Ceiling 8 22' (559mm) Min. Mantel Height C 1r (432mm) Max. Mantel Depth 13" (330mm) Alcove Width E 84" (1524mm) Alcove Depth F 36- (2134mm) lawsuitsction Munui let minute:ens) This appliance must be inslallad n aconlance *Mb local codes. if any: if nom. Sow the National Fool Gas Code. ANSI 2223.1. cr Natural Gas and Propane Install on Code. GSA0169.1. This MpliaMe muslin :Walled ine000rdance wen me StandiedCAN:CSAZ2401M. M0bleHousino.in Canada. Or wsb me HanulachgedHolneCcoseucbonandSalgYSlandard. tee 24 CFRP(0 3280.in the Veiled SOWS. C. wails, SW) StaMarO PS Mt apoicams.ANSUKSBCS A225 liNFPASOI A. Mantoactured Horne IntlellatiCOS Standard C•ANSI All 9.20u NFPA SOIC standard reeRecreed4no Wades This appliamo is only forum ailh the type dips irdicalcd rolls recap plate and may be mimed n an aftermarkel. permanently lomat manufactuogrnobilaThomewhere nc4pohlaited bylocal cedes. See vanes manual fordetals. This applance d notoomembie torus, enhothareases.wiless a certifed iutisused. Installer reooenFlselonles codes ourealementsOcata. ou.en rabeence de MK Nolemerts. INICOIOS 01:la 2223.1. National FuelGasCode ouCSA43149.1 en vIgueur Installer repoereil salon le norms CAN'CSA-Z240. Sane WM. MilltiOn MOON, Ou CANCSA-Z240 VC. VOIColOS 00 CaMOIn0. Ou la tonne 24 CFR Pert 3280. ManulaCtunid HOMO Consau(ton and Safety Standard. Si ces norm*, ne pampas acclimates. utilsez le normeANSUNCSBCSA225.1/NFPA 501A. Manufactured Home Installations Standard. ouANSI AI 19 2 ou NFPASOIC Standardfor Recreational Vehicles. Cal apparel don etre dela. unouemem avec to tyDedepa2 ndiove suns plaque signeXHIgue.Cecamaret.o errs ru"s"e O&M. unBmiton preeabnqueeou moDhe le -V. SeuleclaliV)InSIfille daMtoule Si les retflaMenISIOG3us le DaMeltenl Writ WOG Cla IVIIMSSor pets pluSde fenSeirecnertS CSISCOOMII= [OS COnAutible DOurunS ulllexIbOnaveCilliti$2.aSurS. on. If CuSSOCONDS *SI Vella Thls vented gas fireplace heater is not forme wither Altars. Ne pas utikserde Niro a air avec ce foyerau pas itevacuatIon. FORUSEWITHGLASSDOORSCERTIFIEDWITH THEAPPLIANCEONLY POUR UMISATIONUMOUEMENT AVEC LESPORTESENVERRECERTIFIEESAVEC L'APPAREIL Fan (1Pala 258-911) vase," canals. Fdroon au Canals Ela-tical supply l Electrique 115VAC. 1.13A 6011t NOT FOR USE WITH SOLID FUELS.! NE PAS UTILISER AVEC DU COMEIUSTBLE SOLIDE. FPI Fireplace Products International Ltd. Delta. BC. Canada 9i#166 For the State of Massachusetts, installation and repair must be done by a plumber or gasfitter licensed in the Commonwealth of Massachusetts. For theStateof Massachusetts. flexible con- nectors shall not exceed 36 inches in length. For the State of Massachusetts, the appli- ances individual manual shut-off must be a t-handle type valve. The State of Massachusetts requires the installation of a carbon monoxide alarm in accordance with NFPA 720 and a CO alarm with battery back up in the same room where the gas appliance is installed. Regency HorizonTM HZ40E Gas Fireplace EFTA00301424 REQUIREMENTS MA Code - CO Detector (for the State of Massachusetts only) 5.08: flodlfleatIons to NFPA-54. Chapter 10 (2) Revise 10.8.3 by adding the following additional requirements: (a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in pan for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall be satisfied: 1. INSTALLATION OF CARBON MONOXIDE DETECTORS. At the time of installation of the side wall horizontal vented gas fueled equipment, the installing plumber or guiltier shall observe that a hard wired carbon monoxide detector with an alarm and battery back-up is installed on the floor level where the gas equipment is to be installed. In addition, the installing plumber or gasfitter shall observe that a battery operated or hard wired carbon monoxide detector with an alarm is installed on each additional level of the dwelling, building or structure served by the side wall horizontal vented gas fueled equipment. It shall be the responsibility of the property owner to secure the services of qualified licensed professionals for the installation of hard wired carbon monoxide detectors a. In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic. the hard wired carbon monoxide detector with alarm and battery back-up may be installed on the next adjacent floor level. b. In the event that the requirements of this subdivision can not be met at the time of completion of installation, the owner shall have a period of thirty (30) days to comply with the above requirements: provided, however. that during said thirty (30) day period. a battery operated carbon monoxide detector with an alarm shall be installed. 2. APPROVED CARBON MONOXIDE DETECTORS. Each carbon monoxide detector as required in accordance with the above provisions shall comply with NFPA 720 and be ANSUUL 2034 listed and IAS certified. 3. SIGNAGE A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum height of eight (8) feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled healing appliance or. equipment. The sign shall read in print size no less than one-half(1f2) inch in size. "GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OBSTRUCTIONS". 4. INSPECTION. The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless, upon inspection, the inspector observes carbon monoxide detectors and signagc installed in accordance with the provisions of 248 CMR 5.08(2X2)1 through 4. (b) EXEMPTIONS: The following equipment is exempt from 248 CMR 5.08(2)(8)1 through 4: 1. The equipment listed in Chapter 10 entitled "Equipment Not Required To Be Vented" in the most current edition of NFPA 54 as adopted by the Board: and 2. Product Approved side wall horizontally vented gas fueled equipment installed in a room or structure separate from the dwelling, building or structure used in whole or in part for residential purposes. (c) MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM PROVIDED. When the manufacturer of Product Approved side wall horizontally vented gas equipment provides a venting system design or venting system components with the equipment. the instructions provided by the manufacturer for installation of the equipment and the venting system shall include: 1. Detailed instructions for the installation of the venting system design or the venting system components: and 2. A complete parts list for the venting system design or venting system. (d) MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM NOT PROVIDED. When the manufacturer of a Product Approved side wall horizontally vented gas fueled equipment does not provide the parts for venting the flue gases. but identifies "special venting systems", the following requirements shall be satisfied by the manufacturer: 1. The referenced "special venting system" instructions shall be included with the appliance or equipment installation alit:Will:MS: and 2. The "special venting systems" shall be Product Approved by the Board. and the instructions for that system shall include a pans list and detailed installation instructions. (c) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment. all seating instructions. all pans lists for venting instructions. and'or all venting design instructions shall remain with the appliance or equipment at the completion of the installation. Regency Horizon"' HZ40E Gas Fireplace EFTA00301425 DIMENSIONS 45 5/8" PEW 39-13/16' 1 — . —Iv :2 1. — 364- — a , — 43X1 (1092mm 341,4- (972mm) (902m1 mew El 48. (1238mrn) 4 36" (gum.) Regency I-Icemen' 14240E Gas Fireplace EFTA00301426 INSTALLATION IMPORTANT MESSAGE SAVE THESE INSTRUCTIONS The Gas Fireplace must be installed in accordance with these instructions. Carefully read all the instructions in thismanual first. Consult the'authority having jurisdiction"todeterminetheneed for aperrnit prior tostarting theinstallation. It is the responsibility of the installer to ensure this fireplace is installed in compliance with manufacturers instructions and all applicable codes. BEFORE YOU START Safe installation and operation of this appliance requires common sense, however, we are required by the Canadian Safety Standards and ANSI Standards to make you aware of the following: INSTALLATION AND REPAIR SHOULD BE DONE BY AN AUTHORIZED SERVICE PERSON. THE APPLIANCE SHOULD BE INSPECTED BEFORE USE AND AT LEAST ANNUALLY BY A PROFESSIONAL SERVICE PERSON. MORE FREQUENT CLEANING MAY BE REQUIRED DUE TO EXCESSIVE LINT FROM CARPETING. BEDDING MATERIAL,ETC.IT IS IMPERATIVETHAT CONTROL COMPARTMENTS.BURNERS AND CIRCULATING AIR PASSAGEWAYS OF THE APPLIANCE BE KEPT CLEAN. DUE TO HIGH TEMPERATURES, THE APPLIANCE SHOULD BE LOCATED OUT OF TRAFFIC AND AWAY FROM FURNITURE AND DRAPERIES. WARNING: FAILURE TO INSTALL THIS APPLIANCE CORRECTLY WILL VOID YOUR WARRANTY AND MAY CAUSE A SERIOUS HOUSE FIRE. CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERATURES. ESPE- CIALLY THE FIREPLACE GLASS. AND SHOULD STAY AWAY TO AVOID BURNS OR CLOTHING IGNITION. YOUNG CHILDREN SHOULD BE CARE- FULLY SUPERVISED WHEN THEY ARE IN THE SAME AREA AS THE APPLI- ANCE. TODDLERS.YOUNG CHILDREN AND OTHERS MAY BE SUSCEPTIBLE TO ACCIDENTAL CONTACT BURNS. A PHYSICAL BARRIERS IS RECOMMEND- ED IF THERE ARE AT RISK INDIVIDUAL IN THE HOUSE. TO RESTRICT ACCESS TO A FIREPLACE OR STOVE. INSTALL AN ADJUSTABLE SAFETY GATE TO KEEP TODDLERS, YOUNG CHILDREN AND OTHER AT RISK INDIVIDUALS OUT OF THE ROOM AND AWAY FROM HOT SURFACES. CLOTHING OR OTHER FLAMMABLE MATERIAL SHOULD NOT BE PLACED ON OR NEAR THE APPLIANCE. GENERAL SAFETY INFORMATION 1) The appliance installation must conform with local codesor, in theabsenceof localcodes, with the current Canadian or National Gas Codes. CANI -B149orANSI Z223.1 Installation Codes. 2) The appliance when installed, must be electrically grounded in accordance with local codes, or in the absence of local codes with the current National Electrical Code. ANSI/NFPA 70 or CSA C22.1 Canadian Electrical Code. 3) See general construction and assembly instructions. The appliance and vent should be enclosed. 4) This appliance must be connected to the specified vent and terminationcaptotheoutside of the building envelope. Never vent to another room or inside a building. Make sure that the vent is fitted as per Venting instructions. 5) Inspecttheventingsystem annually forblockage and any signs of deterioration. 6) Venting terminals shall not be recessed into a wall or siding. 7) Any safety glass removed for servicing must be replaced prior to operating the appliance. 8) To prevent injury, do not allow anyone who is unfamiliarwiththeoperation to usethefireplace. 9) Wear gloves and safety glasses for protection while doing required maintenance. 10) Be aware of electrical wiring locations in walls and ceilings when cutting holes for termination. 11)Under no circumstance should this appliance be modified. Parts that have to be removed for servicing should be replaced prior to operating this appliance. 12) Installation and any repairs to this appliance should be done by a qualified service person. A professional service person should be called to inspect this appliance annually. Make it a practice to have all of your gas appliances checked annually. 13) Do not slam shut or strike the glass door. 14) Under no circumstances should any solid fuels (wood. paper, cardboard, coal. etc.) be used in this appliance. 15) The appliance area must be kept clear and free of combustible materials. (gases andotherflam• made vapours and liquids). Emissions from burning wood or gas could contain chemicals known to the State of Califomia to cause cancer, birth defects or other reproductive harm. Regency Horizon"' HZ40E Gas Fireplace EFTA00301427 INSTALLATION INSTALLATION CHECKLIST 1) Locate appliance a) Room location (Refer to' ocating Your Gas fireplace section) b) Clearances to Combustibles (Refer to 'Clearances" section) c) Mantle Clearances (Refer to "Mantel Clearances' section) d) Framing 8 Finishing Requirements (Refer to "Framing 8 Finishing" section) e) Venting Requirements (Refer to "Venting' section) 2) Position nailing strips (Refer to 'Unit Assembly Prior to Installation). 3) Slide unit into place. 4) Remove installation access panel. 5) Install vent (Refer to 'Venting Arrangement' sections). 6) Make gas connections (Refer to "Gas Line Installation section). 7) Make electrical connections to receptacle supplied with unit (recommended). 8) Install 4 AA batteries into receiver/switch box or use optional AC power adaptor. 9)Testthe pilot (Refer to 'PilotAdjustmenrsection). 10) TestGas Pressure (Referto"Gas Pipe Pressure Testing" section). 11) Install standard and optional features. Refer to the following sections: a) b) c) d) e) f) Glass Crystals/ Optional Ceramic Stones Optional Firebox Base Pebbles Optional Reflective Panels Optional Fan Faceplate Remote Control or Wall Thermostat and 10ft. wire harness. 12) Reinstall installation access panel. 13) Final check. Before leaving this unit with the customer, the installer must ensure that the appliance is firing correctly and operation fully explained to customer. This includes: 1) Clocking the appliance to ensure the correct firing rate (rate noted on label 26.000 Equal (NG).25.500 Btum (LP)after burning appliance for 15 minutes. 2) If required. adjusting the primary air to ensure that the flame does not carbon. First allow the unit to bum for 15.20 min. to stabilize. CAUTION: Any alteration to the product that causes sooting orcarbonIng that results In dam- age Is not the responsibility of the manufacturer. LOCATING YOUR GAS FIREPLACE 1) When selecting a location for your fireplace. ensure that the clearances are met. 2) The appliance must be installed on a flat. solid. continuous surf ace For example a wood. metal or concrete floor or in a raised (on the wall) ap- plication. The appliance must be installed on a metal or wood panel extending the full width and depth of the appliance. 3) The HZ40E Direct Vent Gas Fireplace can be installed in a recessed position or framed out into the room as in A. B. C and D. See Diagram 1. Diagram A) B) C) D) TET A Flat on Wall Flat on Wall Comer Recessed into Wall/Alcove Comer 4) This appliance is Listed for bedroom installations using the standard Remote (thermostat system). Some areas may have funher requirements. check local codes before installation. 5) The HZ40E Direct Vent Gas Fireplace is approved for alcove installations, see "Clearances" section for details. 6) We recommend that you plan your installation on paper using exact measurements for clearances and floor protection before actually installing this appliance. Have an authorized inspector. dealer. orinstaller reviewyour plans before installation. Note: For vent terminations refer to "Exterior Vent Termination Locations" section. Heat Wave asvarr---er HEATWAVE DUCT SYSTEM OPTIONAL KIT #946-556 The HeatWave Air Duct Kit increases the effectiveness of your fireplace by dispersing warm air from the ireplace to remote locations in the same room or other rooms in your home. Up to two kits may be installed on the fireplace. Please Note: Only 1 HeatWave kit may be oper- ated at one lime. This includes the internal blower option as well. alltur>"•=1.0 ," Heat Wave The HeatWave Duct Kit has different clearance andframingrequirements.cbeck the HeatWave manual for details. OPTIONAL HEAT RELEASE KIT #946-570 The Heat Release Kit expels warm air from the fireplace to the outside of the building. allowing the fireplace to be operated with less heat entering the room. The kit may be used on either the left or right side. Regency Horizon"' HZ40E Gas Fireplace EFTA00301428 INSTALLATION CLEARANCES The clearances listed below are Minimum distances unless otherwise stated: A major cause of chimney related fires Is failure to maintain required clearances (air space)to combustible materials. It is of the greatest importance that this fireplace and vent system be Installed only in accordance with these Instructions. Caution Requirements The top. back and sides of the fireplace are defined by standoffs. The metal ends of the standoff may NOT be recessed into combustible construction. WARNING Fire hazard Is an extreme risk if these clearances (air space) to combustible materials are not adhered to. It is of greatest importance that this fireplace and vent system be installed only in accordance with these instructions. Clearance: Dimension Measured From: A: Mantel Height (min.) 1T (330mm) Top of Fireplace Opening B: Sidewall (on one side) 8' :203mm: Side of Fireplace Opening C: Ceiling (room and/or alcove) 22" (559mm) Top of Fireplace Opening D: Mantel Depth (max.) 1r (330mm) 22" Above Fireplace Opening E: Alcove Width 844 (2134mm) Sidewall to Sidewall (Minimum) F: Alcove Depth 36' (914mm) Front to Back Wall (Maximum) G: From Floor 27' (686mm) Top of Fireplace Opening Note: 0" No hearth required E Alcove r ife Release Kit have different clearance The HeatWave Duct Kit and the Heat iwites.•S and framing requirements. check the HeetWaveand Heat Release manual for details. lint Release MI Flue Clearances to Combustibles Horizontal Top Horiztonal . Side Horiztonal • Bottom Vertical 3" 2" Passing through wall. floor/ceiling when firestop is used. F 1 2" Installed close to ceiling. r Regency Horizon"' HZ40E Gas Fireplace EFTA00301429 INSTALLATION MANTEL CLEARANCES Due to the extreme heat this fireplace emits, the mantel clearances are critical. Combustible mantel clearances from top of front facing are shown in the diagram on the right. Note: Ensure the paintthat Is used on the mantel and the facing is"high quality" orthe paint may discolour. 14 12 10 8 6 4 2 0 ll l l l l l t l l t l l l 26- 20 - 10- - 0 To Unit Base 1" (25mm) 22"(559mm) 2T Top of Fireplace Opening Combustible Material Metal Stud (On Edge) Facing Non-combustible 17 Standoff 4 MANTEL LEG CLEARANCES Combustible mantel leg clearances as per diagram: 5-11/16"(144mm Non-Combustible Allowable mantel legp rojection Regency Norizonm 14240E Gas Fireplace EFTA00301430 INSTALLATION UNIT ASSEMBLY PRIOR TO INSTALLATION The nailing Strips must be correctly positioned and attached before unit is slid into position. NAILING STRIPS The nailing strips come attached to the unit. There is 1 plate on each side. on the top. There also two on the bottom. The top and side nailing strips are secured to the framing. The bottom nailing strips are IMPORTANT NOTE Framing depth measurement is noted with the nailing strips set as far forward on the firebox as possible. The nailing strips can be adjusted back up to 1 -1/24 to allow for varying thicknesses in noncombustible material & wall finishes. INSTALLATION ACCESS PANEL The unit is equipped vMh a removable access panel for pre-finish installation of optional components this panel is located on the lower front face. 1) Remove lower front face nailing strips (2 screws per nailing strip). 2) Remove 8 screws to remove access panel. 3) Easier access to gas connection with panel removed. 4) Install any optional components with access panel removed. 5) Reinstall access panel with B screws and lower front face nailing strips (2 screws per strip) - prior to installing any facing material Note: Access panel is no longer usable once fadng material installed. Installation Access Panel FRONT FACE NAILING STRIP INSTALLATION Required when the combined facingilinishing material is 112'. If using material which is thicker than 1/2'. the nailing strips are not required and should be removed and discarded. 1) The 5 front nailing strips are only used if the facing/finishing material is a combined 1/2' in thickness. This enables the fadng and finishing materials to be securely fastened to a solid surface. 2) Follow instructions on non-combustible facing installation for pre- drilling holes prior to attaching the noncombustible material supplied with this unit. 3) The sidettop nailing strips which are attached to this unit will also need to be adjusted. See Framing and finishing in this manual. Lower front nailing strips Regency Horizon"' HZ40E Gas Fireplace EFTA00301431 INSTALLATION FRAMING DIMENSIONS Framing DimensiOnS B 1) G J K L * Framing depth measu Omani is noted with the nailing strips set as far forward on the firebox as possible. The nailing ships can be adjusted back up to 1- to allow for varying thicknesses in non-combustible material & wall finishes. Description Framing Height EMMIIML_ Framing Depth* Minim Coiner Wall Depth Comer Vent Centerline Height Nona Gas Connection Opening Height Gas CSE Gas Connection Inset Gas Connection Opening Width HZ40E IME 42' (1067mm) taa C1 Horizontal Vent 19-7116' (495mm) C2 Vertical Vent 23-7/16" (596mm) Vertical rise -terminating horizontal 57-18" (1457mm) 36 - (921mm) 1r (432m01) 2" 151mm) 4 - 3/16" (106mm) -- al 8. 5116' (211mm) a2" (89mm) Note: Al other framing may be of wood construction. Regency Hodzonm FiZ40E Gas Fireplace EFTA00301432 INSTALLATION NON-COMBUSTIBLE REQUIREMENTS AI three pieces (top. 2 sides) are now supplied to meet the non combustible requirements. Previously only the top was supplied Calcium silicate board is a high • grade material with cement. quartz. natural and selected minerals as the main raw materials. It is widely used for partitions and ceilings in buildings. It is fire proof and earthquake proof. II finishing the wall above the unit with materials such as tile, brick, marble. etc. non-combustible board available from the building supply store can be used. Note: Calcium Silicate is 1/2' thick Metal Stud g • • • g ;TA nE • 10' (252=1) el In 5-11/16- (144mm) 51.5116' (1303mm) NON-COMBUSTIBLE FACING INSTALLATION Caution: The noncombustible board supplied with this unit can be damaged if dropped or struck. Handle with care. 1) Using drywall screws • secure non combustible material around unit, framing and top nailing strip every 6 inches. Important Note: To avoid cracking the board • pre-drill holes prior to securing to unit/ framing. 2) Wipe any debris/dust from the non combustible material and drywall. 3) Prior to taping and mudding it is highly recommended to prime the facing using a quality primer. This will ensure proper adhesion of both the tape and mud. The supplied board is very porous. 4) Tape the seams using a mesh type tape. 5) Mud seams as normal. We recommend using a product called Durabond high strength compound • for the first coat. This product can be found at any hardware store. Mud must be cured as per manufacturers recommendations. 6) Prime wall for a second time for proper adhesion of paint 7) Paint walls using a high quality paint which will withstand the high temperatures being emitted from this appliance. Non combusIblie board Apnea v41b unt 1' Metal Stud (header) on edge ►, A Metal Stud • gen.'s...Ana bawd seised vein um. 14:0 combust/So loud MUS1 BE PRIMED. Regency Horizon"' HZ40E Gas Fireplace EFTA00301433 INSTALLATION FRAMING & FINISHING 1) Frame in the enclosure for the unit with framing material. IMPORTANT: The framed opening must be of non-combustible material. Note: When constructing the framed opening, please ensure there Is access to Install the gas lines when the unit is Installed. 2) For exterior walls, insulate the enclosure to the same degree as the rest of the house, apply vapour barrier and drywall. as per local instal- lation codes. (Do not Insulate the fireplace Itself.) WARNING: Failure to insulate and add vapor barriers to the inside of the exterior wall will result in operational and performance problems including, but not limited to: excessive condensation on glass doors, poor flame package, carbon, blue flames etc. These are not product related issues. 3) The unit does not have to be completely enclosed in a chase. You must maintain clearances from the vent to combustible materials: See "Clearances" section. Combustible materials can be laid against the side and back standoffs and the stove base. 4) Noncombustible material (ie. tile, slate. etc) may be brought upto and overlap the unit (top and bottom) ensuring that the maximum thickness does not go beyond the 1.112" as shown in the diagram below. The faceplate will not be able to be mounted if finished material is beyond 1 -1 /Y. 1-'4" (38mm) Edge of __ flange on fireplace 1/2" required between faceplate + finished wall 1:W (38mm) Nailing Strip IMPORTANT: 112" gap required between faceplate and finished wall when using 4 pee. Faceplate (Part # 256.924, 256.926, 256.927) 5) If material such as brick, stone. etc extends past the faceplate depth (1.112-). when finishing around the faceplate, the minimum opening dimensions noted below must be adhered to ensuring for the removal of the faceplate and for the safe operation of this appliance. NOTE: Spacing of 1" around the completed surround must be adhered to. 52.31C I is. if Unit shown with 4 piece faceplate 47- .1115- Unit shown with inner and outer door frame I . I E LTT i_ 39-13/16" IL • to eb Unit shown with inner door frame only Regency Norlzonm 14240E Gas Fireplace EFTA00301434 INSTALLATION FRAMING & FINISHING 1/2" 1" Nailing Strip 1/2 " Forward 3" (flush) Nailing Strip 1' Forward Unit Unit ` —Nailing Strip Flush w/unit Factory Set Note: Depending on the material used for finishing, the nailing strips must be set accordingly so that the finished material is always at the 1.1/2' edge of the flange. I 1 4 E V ZO? E CAn 10' (252mm) NON-COMBUSTIBLE REQUIREMENTS Metal Stud (header) on edge ► Metal Stud A • 5-11/16" 51-5/15' (1303mm) May be combustible (ie. 1/2"dryw • 33.13416• (859mni) (144mm) Regency Horizon"' HZ40E Gas Fireplace EFTA00301435 INSTALLATION EXTERIOR VENT TERMINATION REQUIREMENTS BITI0RINO110 Vent Termination Q Air Suppry Owlet E Area whet* terminal a nol perrritted Minimum Clearance Requirements Canada' USA2 A Clearance above grade. veranda. porch. deck. or balcony 12130cm) 12130cm) 8 Clearance to window or door that may be opened 12130cm) cr (23crn) C Clearance to permanently closed window ' 0 Vertical clearance to ventdated soffit located above the ternwial within a horizontal distance of 2 feet (6Icm) from the center Ike of the terminal (check with the local code) 19148cm) 19148cm) E Clearance to unventiLated soffit 19148cm) 19 '(48cm) F Clearance to outside corner: with AstroCap Termination Cap. 7118cm) 7118cm) Clearance to outside corner: with all other approved Termination Caps. 13133cm) 13133cm) G Clearance to inside corner: with AstroCap Termination Cap 7118cm) 71113cm) Clearance to inside corner: with all other approved Termination Caps. 13133cm) 13 133cm) H Clearance to each side of center line extended above metedregulator assembly 36 190cmr J Clearance to service regulator vent outlet 36'(90cm) ' K Clearance to non-mechanical air supply inlet to building or the combustion air inlet to any other appliance 12130cm) r (23cm) L Clearance to a mechanical air supply inlet #3' (91cm) above if withal 10' (3rn) horizontally. 7211.8m) 36•(90cn)e fA Clearance above paved sidewalk or a paved drweway located on public property 84 12.1m)! ' N Clearance under veranda, porch. deck. or balcony 12130cm), ' ' In accordance with current CSA 8149.1. Natural Gas and Propane Installation Code 2 In accordance with the current ANSI Z223. liNFPA 54. Nat,onal Fuel Gas Code +A vent shall not terrneste directly above a sklewak or paved driveway which is located between two single family dwellings and serves both dwellings $ Permitted only if veranda. porch, deck. or balcony S fully open on a minimum of two sides beneath the floor • Clearance in accordance with local installation codes and the requirements of the gas supplier a 3 feet (91cm) within a height of 15 feet (4.5m) above the meter 1 regulator assembly b 3 feet (91cm) above - it within 10 feet (3m) horizontally Regency Hertz:mini I4Z40E Gas Fireplace EFTA00301436 INSTALLATION 4" X 6-5/8" RIGID PIPE CROSS REFERENCE CHART ONLY Components from different Manufacturers may not be mixed. Not All Rigid Pipe components are available directly from FPI. Oescriptien Simpson Owed Wm pia SeIldrk Direst Terrr American Metal ProductsID AmOtIvial Died Meial-Fabm Sure Seel SecurRy Secure-Vent ICC Excel Med 8 Pipe Length-Galvanized 460VA-06 401-6 WA 406 SV4L6 TC-4DL6 8 Pipe Length-Black 460VA-069 40T-65 WA 4065 SV4L86 TC-40L6B 7- Pipe Length-Galvanized N/A WA 407 WA WA WA 7- Pipe Length-Week WA WA 4075 WA WA N/A 9" Pipe Length-Galvanized 46DVA-09 40T-9 WA WA WA WA 9" Pipe Length-Week 460VA-095 4DT.95 WA WA WA N/A 12' Plpe Length-Galvanized 46DVA-12 40T-12 4012 4012 SV4L12 TC-40L1 I2- Pipe Lengui-Black 460VA-125 40T-125 40125 40125 SV4L812 TC-II)Liti 18' Pipe Length-Galvanized 46DVA-18 407-18 4018 4018 SV4LA TC-40L18 1W Pipe Length-Black 46DVA-18B 40T-185 40185 40185 SV4LA TC-4DL 18B 24' Pipe Length-Galvanized 48WA-24 401-24 4024 4020 SV4L24 TC-40L2 24' Pipe Length-Black 460VA.245 401.245 40245 40245 SV4L524 TC-40L2B 36' Pipe Length-Galvanized 480VA-36 40T-36 4036 4036 5V4138 TC-40L3 36' Pipe Length-Black 46DVA-365 401-366 40366 40365 SV4L536 TC-40L36 48' Pipe Length-Galvanized 480VA-48 40T-48 0048 4048 SV4L48 TC-40L4 4W Pipe Length-Black 46DVA-486 401-48B 40486 40485 SV4L548 TC-40L46 60' Pipe Length-Galvanized 48WA-60 40T-60 WA N/A WA N/A EC Pipe Length-Black 460VA-606 401-60B N/A WA WA WA Adjustable Length 7 -IT-Galvanized WA WA N/A 4DAL WA TC-ODLT Adustabte Length T. I 0' -Black WA WA WA 4DAL5 WA TC.4DLTB Adjustable Length T -Galvanized WA WA 4D7A WA WA N/A Adusiable Length T'-Black WA WA 407AB WA WA NA Extension PO 8-1/t-Galvanized 460VA-08A WA N/A WA WA N/A Extension Pipe El-VT-Black 46DVA-OBAB WA N/A WA WA NA Adjustable Length It -Galvanized WA WA 4012A WA SVOLA12 N/A Ackosiable Length 12'-Slack WA WA 4012A WA SV4L5Al2 NA Extensko Pipe 16*-GaNailzed 460VA-16A WA N/A WA WA NIA Extension Pipe 16'-Black 46DVA-I6AB WA WA WA WA WA 45' El3ow-Galvantzed 46DVA-E45 407-EL45 4045L WA N/A TE-40E45 45' Wbow-5lack 460VA.E456 401-EL455 40T-EL45B VA WA TE-40E458 45' Elbow Swivel-Galvanized See 460VA-E45 N/A WA 41345L SV4E45 WA 45' Ebow Swwel.Black See 46DVA.E45B WA WA 4045L5 SV4EB45 WA 90' Elbow-Galvanized 460VA-E90 401-EL9OS 40TEL9OS N/A N/A TE-40E90 90' Ebow-Black 460VA.E936 40T-EL90S5 40T-EL90S5 WA SV4EBR90.1 TE-40E90B 90' Elbow. SwIvel.Galvantzed See 460VA-E90 N/A WA 40901. SV4E90-1 WA 90' Elbow. Swivel.Black See 46DVA.E9OB WA WA 4090L5 SV4E690-1 WA 90' Starter Elbow. Swivel-Gab/awed N/A N/A WA 4090A N/A WA Adaptor' WA WA WA 4090L WA WA Ceiling Support WA 407-CS 4DFSP 40SP SV4SD 7E-4DE45 Cathedtal Support Box 46DVA-CS 40T-CSS 401156 40RS SV4CSB TE-41)E4515 Wal Support/Band 46DVA-WS 407-WS1B 4DWS 4DWS SV4BM WA Ofiset Support 46CP/A.ES (MA . FPI) 40T-OS NSA WA SV4SU WA Wal Thanble-Black 46DVA-WT 407-WT 40W7 40W1 SV4FISM 7E-4DE90 Wal Trimble Suppcit/Ceiling Supped., 460VA•DC WA NSA NA SV4PF TE-40E90B Areal* Spacer 46DVA-FS 407-FS 4DFSP 4DFS SV4BF _ WA — Trim Pate-Back WA 4DT-TP 4DEPB 40CP SV4LA WA C Regency Horizon"' HZ40E Gas Fireplace EFTA00301437 INSTALLATION Description Simpson Deceived Pro* Selldrk Direct Temp" American Metal Products:ID Arnehwer Oita Metal-Fatd" suet Sod Security Secure-Were ICC Excel Circa Attc NtolatKin She 2' 46CNA.IS MAO FPI NrA 4DAIS12 WA SV4RSA TA Attic Insulation Shield - Cold °khakis 36" N/A N/A ODAIS12 N/A N/A TM-4AS Basic Horizontal Termination Kit (A) Disc. 4DT.HKA 4DHTK2 4W-1'MA SV-SHK NA Horizontal Termination Kit (B) 46DVA-KMA tOwind mai:fent; 401-ZIKB 4DHTK1 4DHTI(B SV-HK HA Vencal Terminatim Kil Ds. 4C.T.oKC 4DHTK fo:r7K SlbFK NA High Wind Verlical Cap 46DVA-VCH WA WA Ni'. WA TM-4VT nigh Wird Horizontal Cap 46DVA.HC NA TA TVACHT Horizontal Square Termination Cap See 46DVA-HC 4DT-HiSC 4DHC 4DHT SV4CHC-I TA-4MT Vented Termination Cap 461YVA.vC 4DT.FP/C 4DVC 4DVT SV4CGV.I TM-4V7 Storm Collar 46DVA-08A 4DT-SC 4DSC 4DSC SV4FC TA-SC Adjustable Flashing OM 24212 460VA-F6 4DT-ST t4 40125 405114 SV4STCI4 TF-4FA Adjustable Mashing 6/12-12/12 46DVA-FLA 4DT-ST36 4D355 4DST36 SV4STC38 TF-4F0 Vinyl &ding Standen 46DVA.VSS 4DT-VS NrA 4DVS SV4VS PA-VSS Vinyl Siding Shield Plate N/A 4DT-VSP N/A WA SV4VS N/A Snorkel Termination 14' 46DVA.SNKL TA WA IFA NIA T.4-43714 Snorkel Termination 36- N/A NIA WA WA WA 114-4S138 Redick!' Disk NA NA NR WA TA TM-4DS Extended Vertical Termination Cap WA WA N/A NM WA N/A Chimney Corweision Kt A (USA only) 46DVA.KCA Ni WA NrA TA TM-4CA6 Chimney Conversion Ki B (USA only) 46DVA-KCB WA N/A NIA WA T.4-4CA7 Chimney Corrmesion 10 C (USA only) 46DVA.KCC Na NrA WA NIA PARCAE, Chimney Conversion Kt Masonry (USA only) 46DVA10.4C WA WA NIA WA N/A Wal Fireslop 46DVA.V/FS Na NrA WA NIA TM-SIR Cando Flex Connectors 46DVARDF WA NfA N/A WA WA FPI 946-506P Vary Guard (Optimal) for AstroCap 948-206 Vinyl Siding Shield for Riser VeM Terminal 510.994 Rigid Pipe Adaptor (Must use with all rig° piping) 946-200P Vent Guard (Opting Ice Riser Vent Terminal 640-530:P Mae( Vent Terminal 948-523V AstroCap Horizontal Cap 946-605 Starter Calm Increaser C x 8-6/V to 5' x 8' 946.206 Vinyl Siding Standoff for AstroCap Note: When using Metal-Fab Site Seal Rigid Piping - please note that the Adaptor (400A) must be used in ccojundko wkh FPI Rigid Pipe Adaptor (510-994). Offset Pipe Selection: Use this table to determine offset pipe lengths. Pipe Length 0-) V x 6.5TVenting For SpOCille insItuctions on venting °deponents - visit the manulaclurers ivebsite ISIS below. RLYI L . / / / / I I ' I I Y I (X) Kee CY) 0- (0mm) 4-718- (124mm) 13-7/8' (340mm) Simpson Direct Vent Pro: 6" (152tivn) V (933mm) 16-1 /2- (419twn) Selkirk Direct-Temp: 9' (229mre) 10-L8- (257mm) 18-5/8" (473mm) American Metal Predicts 12- (3116mm) 12-1/C (3l 1mm) 20-3/4- (527mm) Metal-Fab Sure Seal: 24' (610mm) 20-5V (524mm) 29-1/8" (74Ornm) Se:Andy Secure Vent. — ' I i X 36- (914mm) 29- (737mm) 37-112- (953mm) Industrial Chimney Company: 48' ( I 21 ginvn) 37-7/16' (951mm) 45-15116' i1167mm) Note: Horizontal Leis DI vent must be love. or have a VC rise or every 1 fool of tort towards the letmimtlo Never anew the vent to MIdCwaws d - this could CALM high temperatures and may present a posstl fire hazard. Regency Horizon"' 14240E Gas Fireplace EFTA00301438 INSTALLATION VENT RESTRICTOR POSITION Vent restriction is required for certain venting installations. see the diagrams in the "Venting Arrangements' section to determine if they are required for your installation. The Vent Restrictor plate is located on the inside top of the firebox. To set the vent restriction as indicated in the venting arrangements diagrams, refer to the following instructions: 1) Remove the glass door - see instructions in this manual. 2) Remove the screws that hold the vent restrictor plate in place. 3) Adjust the vent restrictor plate to the required vent restrictor position as per the diagrams shown. 4) Once the vent restrictor plate is in the required position, secure with screws. 3.000 Set 0 (Factory set) VENT RESTRICTOR AT 3' 2000 I Set 1 VENT RESTRICTOR AT 2' 1500 u—kria-u Set 2 VENT RESTRICTOR AT 1.1/2' 1.000 Set 3 VENT RESTRICTOR AT 1" C Regency HorlzonTM HZ40E Gas Fireplace EFTA00301439 INSTALLATION VENTING INTRODUCTION The HZ40E uses the "balanced flue' technology Co-Axial system. The inner liner vents products of combustion to the outside while the outer liner draws outside combustion air into the combustion chamber thereby eliminating theneed louse heatedroom air for combustion and losing warm room air upthechimney. Note: These flue pipes must not be connected to any other appliance. The gas appliance and vent system must be vented directly to the outside of the building, and never be attached to a chimney serving a separate solid fuel or gas burning appliance. Each direct vent gas appliance must use its own separate vent system. Common vent systems are prohibited. VENTING ARRANGEMENT FOR HORIZONTAL TERMINATIONS The diagram shows all allowable combinations of vertical runs with horizontal terminations. using one 90° (two 45°elbows equal one 90° elbow). (Not including the starting 45 elbow at the flue collar when using rigid venting.) Note: Must use optional rigid pipe adapter (Part# 510-994) when using Rigid Pipe Venting Systems. Horizontal (Feet) 0 2 4 6 0 10 12 I I I ! I I Is 16 • 14I a.0 12 E 10 0 u_ a—0 .0 6 stu 2— > 0 • VENT RESTRICTOR SETTING: Vent restrictor lac ory se at Se 0. Refer to the 'Vent Restrictor Position" section for details on how to change the vent restrictor from the factory setting of Set 0 to Set 1 if required. Vent Restrictor on Set 1 36.114' (921mm) Ainimum Height Recpinnent 14 16 18 20 Note: For horizontal terminations the Regency Direct Vent Flex System may be used for installations with a maximum continuous vent length of up to 10 feet. If longer runs are required, rigid pipe must be used. • Maintain clearances to combustibles as listed in "Clearances" section • Horizontal vent must be supported every 3 feet. • Firestops are required at each floor level and whenever passing through a wall. • A vent guard should be used whenever the termination is lower than the specified minimum or as per local codes. • Flex system can only be used up to 10 feet - otherwise rigid venting must be used. Regency Horizonw HZ40E Gas Fireplace EFTA00301440 INSTALLATION HORIZONTAL TERMINATIONS FLEX VENT 4" X 6-7/8" These venting systems. in combination with the HZ40E Direct Vent Gas Fireplace, has been tested and listed as a direct vent heater system by Warnock Hersey/ Intertek. The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram in 'Exterior Vent Termination Locations" section. Regency. Direct Vent (Flex) System Termination Kits includes all the parts needed to install the 14240E using a flexible vent. FPI Kit # Length Contains: #946-513 2 Feet 1) 6.7/8" flexible outer liner (Kit length) 2) 4' flexible inner liner (Kit length) 3) spring spacers #946-515 4 Feel 4) thimble 5) AstroCap termination cap 6) screws 7) tube of Mill Pac #946-516 10 Feet 8) plated screws 9) S.S. screws #8 x 1.1/2' drill point Notes: 1) Liner sections should be continuous without any Joints or seams. 2) Only Flex pipe purchased from Regency" may be used for Flex installations 3) Horizontal vent must be supported every 3 feet. 4) Regency"Direct Vent System (Flex)Isonlyapproved for horizontal terminations. 5) Flex system can only be used up to a maximum continuous vent length of up to 10 feet. If longer runs are required, rigid pipe must be used. Wall Thimble AstroCar 4" dia. flue pipe Termination Cap 6-7/8" (Part# 946-523/P) 173mm) .5, dia. Flue pipe spring spacer Vent Guard (Part #946-506/P) 22 Regency Horizon"' HZ40E Gas Fireplace EFTA00301441 INSTALLATION HORIZONTAL TERMINATIONS RIGID PIPE 4" X 6-5/8" The minimum components required for a basic horizontal termination are: 1 Horizontal Termination Cap 1 45° Elbow 1 Rigid Pipe Adaptor (510-994) 1 Wall Thimble 1 Length of pipe to suit wall thickness (see chart) Wall thickness is measured from the back standoffs to the inside mounting surface of termination cap. For siting other than vinyl furring strips may be used. instead of the vinyl siding standoff, to create a level surface to mount the vent terminal. The Terminal must not be recessed into siding. Measure the wall thickness including furring strips. If a Vinyl Siding Standoff is required (it must be used with vin I siding), measure to outside surface of wall without siding and add 2 inches. r i,",,ii:I I I inhi l ETii .n li Wall Thickness (inches) Vent Length Required (inches) 4" • 5.1/2' 6' 7" • 8-1/2' 9' 10" - 11.1/2' 12" 9" - 14-1/2" 11" - 14-5/8' Adj. Pipe 1T - 23-1/2' 1r - 24' Adj. Pipe WARNING- Do not combine venting components from different venting systems. However use of the the AstroCar and FPI Riser is acceptable with all systems. This product has been evaluated by Intertek for using a Rigid Pipe Adaptor in conjunction with Duravenl Direct-Vent. Selkirk Direct-Temp. Ameri Vent Direct Venting, ICC Excel Direct and Security Secure Vent systems. Use of these systems with the Rigid Pipe adaptor is deemed acceptable and does not affect the Intertek WHI listing of components. Horizontal Termination Cap Vinyl Siding Standoff (Optional all Thimble • Adj.Pipe Length 4T Elbow Rigid Pipe Adapter When using Rigid Vent other than Simpson 0ura-Vent, 3 screws must be used to secure rigid pipe to adaptor. Vent Guard (Part #946-506/ The FPI AstroCapw and FPI Riser Vent terminal are certified for installations using FPI venting systems as well as Simpson Dura-Vent• Direct Vent. American Metal Products Ameri Vent Direct Vent. Security Secure Venr. ICC Excel. Selkirk Direct-Temp. AstroCari is a proprietary trademark of FPI Fireplace Products International Ltd. Dura-Vent® and Direct Vent are registered andfor proprietary trademarks of Simpson Dura-Vent Co. Inc. Regency Horizon"' 14240E Gas Fireplace EFTA00301442 INSTALLATION HORIZONTAL TERMINATIONS RIGID PIPE 4" X 6-5/8" The diagrams below shows examples of horizontal termination arrangements using one, two. or three 90, ebows (two 45° elbows equal one 90° elbow) 1) A maximum of three 90° elbows are permitted (not Including the starting 45°elbow at the flue collar when using rigid venting). 2) Minimum distance between elbows is 1 ft. (305mm). • Maintain clearances to combustibles as listed in the "Clearances" section. • Horizontal vent must be supported every 3 feet. • Firestops are required at each floor level and whenever passing through a wall. • Must use optional rigid pipe adaptor (Part# 510-994) when using rigid pipe vent systems. • A vent guard should be used whenever the termination is lower than the specified minimum or as per local codes. • Flex system can only be used up to 10 feet - otherwise rigid venting must be used. Straight Out Horizontal Venting Diagram 1 center of hole • Please note the minimum centerline for basic install shown above. Regency Horizon"' HZ40E Gas Fireplace EFTA00301443 INSTALLATION Horizontal Venting with Two (2) 90° Elbows One elbow = Two 45° elbows. Option V H + H1 Withtheseoptions. maximum A) 1' Min. 3' Max. total pipe length is 28 feet with minimum of 6 teel total B) 2' Min. 4' Max. vertical and maximum 8 feet C) 3' Min. 5' Max. total horizontal. D) 4' Min. 6' Max. Pleese note minimum 1 loot between 90° elbows is E) 5' Min. 7 Max. required. F) 6' Min. 8' Max. Restrictor Position Set 0 (factor)/ sening) Horizontal Venting with Three (3) 90° Elbows One 90° elbow = Two 45° elbows. Option H V Hatt+H2 With these options. maximum total pipe length is 28 feet with of 11 teat minimum total vertical and maximum 9 foet total horizontal. Plees, note minimum 1 loot between90°elbows Is required. A) 1' Max. 1' Min. 3' Max. B) 2' Max. 3' Min. 5' Max. C) 3' Max. 5' Min. 6' Max. D) 4' Max. 7' Min. 7' Max. E) 5' Max. 9' Min. 8' Max. F) 6' Max. 11' Min. 9' Max. H2 Restrictor Position Set 0 (lactory setting) Horizontal Venting with Two (2) 90° Elbows One elbow = Two 45° elbows. Option H V H4411 With these options, maximum total pipe Iength Is 28 feet with minimum of 8 feet total and maximum 8 feet total horizontal. Ppielaosoetnotmin betwnimg elbows is required. A) 1' Max. 1' Min. 3' Max. B) 2' Max. 2' Min. 5' Max. C) 3' Max. 4' Min. 6' Max. D) 4' Max. 6' Min. 7' Max. E) 5' Max. 8' Min. 8' Max. Restnctor Position - Set 0 (factory setting) Regency Horizon*" HZ40E Gas %oplas° 25 EFTA00301444 INSTALLATION Horizontal Venting with Three (3) 90° Elbows One 90' elbow= Tvo 450 elbows. Option V H V+V1 H+H1 With !hase options, maximum total pipe lenath is 28 feet with A) 2' Min. 1' Max. 3' Min. 4' Max. B) 3' Min. 2' Max. 4' Min. 5' Max. totaln uvrite rtlitc at r atenectl lriloVizimonilail.9 feet total Please note minimum I kun between 90' elbows Is requIred. C) 4' Min. 3' Max. 6' Min. 6' Max. D) 5' Min. 4' Max. 8' Min. 7' Max. E) 6' Min. 5' Max. 10' Min. 8' Max. F) 7' Min. 6' Max. 12' Min. 9' Max. Restnctor Position Set 0 (tadog setting) Regency Horizonn, HZ40E Gas Flreplace EFTA00301445 INSTALLATION VERTICAL TERMINATIONS RIGID PIPE 4" X 6-5/8" The minimum components required for a basic vertical termination are: Vertical Termination Cap 45° Elbow Rigid Pipe Adaptor (510.994) Ceiling Firestop Flashing Storm Collar Length of pipe to suit wall thickness (see chart) Galvanized pipe is desirable above the roofline due to its higher corrosion resistance. Continue to add pipe sections through the flashing until the height of the vent cap meets the minimum height requirements specified in Dia.4 or local codes. Note that for steep roof pitches. thevertical height must be increased. A poor draft, or down drafting can result from high wind conditions near big trees or adjoining roof lines. in these cases, increasing the vent height may solve the problem. Roof Pitch Minimum Vent Heigh Feet Meters flat to 7112 2 0.61 over 7/12 to 8/12 2 0.61 over 8112 to 9/12 2 0.61 over 9/12 to 10/12 2.5 0.76 over 10/12 to 11/12 3.25 0.99 over 11/12 to 12/12 4 1.22 over 12/12 to 14112 5 1.52 over 14/12 to 16/12 6 1.83 over 16,12 to 18/12 7 2.13 over 18,12 to 20/12 7.5 2.29 over 20/12 to 21/12 8 2.44 Vertical Terminal Storm Collar Flashing Ceiling Firestop WARNING. Do not combine venting components from different venting systems. However use of the the AstroCapw and FPI Riser is acceptable with all systems. This product has been evaluated by Intertek for using a Rigid Pipe Adaptor in conjunction with Duravent Direct-Vent. Selkirk Direct-Temp.Ameri Vent Direct Venting.ICC Excel Direct and Security Secure Vent systems. Use of these systems with the Rigid Pipe adaptor is deemed acceptable and does not affect the Intenek WHI listing of components. Pipe Length Rigid Pipe Adapter When using Rigid Vent other than Simpson Dura-Vent. 3 screws must be used to secure rigid pipe to adaptor. The FPI AstroCar and FPI Riser Vent terminal are certified for installations using FPI venting systems as well as Simpson Dura•VenP Direct Vent. American Metal Products Amen Vent Direct Vent. Security Secure Ventt. ICC Excel. Selkirk Direct-Temp. AstroCap1° is a proprietary trademark of FPI Fireplace Products International Ltd. Oura-Vent and Direct Venl are registered and/or proprietary trademarks of Simpson Oura.Vent Co. Inc. Regency Horizon,'" HZ40E Gas Fireplace EFTA00301446 INSTALLATION H VENTING ARRANGEMENT FOR VERTICAL TERMINATIONS Vertical Venting with One(1) 90° Elbows (1 - 90° 2 - 45°) Theshadedareainthediagramshowsallallowablecombinations of straight vertical and offset to vertical terminations, using one 90° elbow, with Rigid Pipe Venting Systems. Two 45° elbows equal to one 90° elbow. not including the starting 45° elbow at the flue collar. Vent must be supported at offsets. Minimum distance between elbows is 1 ft. (305mm). Maintain clearances to combustibles as listed In the "Clearances" section. Horizontal vent must be supported every 3 feet. m— a- 33 Firestops are required at each floor level and whenever passing through a wall. Must use optional rigid pipe adaptor (Part# 510.994) when using rigid pipe vent systems. Refer to the "Vent Restrictor Position" section for details on how to change the vent restrictor from the factory setting of Set 0 to Set 1 or Set 2 if required. 14 a — a — I — I — 2 — a Horizontal (Feet) a a a el I I I A Vert Rosinaor on E Vett Rostrictor on Sot 2 iazt,_ 4—I M. Maim." @Nad ppe between elbass 12'(306m n( Vent Rosinclor on Set I M. IC tat (cialerine lo conk** 11 ff I i t Regency Horizon"' HZ40E Gas Fireplace EFTA00301447 INSTALLATION VERTICAL TERMINATION WITH CO-LINEAR FLEX SYSTEM THE APPLIANCE MUST NOT BE CONNECTED TO A CHIMNEY FLUE SERV- ING A SEPARATE SOLID FUEL BURNING APPLIANCE. This appliance is designed to be attached to two 3" (76mm) co-linear aluminium flex running the full length of the chimney. See the 'Venting Arrangements Vertical Terminations' Section for minimum and maximum heights. Required Parts: Part # Description 946.529 Co-linear DV Vertical Termination Cap 948.305 3" Flex 35 ft. 946.563 Co-Axial to Co-LinearAdaptet Kit which contains the following: Co-linear Flex Adapter Outer Pipe Inner Pipe Adapter 510.994 Rigid Pipe Adaptor 46DVA-E45 450 Elbow Alternate Approved Caps 46DVA-VC Vertical Termination Cap 46DVA-VCH High Wind Cap 46DVA-GK r Co-linear Adapter with flashing Masonrychimneys may takevariouscontourswhichthe flexiblelinerwill accommodate. However. keep the flexible liner as straight as possible. avoid unnecessary bending. The Air Intake pipe must be attached to the inlet air collar of the termination cap. Co-linear DV Vertical Termination Cap # 946-529 A maximum of two certified joiner kits may be used per length. #948-305 35ft (11m) Exhaust Flue Outer Pipe with Kit# 946-563 Pipe Length N4 Rigid Pipe Adapter # 510-994 45° Elbow Inner Pipe Adapter with Kit# 946-563 Flex Liner Air Intake Co-Linear Flex Adapter with Kit# 946-563 Regency Horizon" HZ40E Gas Fireplace 29 EFTA00301448 INSTALLATION VERTICAL TERMINATIONS RIGID PIPE 4" X 6-5/8" • Two 450 elbows equal to one 90° elbow. Maximum of four 45° elbows allowed, not including the starting 45°elbow al the flue collar. • Vent must be supported at offsets. • Minimum distance between elbows is 1 ft. (305mm). • Maintain clearances to combustibles as listed in the "Clearances" section. • Horizontal vent must be supported every 3 feet. • Firestops are required at each floor level and whenever passing through a wall. • Must use optional rigid pipe adaptor (Part./ 510-994) when using rigid pipe vent systems. Vertical Venting with Two (2) 90° Elbows One 90' elbow = Two 45° elbows. Option V H V+V1 With these options. maximum total pipe length is 30 feet with vmeliliiienlaulmanodf rn6armtutomtal feel total horizontal. Please note minimum I loot between 90° elbows is required. A) i• min. 4' Max. 2' Min. B) 2' Min. 5' Max. 3' Min. C) 3' Min. 6' Max. 4' Min. D) 4' Min. 7' Max. 5' Min. E) 5' Min. 8' Max. 6' Min. Restrictor Position Set 0 (factory setting) Vertical Venting with Two (2) 90° Elbows One 90° elbow = Two 45° elbows. Option H + Ht V With theseoptions. maximum A) 2' Max. Z Min. total pipe length is 30 feet with minimum of 6 feet total vertical and maximum 6 feet total horizontal. Please note minimum I foot between 90° elbows is required B) 3' Max. a Min- C) 4' Max. 4' Min. D) 5' Max. 5' Min. E) 6' Max. 6' Min. For additional vertical venting with 2 x 90° elbows. refer to 'Rigid Pipe Venting Arrangements" Section. Restrictor Position Set 0 (factory setting) 30 Regency Horizon*" HZ40E Gas Fireplace EFTA00301449 INSTALLATION Vertical Venting with Three (3) 90° Elbows One 90° elbow = Two 45° elbows. Option H V H + H1 V + V1 With these options. max. total pipe length is 30 feet with min. of 11 feet total vertical and max. 7 feet total horizontal. Please note min. 1 loot b etween required. 90, elbows is A) t• Max. t• Mm. .5 Max. I .5 min. B) 2' Max. 2' Min. 4' Max. I 5' Min. C) 3' Max. 3' Min.' 5' Max. 7' Min. D) 4' Max 4' Min. E) 5' Max 5' Min. 61 Max. 9' Min. 7 Max. ' 11' Min. Restrictor Position Set 0 (factory setting) Vertical Venting with Three (3) 90° Elbows One 90, elbow= Two 45, elbows. Option V H + H1 V + V1 withthese options, max. total pipe length is 30feet with min. of 10 feet total vertical and max. 8 feet total horizontal. Please note min. 1 loot between 90° elbows Is required. A) Z Min. 3' Max. 4' Min. B) 3' Min. 4' Max. 6' Min. -- CF. 4. Mm. 5' Max. 7' Min. D) 5' Min. 6' Max. 8' Min. E) 6' Min. 7' Max. 9' Min. 10' Min F) 7' MunriMax. Resuictor Position - Set 0 (factory setting) Regency Horlzonm 11240E Gas Fireplace EFTA00301450 INSTALLATION Horizontal Distance (Feet) VENTING ARRANGEMENTS - VERTICAL TERMINATIONS with Co-linear Flex System for both Residential & Manufactured Homes into Masonry Fireplaces Vertical Height (fe 35— O 0 E E IF Vent Restrictor Set 2 r C • ao 35' (10.7m) Max. • x 2 • 7OSg I 1 1 I I I Horizontal Distance (Feet) Vent Restrictor Set 1 The shaded area in the diagrams show the allowable vertical terminations when using two- 3" co-linear aluminium flex and 4 x 6-5)8" rigid pipe. 35 Vertical Height (feet) CV 1 Ven Restrictor Set 2 8 E lV • • A --EE E Cl to 0 E 2 Combined max. of 16' M I I I I I I Horizontal Distance (Feet) • • Vent Resbictof Set 1 Regency Horizon"' HZ40E Gas Fireplace EFTA00301451 INSTALLATION UNIT INSTALLATION WITH HORIZONTAL TERMINATION 4" X 6-5/8" VENTING (Rigid Vent Systems) Minimum Vent Clearances to Combustibles ' Clearances noted below must be maintained: except when passing through a wall. ceiling of al the termination where the use of a firestop or wall thimble reduces clearance to 1 -112' (38mm). Horizontal Top' 3" (76mm)' Horizontal Side 2 " (51mm) Horizontal Bottom 2" (51mm) Vertical Vent 2" (51mm) Below are the recommended framing dimensions (inside measurements) for the 4" x 6-5/8' rigid vent terminations - for use with a firestop or wall thimble. Recommended Framed Opening Size Vent Size Framing Size ri" z 6 - 5/8' 10' x 10' Install the vent system according to the manufacturers instructions included with the components. 1) Set the unit in its desired location. Check to determine if wall studs or roof rafters are in the way when the venting system is attached. If this is the case, you may want to adjust the location of the unit. Rough in the gas preferably on the right side of the unit and the electrical (junction block is on the left side) on the left. 2) Direct Vent pipe and fittings are designed with special twist-lock connections to connect the venting system to the appliance flue outlet. A twist•lock appliance adaptor is required. 3) In conjunction with theApproved Vent system. install the adaptor after the unit is set in its desired location. Put abeadof high temperature silicone inside the outer section of the adapter and a bead of Mill Pack on the inner collar. Slip the adapter over the existing inner and outer flue collar. Fasten to the outer collar only with the 3 supplied screws (drilling pilot holes will make this easier). 4) Level the fireplace and fasten it to the framing using nails or screws through the top and side nailing strips. Female SE Locking • Lugs Male Pease> Lugs Diagram I 5) Assemble the desired combination of pipe and elbows to the appliance adaptor and twist-lock for a solid connection. Note: Forbestresultsandoptimumperfonnance with each approved venting system, it is highly recommended to apply "Mill-Pac•" sealant (supplied) to every Inner pipe connection. Failure to do so may result in drafting or performance issues not covered under warranty. Silicone (red RTV) is optional. Horizontal runs of vent must be supported every 3 feet (0.9meter). Wall straps are available for this purpose. 6) Mark thevanforasquare hole.-see chart to left for size. The center of the square hole should line upwith the center•lineof the horizontal pipe. Cut and frame the square hole in the exterior wall where the vent will be terminated. See diagram 2 for center line requirements. If the wall being penetrated is constructed of non-combustible material, i.e. masonry block or concrete, an 8" (203mm) diameter hole is acceptable. Note: a) The horizontal run of vent must be level, or have a 1/4 inch rise for every 1 foot of run towards the termination. Never allow the vent to run downward. This could cause high temperatures and may present the possibility of a fire. b) The location of the horizontal vent termination on an exterior wall must meet all local and national building codes, Diagram 2 7) Ensurethat the pipe clearances to combustible materials are maintained (Diagram 5). Install the termination cap. Note: if installing termination on a vinyl siding covered wall, a vinyl siding standoff or furring strips must be used to ensure that the termination is not recessed into the siding. Siding apply sealant to all four sides bolt Horizontal — 4— Top to Vinyl Standoff screws Vinyl siding standoff Wall Thimble (required) Diagram 5 The four wood screws provided should be replaced with appropriate fasteners for stucco. brick, concrete, or other types of sidings. 8) Beforeconnectingthehorizontal run of vent pipe to the vent termination, slide the Wall Thimble over the vent pipe. The wall thimble is required for all horizontal terminations. 9) Slide the appliance and vent assembly towards the wall carefully inserting the vent pipe into the vent cap assembly. It is important that the vent pipe extends into the vent cap sufficient6stance so as to result in a minimum pipe overlap of 1-1/4 inches (32mm). Secure the connection between the vent pipe and the vent cap. 10) install wall thimble in the center of the framed hole and attach with wood screws (Diagram 7). Diagram 7 Regency Horizon" HZ40E Gas Fireplace a EFTA00301452 INSTALLATION UNIT INSTALLATION WITH HORIZONTAL TERMINATION 4" X 6-518" VENTING (Flex Vent Systems) Minimum Vent Clearances to Combustibles • Clearances noted below must be maintained: except when passing through a wall. ceiling or at the termination where the use of a frestop or wall thimble reduces clearance to v. (25mm). Horizontal Tor 3" (76mm)" Horizontal Side 2 " (51mm) Horizontal Bottom 2" (51mm) Vertical Vent 2" (51mm) Below are the recommended framing dimensions (inside measurements) or the 4" x 6.5/8" rigid vent terminations - for use with a firestop or wall thimble. Recommended Framed Opening Size Vent Size Framing Size e x 6 - 5/8' 10" x 10' 1) Locate the unit in the framing, rough in the gas (preferably on the right side of the unit). Locate the centerline of the termination and mark wall accordingly. Cut an square hole in the wall - see chart (inside dimension). Note: If Installing termination on a airline coy- gyed wall. a vinyl sidina standoff or vinyl 1111011811llizamustlausgsltoensure that the termination is not recessed into the siding. 2) Level the fireplace and fasten it to the framing using nails or screws through the nailing strips. 3) Assemble the vent assembly by applying Mill Pacto the inner flue collarof thelermination and slipping the inner flex liner over it at least 1.3/8" (35mm). Fasten with the 3 screws (drilling pilot holes will make this easier). Apply Mill Pac or high temperature silicone to the outer flex pipe and slip it over the outer flue collar of the vent terminal at least 1.3/8"(35mm) and fasten with the 3 screws. NOTE: Horizontal sections must be supported at Intervals not exceeding 3 feet (0.9 meter). (Flame picture and performance will be affected by sags In the liner). 4) Separate the 2 halves of the wall thimble and securely fasten the one with the tabs to the outside wall making sure that the labs are on top and bottom. Fasten the other thimble half to the inside wall. The thimble halves slip inside each other and can be &gusted for 2 x 4 or 2 x 6 walls. 5) Slip the assembled liner and termination assembly through the thimble making sure the termination cap faces up (there are markings on the cap indicating which way is up). This will position the termination cap with proper down slope for draining water. Fasten the cap to the outer wall with the 4 supplied screws. 6) Pull the centre inner and outer Ilex liner out enough to slip over the flue collars of the fireplace. (You may wish tocutthe liner shorter to make it more workable.) Do not bend liner more than 90'. The liners must slip over the collars a minimum of 14/8". 7) Apply Mill Pac over the fireplace inner flue collar and slip the inner flex liner down over it and attach with 3 supplied screws. 8) Do the same with the outer flue collar and outer flex liner. 9) Apply a bead of silicone between the thimble and termination and around the outer edge of the terminal al the wall in order to keep the water out. IMPORTANT: Do not locate termination hood where excessive snow or ice buildup may occur. Be sure to check vent termination area after snow falls. and cleat to prevent accidental blockage of venting system. When using snow blowers, make sure snow is not directed towards vent termination area. ASTROCAP DIMENSIONS (91W5231P) Screws 4" (102mm) dia. flue pipe (3 per ly with spring spacer connection) N 4. r 1 II 6-7/8" (173mm) dia. air intake Wall Thimble 2 pieces (10" (254mm Outer Diameter) Termination Cap Screws (4 per connection) Regency Horizon"' HZ40E Gas Fireplace EFTA00301453 INSTALLATION UNIT INSTALLATION WITH VERTICAL TERMINATION 4" X 6-518" VENTING (Rigid Vent Systems) 1) Maintain the 1.172" clearances (air spaces) to combustibles when passing through ceilings, walls, roofs, enclosures, attic rafter, or other nearby combustible surfaces. Do not pack air spaces with insulation. 4IFF Check 'Venting' Sections for the maximum vertical rise of the venting system and the maximum horizontal offset limitations. 2) Set the gas appliance in its desired location. Drop a plumb bob down from the ceiling to the position of the appliance flue exit, and mark the location where the vent will penetrate the ceiling. Drill a small hole at this point. Next, drop a plumb bob from the roof to the hole previously drilled in the ceiling. and mark the Die giaM 1 spot where the vent will penet ate the roof TI 3) A Firestop spacer must be installed in the floor or ceiling of every level. To install the Firestop spacer in a flat ceiling or wall, cut a 10 inch square hole. Frame the hole as shown in Diagram 2 and install the firestop. Note: All vertical terminations are vented using 4" x 6-5/8" venting and rigid pipe adaptor #510-994. 11Y(254nun) —1\ souare hole framing firestop spacer Diagram 2 4) Assemble the desired lengths of pipe and elbows. Ensure that all pipes and elbow con- nections are in the fully twist-locked position and sealed. Female Locking Lugs s cgke.coll Male Locking Lugs NOTE: For best results and optimum perform- ance with each approved venting system, It is highly recommended to apply"Mill-Pac" sealant (supplied) toevery Inner pipeconnectlon. Failure to do so may result In drafting or performance Issues not covered under warranty.Silicone(red RTV) is optional. 5) Cut a hole in the roof centered on the small drilled hole placed in the roof in Step 2. The hole should be of sufficient size to meet theminimum requirements for clearance to combustibles of 1.1/2'. Slip the flashing under the shingles (shingles should overlap half the flashing) as per Diagram 3. Diagram 3: The upper half Mho flashing is installed under the roofing material and not nailed down until the chimney is installed. This allows for small adjustments. 6) Continue to assemble pipe lengths. Note: II an offset is necessary in the attic to avoid obstructions, it is important to support the vent pipe every 3 feet. to avoid excessive stress on the elbows. and possible separation. Wall straps are available for this purpose. Galvanized pipe is desirable above the moans due to its higher corrosion resistance. Continue to add pipe sections through the flashing until the height of the vent cap meets the minimum height requirements specified in Dia. 4 or local codes. Note that for steep roof pitches, the vertical height must be increased. Apoorctraftordown drafting can result from high wind conditions near big trees or adjoining roof lines, in these cases, increasing the vent height may solve the problem. Diagram 4 Roof Pitch Minimum Vent Height Feet Meters flat to 7/12 2 0.61 over 7/12 to 8/12 2 0.61 over 8/12 to 9/12 2 0.61 over 9/12 to 10112 2.5 0.76 over 10/12 to 11/12 3.25 0.99 over 11/12 to 12/12 4 1.22 over 12/12 to 14/12 5 1.52 over 14/12 to 16/12 6 1.83 over 16/12 to 18/12 7 2.13 over 18/12 to 20/12 7.5 2.29 over 2(1/12 to 21/12 8 2.44 7) Ensure vent is vertical and secure the base of the flashing to the roof with roofing rails, slide storm collar over the pipe section and seal with a mastic. 8) Install the vertical termination cap by twist- locking it. Note: Any closets or storage spaces. which the vent passes through must be enclosed. Regency Horizonm 14240E Gas Fireplace EFTA00301454 INSTALLATION HZ40E-NG1 SYSTEM DATA Min. Supply Pressure 5" WC (1.25 kpa) Manifold Pressure 3.5" WC (0.87 kpa) Orifice Size 440 DMS Maximum Input 26,000 Btu'h (7.61 kW) Minimum Input 18,000 Btu/h (5.28 KW) HZ40E-LP1 SYSTEM DATA Min. Supply Pressure 11" WC (2.73 kpa) Manifold Pressure 10" WC (2.49 kpa) Orifice Size 453 DMS Maximum Input 25.500 Btuth (7.47 kW) Minimum Input 21.000 Btuth (6.15 KW) HIGH ELEVATION This unit is approved for altitude 01o4500 ft. (CAN.' 2.17-M91). GAS LINE INSTALLATION Since some municipalities have additional local codes it is always best to consult with your local authorities and the CAN/CGA 8149 installation code. For USA installations follow local codes and/or the current National Fuel Gas Code. ANSI Z223.1. When using copper or flex connectors use only approved fittings. Always provide a union so that gas lines can be easily disconnected for servicing. Flare nuts for copper lines and flex connectors are usually considered to meet this requirement. NOTE: A shutoff / dante valve should be sup- plied in or near the unit (or as per local codes) for ease of servicing this appliance. IMPORTANT: Always cheek for gas leaks with a soap and water solution or gas leak detector. Do not use open flame for leak testing. Pilot Ignitor PILOT ADJUSTMENT Periodically cheek the pilot flames. Correct flame pattern has two strong blue flames: 1 flowing around the flame sensor and 1 flowing across the burner (it does not have to be touching the burner). Burner o o 000 00 00 000oo001t000oo00 Flame Sensor Note: If you have an Incorrect flame pattern, contact your Regency' dealerfor further Instructions. Incorrect flame pattern will have small, probably yellow flames, not coming into proper contact with the rear burner or flame sensor. GAS PIPE PRESSURE TESTING The appliance must be isolated from the gas sup. ply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig. (3.45 kPa). Disconnect piping from valve at pressures over 112 psig. The manifold pressure is controlled by a regulator built into the gas control, and should be checked at the pressure test point. Note: To properly check gas pressure, both inlet and manifold pressures should be checked using the valve pressure ports on the valve. 1) Make sure the unit is in the "OFF' position. 2) Loosen the 'IN" and/or "our pressure tap(s). turning counterclockwise with a 118" wide flat screwdriver. 3) Attach manometerto*IN"androCOUT pressure tap(s) using a 5116" ID hose. 4) Turn the unit on with the remote or wall switch 5) The pressure check should be carried out with theunit burning and 'besetting should be within the limits specified on the safety label. 6) When finished reading manometer. turn off the unit. disconnect the hose and tighten the screw (clockwise) with a 118' flat screwdriver. Note:Screw should be snug. but do not over tighten. 880 S.I.T. VALVE DESCRIPTION 1) Pilot adjustment 2) Outlet Pressure Tap 3) Inlet Pressure Tap 4) Pilot Outlet 5) Main Gas Outlet 6) Main Gas Inlet 2 AERATION ADJUSTMENT The burner aeration is factory set but may need adjusting due to either the local gas supply or altitude. Open the air shutter for a blue flame or close for a more yellow flame. Minimum Air Shutter Opening: NG I/8" LP Note: Any damage due to carboning resulting from improperly setting the aeration controls is NOTcovered under warranty. 0 Regency Horizon"' HZ40E Gas Fireplace EFTA00301455 INSTALLATION AC POWER ADAPTOR INSTALLATION (FOR SUREFIRE SYSTEMS) An optional AC power adaptor may be Installed as a constant power source for the SureFire system. IMPORTANT: Recommend removing the 4-AA batteries in the SureFire receiver. This will avoid battery leakage and power drainage. 4-AA Battery pack may be reinstalled into receiver during power outages. NOTE: For all Gas Fireplaces 120 volt power must be brought to the receptacle box inside the bottom of the firebox (provided with the unit). All Freestanding Gas Stoves & Gas Inserts will need a receptacle box located outside near the unit so that the AC Power Adaptor can be plugged in. INSTALL AC ADAPTOR WITH SUREFIRE WALL RECEIVER SWITCH ONLY - (WITHOUT REMOTE) 1) Locate-DC Supply" tag on wire harness. For location in unit 2) Connect the male end from AC adaptor to the female end see remote installation page in owners manual. tagged -DC Supply" on wiring harness in unit. 3) Plug AC adaptor into 120V wall outlet (or into 120V receptacle if installed inside the gas fireplace firebox). 4) Neatly tuck any loose AC Power Adaptor wires neatly underneath / inside the appliance. Note: Ensure that wires do not touch the underside of the firebox (keep wires away from the heat as much as possible). INSTALL AC ADAPTOR WITH SUREFIRE PROFLAME GT / GTM REMOTE 1) Connect the male end of the AC adaptor to the female end of the wire adaptor (supplied with AC adaptor) together as shown . Wire adaptor AC adaptor 2) Locate FCM COM connector on the Remote wire harness - see manual for location in unit. FCM -COM 3) Plug in wire adaptor to FCM COM connector - be careful not to damage ends. This only fits one way. AC adaptor wire adaptor FCM - COM 4) Plug AC adaptor into 120V wall outlet (or into 120V receptacle if installed inside the gas fireplace firebox). 5) Neatly tuck any loose AC Power Adaptor wires neatly underneath / inside the appliance. Note: Ensure that wires do not touch the underside of the firebox (keep wires away from the heat as much as possible). Regency Horizon'" HZ40E Gas Fireplace EFTA00301456 INSTALLATION WIRING DIAGRAM This heater does not require a 120V A.C. supply for operation. In case of a power failure. the burner switch and the optional remote control/thermostat will continue to operate. However. a 120V A.C. power supply is needed for the taniblower operation. (Do not cut the ground terminal off under any circumstances.) NOTE: Even if the fan Is not purchased with the unit, it Is still a good Idea to bring power to the receptacle box (provided with the unit) in case the Ian Is Installed at a later date. PROFLAME SYSTEM GT Optional AC Adaptor 0.564.860 High Temperature 1125E ) AMC Power A00004 Optional AC Adaptor I 0.564.8.50 High Temperature (HST) AGOG Power Ad40 44 885 POW. Sworn Coregurabon 886 GMT %Ste Daarem Swarms"' Swtth IMIralnal• 0.564 302 Pradess INC Beard 0.6setitt2 VC Wee Hsenees Ammar s(das. Piot Gym a CHOI Setts PROFLAME SYSTEM GTM Proterne System Corisstraters 885611AF wre Dasgrats MILE- StreFtre". Switch CAUTION: Label all wires priori° disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. -E4.1E ,M# 5 ae VIre Harress Cr 0 554 9/ 2 0ncluclors %a CA-4 CRAM Swath) Wear Clicirtel• - • Prcasgrealerd Caution: Ensure that the wires do not touch any hot surfaces and are away from sharp edges. Regency Horizon"' HZ40E Gas Fireplace EFTA00301457 NSTALLATION PROFLAME SYSTEM GTMF WITH OPTIONAL FAN %SASSO Mon P L --Fa4=90: ) Proflame System Configuration 885 GTMF Wye Diagram SureForems Switch tr—riti 0 0 O 0.584.523 0.584.905 GTMFS Vilna Meows. DIO 0 a 0564.1 I Fan °card Module Neutral 120V AC Live 60 Hz 0.584.912 DFC Wire HarnessAssembly (Includes Plot Gin0 8 CPUIPI Switch) Sera Electrode Prc8ame DFZD2doere 0584. Black White Ground 'Green _ Black Black Black ®a Groundis I Fan Fan Thermodisc (normally open) Caution: Ensure that the wires do not touch any hot surfaces and are away from sharp edges. CAUTION: Label all wires priorto disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Regency Hodzonm 14241)E Gas Fireplace EFTA00301458 INSTALLATION Wire Nuts 14 AWG wire 'Wire Ciampi *Receptacle Box inside stove 'Receptacle (dedicated use by stove fan only) Copper Ground) 120 Volts White Deutra11_, 60 Hz Black jHot)___ 14 AWG wire OPTIONAL FAN WIRING DIAGRAM WITHOUT PROFLAME GTMF SYSTEM Lockwasher Star washer #8 Ground Lug (for mobile home) Fan ground wire L Electrical Connection Alternative Scheme "A", Power at Stove Wall Junction Box `Speed Control • Switch with lead wires (Regency) Neutral Black White Live "Green 120VAC Ground 60 Hz Black Ground Fan Black 0 Black Red Fan Thermodisc (normally open) Electrical Connection Alternative Scheme "B", Power at Switch Wall Junction Box ----- - - - - 'Speed Control Switch with lead wires Black (Hot) 120 Volts WhiteiNesitraiL 60 Hz CCalittGt0urAL__,_ + __ Wire • = supplied with fan kit Other parts are to be supplied by electrician or installer Wire Nuts S P -14 AWG wire *Receptacle Box inside stove 'Receptacle (dedicated use by unit Ian only) Black •_ S,mpnd ,1 iii till I ll 'Wire Clamp111 Caution: Ensure that the wires do not touch any hot surfaces and are away from sharp edges. CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. 40 Regency Horizon"' HZ40E Gas Fireplace EFTA00301459 INSTALLATION Optional REMOTE CONTROL Use the Regency' Remote Control approved for this unit. Use of other systems may void your warranty. The remote control comes with a hand held transmitter. *Profiame GT remote control 946-700 RF remote. ONIOFF Thermostat. ON/OFF Flame Control Large blue backlit LCD screen with temperature display receiver. 'Proflame GTM remote control 946-701. RF remote. ONIOFF Thermostat. ON/OFF Flame Control Large blue backlit LCD screen with temperature display receiver. nProflame GTMF remote control 946.702. RF remote. ONIOFF Thermostat. ON/OFF Flame Control ON,OFF fan control with 3-stage adjustment. Requires a fan (if not included). to be installed for fan function to operate. 'Must also chose one of the following which enables the flame to be turned down using the remote control: 'Modulator Surefire NG 946.693 'Modulator Surefire LP 946-694 Large blue backlit LCD screen with temperature display receiver. RECEIVER WALL SWITCH (Included with Unit) 1) Run the supplied 10' of the wire harness through the right or left side gas inlet opening- connect the ONIOFF wire harness. Be careful not todamage wire. 2) Choose a convenient location on the wall to install the receiver and the receptacle box (protection from extreme heat is very important). Run wires from the fireplace to that location. 3) Connect the wire to the receiver wall switch and install into the low voltage receptacle box. Regency Horizon"' HZ40E Gas Fireplace gal EFTA00301460 INSTALLATION WALL MOUNT ON / OFF SWITCH AND BATTERY COMPARTMENT INSTALLATION AND/OR RECEIVER INSTALLATION REQUIRED FOR ALL INSTALLATIONS - INCLUDING PROFLAME REMOTE CONTROLS JMPORTANT INSTAI I ATION NOTE. The Receiver must be placed inside the supplied (Low Voltage) junction type wall box and installed into the wall only. DO NOT INSTALL WITHIN THE CONFINES OF THE FIREPLACE. Remote Receiver Installation 1. Install the low voltage junction box to the framing, at desired location within 10 ft. from fireplace. 2. Feed the 12 pin connector through the opening at back of junction box. 3. Connect the 12 pin connector to the back of the receiver. 4. Install the Receiver in the Low Voltage Junction box. 5. Insert the 4 AA type batteries in the battery compartment with the correct polarity. 6. Place the slider into the cover plate. 7. Put the Receiver switch in the "OFF position, to allow correct lineup for slider switch. 8. Make sure the Receiver and cover plate words `OW and "Ur are on the same side. 9. Align the slider with the switch on the Receiver and couple the switch into the slider. 10. Align the screw holes. 11. Using the two (2) screws provided secure the cover plate to the Receiver. Optional Proflame Receiver Rumples WA Plant 10 ft. wire harness with 12 pin connector Low Voltage Junction Box Slider Switch "1449// Plate J-Box Receiver Diagram 1 Regency Horizon"' HZ40E Gas Fireplace EFTA00301461 INSTALLATION GTMF REMOTE INSTALLATION 120 VoltAC power is needed for the fan. The fan can be hard wired if desired. The receptacle box should be Installed on the right hand side of the unit by a qualified electrician. The neutral (wider) slot of the polarized receptacle should be at the top. Unit must be grounded at all times. Do not cut the ground terminal off under any circumstances. Note: Follow instructions below -if unit has not yet been installed -otherwise skip to existing installtions section. 1) Remove 8 screws to remove front access panel. 2) Remove 2 top screws and loosen 2 bottom screwsto remove side access panel. 3) Install fan control module (FCM) into bracket on the Inside of the panel. plug the (FCM) into the outlet in the unit - reinstall the panel with 4 screws from step 2. 4) Proceed to Step 11. INTO EXISTING INSTALLATIONS 1) Shut off the gas and power supply to the unit. 2) Remove the faceplate or door frame - see instruction in manual. 3) Remove the glass door. a) Remove the 3 screws shown below at the bottom of the glass door. b) Swing the door out 45° from the bottom and lift up and out. 4) Remove the inner panels - reverse of 'Inner panel installation' in the installation manual. 5) Remove the burner tray cover by lifting up and out as shown below. T • Prior to removing burner - remove crystals, pebbles, spa stones and inner panels - if installed. Regency Horizon"' HZ4OE Gas Fireplace a EFTA00301462 INSTALLATION 5) Loosen 2 screws at the back of the burner to release it. 6) Remove the burner by sliding it to the right - then lift out. 7) Remove the left access plate by removing 8 screws - see locations below. 8) Once the top panel is removed - the left side panel will be accessible. Remove 3 screws from the left side access panel In locations shown below. Note: Some components have been removed for illustration purposes. 9) Install the fan control module (FCM) through the opening created by the removed loft side access panel. Left side access 10) Install the fan control module (FCM) into the bracket as shown below. 0 Regency Horizon"' HZ40E Gas Fireplace EFTA00301463 INSTALLATION 11) Locate the digital firebox control box. 12) Plug the fan power cord Into the fan control module in the outlet marked fan. Plug in the FCM wire (from the digital firebox control box wire har- ness) into the location on the fan control module marked com 13) See Proflame remote instructions for coding remote to receiver as well as operating instructions. 14) Reverse steps 2-1 for new installations. Reverse steps 8 - 1 for existing installations. Regency Horizon"' HZ40E Gas Fireplace EFTA00301464 INSTALLATION OPTIONAL FAN INSTALLATION 120 Volt AC power is needed for the fan switch and blower. The fan can be hard wired if desired. The receptacle box should be installed on the left hand side of the unit by a qualified electrician. The neutral (wider) slot of the polarized receptacle should be at the top. Unit must be grounded at all times. Do not cut the ground terminal off under any circumstances. Follow these instructions before the initial installation into the framing. If installing the optional fan into an exiting installation • follow instructions on the next two pages. 1) Remove lower front face nailing strips (2 screws per nailing strip). 2) Remove 8 screws to remove front access panel. 3) Slide the fan assembly through the front access panel • slide all the way back to the back of the two tabs. Tabs 4) Secure the fan to the floor of the unit with 2 screws. in locations show below. 5) Connect one of the black wire to the Black wires from the power cord. (light blue connector). Connect the other end to one spade on the ther- modisc. 6) Connect the red wire end to the other open spade one the thermodisc. Connect the other end of the red wire to the black wire from the fan motor. 7) Connect the white wire from the fan motor to the black wire on the power cord.(dark blue connector). 8) Slide in the thermodisc to the clip in the location shown below. Thermodisc dip 9) Secure the ground wire from the fan assembly, also secure the ground wire from the power cord to the stud on the back left near the fan. 10) Plug the fan into the receptacle located in the lower left front corner at the base of the unit. NOTE: If installing the fan with a GTMF remote • please see GTMF remote instructions in the manual. TO REMOVE THE FAN 1) Turn the power off. 2) Reverse the above instructions. Maintenance: The sealed bearings are lubricated, there is no need to lu- bricate them further. (Extra lubricant will cause more lint and dust buildup - causing the bearings to prematurely fail). Regular cleaning and vacuuming of the fan area will add to the life of the motor. IMPORTANT: ese fans collect a lot of dust from within your home. Ensure you maintain these fan motors on a regular basis by vacuuming he fan blades and housing using a soft brush nozzle. a Regency HorlzonTM HZ40E Gas Fireplace EFTA00301465 INSTALLATION OPTIONAL FAN INSTALLATION - INTO EXISTING INSTALLATIONS 120 Volt AC power is needed for the fan switch and blower. The fan can be hard wired if desired. The receptacle box should be installed on the left hand side of the unit by a qualified electrician. The neutral (wider) slot of the polarized receptacle should be at the top (see page 41 for wiring diagram). Unit must be grounded at all times. Do not cut the ground terminal off under any circumstances. 1) Shut off the gas and power supply to the unit. 3) Remove the faceplate or door frame by lifting it up oft the glass door. Faceplate (4pc style shown) 4) Remove the glass door. Glass Door a) Remove the 3 screws shown below at the bottom of the glass door. b) Swing the door out 45° from the bottom and lift up and out. 5) Remove the inner panels - reverse of inner panel Installation' in the installation manual. 6) Remove the burner tray cover by lifting up and out as shown below. • Prior to removing bumer - remove crystals, pebbles, spa stones and Inner panels - if installed. 7) Loosen 3 screws at the back of the bumer to release it. — 1 _ I 'Cl 8) Remove the bumer by sliding it to the right - then lift out. 9) Remove the left access plate by undoing the 8 screws - see locations below. Location of screws on access plate 10) Remove the left access plate by undoing the 8 screws - see locations below. Regency Horizon*" HZ40E Gas Fireplace EFTA00301466 INSTALLATION 10) Maneouver fan through left access panel opening. 11) To complete fan Installation - follow steps 2- 7 on previous page. NOTE: The right access panel wasremoved to allow easier access to secure the right screw on the fan base. 12) Reverse steps 9-1 to complete install. C Regency Horizon"' HZ40E Gas Fireplace EFTA00301467 INSTALLATION INNER PANEL INSTALLATION Handling Instructions Black Enamel Panels • Black Enamel panels must be inspected for watches and dimples prior to installation. All claims to be recorded at this time. Claims for damage after installation will not receive consideration. • Black Enamel panels will discolor a little during normal operation. This is normal and should not be considered a defect. * Al hand and finger marks MUST be cleaned off with a soft cloth. Use an ammonia based cleaner (ie. glass cleaner) to remove any fingerprints before applying heat to the unit. Failure to do this will result in bum stain on panels which you will be unable to remove. Not protected by product warranty. 1) Remove the faceplate and glass door it already installed • see manual for instructions. 2) Remove 4 screws to remove top heat deflector. 3) Remove installed factory panels. Loosen 2 screws (do not remove) on panel clip securing side panel. Slide panel dip down away from screws. Remove side panel. panel clap 4) Repeat on opposite side. 5) Remove back panel. 6) Install the back enamel panel first. Tilt the panel lanyard • position the bottom of the panel first. Use care not to scratch or mar the panel on the pilot shield. 7) Install the loll side enamel panel • secure in position with the panel clip and two tighten two screws loosened in step 2, as shown in the diagram below. 8) Install the right side enamel panel - secure in position with the panel dip and two screws loosened in step 4. 9) Reinstall heat deflector. 10) Reinstall glass door • reinstall faceplate. I — MI Final /naafi Regency HorizonTM HZ40E Gas Fireplace LI EFTA00301468 INSTALLATION GLASS CRYSTALS OR OPTIONAL CERAMIC STONES INSTALLATION ON BURNER Evenly spread the Glass Crystals or optional Ceramic Spa Stones or Volcanic Stones over the burner. Ensure the crystals (or stones) do not ovedap too much as this wi effect the flame pattern. IMPORTANT NOTE: Onlythe supplied approved Glass Crystals and Ceramic Spa/lava Stones are to be used with these fireplaces. Use of any other type of glass crystals or stones can alter the tilts performance. any damage caused by the use of any unapproved glass or stones will not be covered under warranty. When using Ceramic Spa/ Lava Stones DO NOT cover burner ports or riot light that lead to pilot flame. Ensure the crystals or stones do not overlap excessively as this will effect the flame pattern. BURNER PACKAGES Unit •Glass Crystals Ceramic Spa / Volcanic Stones HZ54E 1 HZ54EPV 3 lbs 1 lb Glass + 2 packages (140 spa stones) HZ42 / I4Z42E I HZ40E 2 lbs I lb Gass • 1 package (70 spa stones) HZ42ST / HZ42STE HZ42STEPV 2 lbs 1 lb Glass + 1 package (70 spa stones) HZ30E •• 1 lb I lb Glass + 1 package (70 spa stones)•• HZI234E ••• 3141b 3/4 ti Glass + 1 package 70 spa stones)••• HZI390E/ HZ1390EB • 7 lbs (4 lbs burner + 3 lbs firebox) 2 lb Glass + 1 package (70 spa stones) / 2 lb Glass + 1 package (volcanic stones) HZI540EB • 8 Ds [4 lbs burner + 4 lbs firebox] 21b Glass +1 package (70 spa stones)/ 2lb Glass + 1 package (volcanic stones) HZO424-1ZO42 (AUS) 3 lbs Not Approved L6765 1 lb 1 package = (70 spa stones) P33S1233SE •— 1 lbs I package = (70 spa stones)— PTO3r/ Plateau Series 10 Ds Not Approved PTO60- 20 lbs Not Approved U32S / U32SE 1 lb 1 package = (70 spa stones) E335 1 lb I package = (70 spa stones) NOTE: • Glass Crystals are available in llb and 5Ib bags. All units come standard with Cobalt Blue glass crystals except: • HZO42 comes with Copper glass crystals. • HZI390E. HZI390EB. HZ1540EB. PTO30. PTO60 8 Plateau Series do NOT include glass crystals with units. Must purchase separately. • 1 Ceramic Spa stone package contains 70 stones. Recommended - use only 40 of the 70 ceramic stones on the HZ30E burner. Recommended - use only 24 of the 70 ceramic stones on the HZ1234E burner. •••• Recommended - use orgy 50 of the 70 ceramic stones on the P33S/P33SE burner. Glass Crystals shown on Burner For Units HZ54E. HZ54EPV. HZ42ST. HZ42STE. HZ42STEPV. HZ1234E. HZ42E. HZ42. HZ40E. HZ30E. HZO42. HZO42 (AUS) P7O30. PT060 Plateau Series only Glass Crystals shown on Burner For units P33.S. P33SE. L676S. U328. U32SE. E33S only 111 Glass Crystals shown on Burner and Firebox Floor For Units HZ1.390E. HZI390EB. HZI540EB only -1Zelitgra'terillififtralltallisam• Optional Ceramic Spa Stones + Glass Crystals shown on burner. For Units HZ54E. HZ54EPV. HZ42ST. HZ42STE. HZ42STEPV. HZ1234E. HZ42. HZ42E. HZ40E. HZ30E only Optional Ceramic Spa Stones shown on burner. For units P33aP33SE L676S. U325. U32SE. E33S only Regency HorlzonTM HZ40E Gas Fireplace EFTA00301469 INSTALLATION OPTIONAL PEBBLE / CRYSTAL INSTALLATION FOR FIREBOX BASE Firebox (Around Burner) Packages Unit Glass Crystals Pebbles HZ54E / HZS4EPV 6 lbs 2 packages (6 x bags pebbles) H242/ HZ42E / H240E 5 les 2 packages (6 x bags pebbles) HZ42817H242STEMZ42STEPV 5 lbs 2 package (6 x bags pebbles) HZ30E 2 les I package (3 x bags pebbtes) HZI540EB 4 lbs 1.5 packages (4 x bags pebbles) HZI390e HZI300ES 3 les I package (3 x bags pebbtes) HZI234E 2 lbs 1 package (3 x bags pebbles) 82042 / HZ042 (AUS) 3 les I package (3 x bags pebtores) P335 / P33SE 3 lbs I package (3 x bags pebbles) U32S I U32SE 3 les 1 package (3 x bags pebbles) E338 3 lbs I package (3 x bags pebbles) There are 2 optional packages to choose from to cover the firebox base: 1) Natural River Pebbles 2) Glass Crystals (4 colors available) Spread the pebbles ? crystals evenly on the exposed base of the firebox. Pebbles are Hat to be placed anywhere on the burner or over top of the Glass Crystals or optional Ceramic Spa Stones. IMPORTANT NOTE: Cray the supplied and approved pebbles/glass crystals are to be used with these fireplaces. Use of any other type of pebbles. glass crystals or other material can create a danger and will void the warranty. River Pebbles shown surrounding a Sunrise Burner Natural River Pebbles shown surrounding the a Horizon Burner Glass Crystals shown surrounding the Burner Regency Horizonm 14240E Gas Fireplace EFTA00301470 INSTALLATION GLASS DOOR INSTALLATION The glass door comes with a black frame. 1) To install the frame and glass door, simply hook the top door flange onto the top of the unit and swing the door towards the unit, Diagram 1. Note: Be careful that the glass gasket does not roll up: there must be a gap between the gasket and the door lip to ensure that the door sits securely on the unit. See Diagram 2. Hook top of door onto top flange Flush Door Flush Door Gasket Glass Correct Door/Glass/Gasket Installation. Incorrect Gasket: doubled up, filling gap. Diagram 2 2) With the door in proper position • secure with 2 screws in locations shown in Diagram 3. Diagram 3 3) Install cover plates over each screw with 2 magnets each as shown below. Magnet Cover Plate Diagram 4 Cover Plates Installed Diagram 5 Regency Horizon"' HZ40E Gas Fireplace EFTA00301471 INSTALLATION OPTIONAL MESH GLASS GUARD 1) Remove left side and right side door frame screws. 2) Using existing door frame screw, install latrer mesh mounting brackets on left side and right side. as shown. Lower mesh mown ing brackets 3) Install mesh screen. flush side facing out. 4) Install left side and right side top mountng dips approximately 3' from each side. NOTE: Clips should line up with the edge of the outer edge of the glass door flange - see glass door nstall for illustration. Mesh mounting clips 5) Install faceplate - refer to faceplate installation instructions in manual. Regency Horizon"' HZ40E Gas Fireplace EFTA00301472 INSTALLATION 4 PIECE FACEPLATE INSTALLATION 1) If installing optional mesh glass guard - See °Monet 'Mesh Glass Guard' installation instructions. 2) Instal brackets onto me back of me faceplate - 3 screws for each bracket in locations shown below. 3) To instal me 4 pc. faceplate - hook brackets (located on back of faceplate) over the two middle tabs on the glass door frame. If thicker finishing materials are used - the faceplate may be adjusted out - up to lir 1 NV? .1H' Use era notch al bracket for standard instagetton Edge of Hangs on fireplace 1 44 (38mm) Hook bracket over these tabs Important: L2' gap required between faceplate and Wished mai when using part 0256-924. 256-926.256- 927 (4 pc. faceplate). Final Instal Regency HorizonTM HZ40E Gas Fireplace EFTA00301473 INSTALLATION INNER AND OUTER DOOR FRAME INSTALLATION Note: HZ40E only - if instilling optional mesh glass guard - See optional mesh glass guard instruction in the manual. 1) Install 4 magnets onto 4 comers of glass frame prior to installing the inner door frame. 2) Install the inner door frame - lit it over the glass door frame. 3) Instal theouterdoorframeto the uni1by hooking the left and right sxle mounting brackets into the mounting slots at the sale of the firebox as shown below. It is recommended that you use the first mounting slot (the one closest to the door frame overlay) out of the 3 so that the faceplate and door frame overlay are flush with one another. NOTE: There are 3 mounting slots available. this is toaccommodate any finishing that protrudes sightly beyond the faceplate. Pin Fl Tab on Faceplate Bracket in Una CompletoO .nner occr frame and faceplate instatfabon Note: Inner door frame may be installed by itself, or with the outer door frame. The outer door frame cannot be installed by itself - if install- ing the outer door frame - the inner door frame must also be installed. 918-905a 1 08124111 Regency Horizon*" HZ40E Gas Fireplace EFTA00301474 OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS 1) Read and understand these instructionsbefore operating this appliance. 2) Check to see that all wiring is correct and enclosed to prevent possible shock. 3) Check to ensure there are no gas leaks. 4) Make sure the glass in the glass door frame is properly positioned. Never operate the appliance with the glass removed. 5) Verify that the venting and cap are unobstructed. 6) The unit should never be turned off, and on again without a minimum of a 60 second wait. FIRST FIRE The FIRST FIRE in your heater is part of the paint curing process. To ensure the paint is properly cured, it is recommended you burn your fireplace for at least four (4) hours the first time. When first operated. the unit will release an odour caused by the curing of the paint and the burning off of anyoilsremaining from manufacturing. Smoke detectors in the house may go off at this time. Open a few windows to ventilate the room for a couple of hours. The glass may require cleaning. NOTE: When the glass is cold and the appliance is lit, it may cause condensation and fog the glass. This condensation is normal and will disappear in a few minutes as the glass heats up. DO NOTATTEMPTTO CLEAN THE GLASS WHILE IT IS STILL HOT! DO NOT BURN THE UNIT WITHOUT THE GLASS DOOR IN PLACE. During the first few fires, a white film maydevelop on the glass front as part of the curing process. The glass should be cleaned after the unit has cooled down or the film will bake on and become very difficult to remove. Use a non-abrasive cleaner and DO NOT ATTEMPT TO CLEAN THE GLASS WHILE IT IS HOT. LIGHTING PROCEDURE IMPORTANT To ignite or reignite the pilot, you must first remove the glass door. 1) Press and release on ON:OFF button once on the remote control or ON/OFF switch. 2) After approximately 4 seconds the spark ignition system will spark for 60 seconds to light the main burner. 3) The unit will turn on. Note: The first try for Ignition will last approxi- mately60seoonds. If thereisnoflame ignition (rectification) the board will stop sparking for approximately 35 seconds. After wait time the board will start second try for ignition by sparking for approximately 60 seconds . If there is still no positive ignition the board will go into lock out. The system will need to be reset as follows: a) Turn the system off using ON/OFF switch or press ON/OFF button • if using optional remote. b) After approximately 2 seconds turn on ON/ OFF switch or press ON/OFF button if using optional remote. c) Repeat step 2. If the appliance will not operate, follow the instructions "To Turn Off Gas to Appliance" and call your service technician or gas supplier. SHUTDOWN PROCEDURE 1) Turn the wall mounted switch or remote to the "OFF" position. 2) Press 'OFF' on the remote control. NORMAL OPERATING SOUNDS OF GAS APPLIANCES It is possible that you will hear some sounds from your gas appliance. This is perfectly normal due to the fact that there are various gauges and types of steel used within your appliance. Listed below are some examples. All are normal operating sounds and should not be considered as defects in your appliance. Burner Tray: The burner tray is positioned directly under the burner and is made of a different gauge material from the rest of the firebox and body. Therefore, the varying thicknessesof steelwillexpandancicontract at slightly different rates which can cause 'licking' and "cracking' sounds. You should also be aware that as there are temperature changes within the unit these sounds will likely re-occur. Again, this is normal for steel fireboxes. Pilot Flame: While the pilot flame is on it can make a very slight "whisper" sound. Gas Control Valve: As the gas control valve turns ON and OFF, a dull clicking sound may be audible, this is normal operation of a gas regulator or valve. Unit Body/Firebox: Different types and thicknesses of steel will expand and contract at different rates resulting in some "cracking" and "ticking' sounds will be heard throughout the cycling process. Blower Thermodlsc: When this thermally activatedswitch turns ON it will create a small "clicking" sound. This is the switch contacts closing and is normal. Regency Horizon"' HZ40E Gas Fireplace EFTA00301475 OPERATING INSTRUCTIONS COPY OF LIGHTING PLATE INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING - TIM appllance must be installod In accoedanco MUI bral codes. II any: Il none. loges th* National Font Cas Code. »al 2223.UNFPA 54. or Nattmal Cas and Program In/ aandien Codes, CSA B141.1 WARNING: II you do not fellow these instructions exactly. a lire er explosion may fezelt tauzing preparty damage. personal Injury or loss of file. Improper instal lallen. adjustment. alterahon. service or maintenance ten cause injury or property dametje. Refer to the ownees information menuet provided with this appliance. For assistente or additional information consult a qualilied insteller. service agency or gas supplier. AVERTISSEMENT. Ouiconque ne respecte pas á la lettre les instructions dans la presente notiee risquede déclencher u ' ' uneexplosion entrainant des des blessures ega mort. Une installation. de medification.deserviceou peut provoquer des blessures ou des dommages ma erwt,. Reportez•vous au menuet u propt ire de rinformation fournie avec cel :Beparelt. Peur obtenir de raide ou des inlormations supplémentaires tonuller un installateur geologe. une agente de service ou fournisseur de gaz. A) ibis ~hamen cpapped vees art IgnOon amme ehichaldenalealy sghis iho o/ol. Dona sy b fghl dm pk) by eend. B) BEFORE OPERATING snee MI Rand !he ~erna OM fer EM. Be etre le enne oen s, ge hm, botaus* tann gis m barut [han alt end Mi soli» on eti box VMATTOOOIFVOU SNEU. CAS - Don« bylolittenyezerinee. • Do not touch Day stetest Mick da nol uso arry phono in das bulding. • Immedlay ron yo.rgassuppler kon a neighbous necne. Forma dm gas suppedys calruCba, • II ytYJ om« Mede treur gal Papptet. cal dm fee depeilmeni. C) De nol zee The apeliVraellanyMel hes been Omkenter Immedady alla ~Wel service tocImMan to Impact lep opplenen and roplaco arry pan WIM control sysum and any pas oanird %%Neb bas been underwalor. G) Cel apentelg aar diaah) bui /gumt eutematiquement le miteuee No lento pas a voticsno memo B)AVANT DE FAIRE FONCT1ONNER. renner DR aitar de lapparel pour ~dor am <cc-, dego. Rasnet erts du ortinchm. cv totoks g« Smit Diorti4dir Ra Oor el peuven: 8.erraiMuler ee niveau du sol. OUE FARE Si VOUS WOU UNE COEUR DE 43AZ: • Ne Oe lente( WE • Ile Molmt i alt m «Item/plm. ne pee MMInsi des Matptmee se Ircvmanl dans le baansent. -Appelez nwedialemeni enho toonamm do gat doom un vaan Sumaz les metageis du reuma em • S: voos ne panset mitste le legml meur. acetat le ~b°, ene anneks Cl OM pas col enorm se aØ Ocege aanstorm. MMO parhollomont, Fades irrigator I appatol par un toch. noen godtfil el real layez Mulo ~Ie di systime de conhOW el lokte commtsle eo. ent 410 plenaire &n I eau CAUTION: Hot whie in *penden. Do not touch. Severe Burns may result. Due to high surface ternperatures keep chRdren. clothing and furngure.gasoline and ether liquide hoving flammable vapors away. Keep burner and control compartment clean. See installation and operating instructions accompanying appliance. OPERATING INSTRUCTIONS STOP! Read the safety information above on Ns label. ll nam on ØF switch 2) ARM ePflrosirnatelY I timend* Uw spark ignalnal syarm vin *park fa 40 iemands le light Re main Immer, 3) Re eelt vnll turn on. Nota: The Rat anemie' Iro Ignition wel last approximatoly 60 seconde.. II teem Is no name [gallon troctillca• timp th* boardME stop onreine let approMmilety 15 maand,. After INti weitime. Ms board wIll start a ristend to lor ignition by eparkIng tor appmaimately 60 monde. IV Thee, in elIll no posidve Ignhion ener tnt second anemel th* board MUI go INC lock out. Tin system wal nood to be fesol as folkwes (alter goIng Ina lotto.« mode): a) Tom Cie spleen ofl esing ROOF, crash Vlag 5 Mnute' to daar out any gas. Tinto smelt lor ges. blote:eng nou Te nov. Il you smell gas STOMERIJ/ra stop ' In the Satety information above on this label. It you dool smolt gas. go to the nest slep. bi Turn on °ROEF match er press ØF button II sang optional ~Me, c) Unit mil repeat step 2. It lbo epigram* Mg not opmat*. kaow the instructIons me Tum On Gas to Appllance" and earl your service technician or ges supPliw STOP! Lire les consignes de sécurité cidessus sur tette Etiquette 1) Aanwet le bouten OIO OFF 2) Allerdre a seconden. te eysléme produira des 'Onmens pendant 10 secondes abn- lo Orateur penlaat. 9) les Rammen n'allumeront. ftsmarque ' Au le flanwies 60 Si Fesal premier allurnage. systeme lente jles pendant secondes est moutoryx. le system lalt un pause <l e... 'old co pion appeae telededo rectlfkathan. atal Co al OcoM. systems lento d nouveau les dommes en produlsaM des seincodes pendant% seconden. Si les Rammes ne trallunent Muleta* pan. Ie eyeAéme se mel en mede venomalege. H fer /dom le réinklelieer en suivant lee *Mee sidesaus Ipour Ie ~mondt«) : a) beIgnia le systemo en utaisant nntenupteur ON t OFF. Mende* 5 minute* peur bisser *Rapper toet le gab Puls somt« pons uno *dat do pm. y tempels pees du plancherli mus ambo une odeur de gat ARReitz, Stayer Mime lam des consigne, de sluret cldeseue em tall. étiquelle. SI MIS na tantes pas de gas. passes i ritme suivante. b) Et ralla or le sysame a raldo de l'Internapteur ou do la tatecomnando. c) L'unatá repelera retort 2. SI rappere« ne toneonna pas. sundt los Instructions "aow cours le gat a rappe/odb et appel« volro lach. Mcien mi volte knamleseur de ged. TO TURN OFF GAS APPLIANCE 1) Turn ott OreOFF svritth 2) tt service is to be pertomwd • you MUM clisconnect power to tact unit hom tb, baeery pack. retor to manual. 1) Ap1/11yOZ slit le bouten ON 1 OFF 2) SI Ie bonk* est offottuée. voos dam clabrancter rapperell. W Moed:dos. vok lo manual POLI' plus de Mails. DO NOT REMOVE THIS INSTRUCTION PLATE Mt.426. Regency Horizon"' HZ40E Gas Fireplate EFTA00301476 MAINTENANCE MAINTENANCE INSTRUCTIONS 1) Always turn off the gas and electrical supply before cleaning. For relighting. refer to lighting instructions. Keep the burner and control compartmentcleanbybrushingandvacuuming at least once a year. 2) Clean appliance and door with a damp cloth (never when unit is hot). Never use an abrasive cleaner. The glass shou Id be cleaned with a gas fireplace glass cleaner. The glass should be cleaned when it starts looking cloudy. 3) The faceplate is finished in a heat resistant paint and should only be refinished with heat resistant paint. Regency' uses StoveBright Paint Metallic Black #6309. Note: Faceplates and Inner panels made from stalnlesssteelwillnaturallychangecolor over time. 4) Make a periodic check of burner for proper position and condition. Visually check the flame of theburner periodically. making suretheflames are steady: not lifting of floating. If there is a problem. call a qualified service person. 5) The appliance and venting system must be inspected before use. and at least annually, by a qualified field service person. to ensure that the flow of combustion and ventilation air is not obstructed. Note: Never operate the appliance without the glass properly secured in place. 6) Do not use this appliance if any part has been underwater. Immediately call a qual if ied service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water. 7) In the event this appliance has been serviced checkthatthevent-airsystem hasbeen properly resealed & reinstalled in accordance with the manufacturers instructions. 8) Verily operation after servicing. GLASS GASKET If the glass gasket requires replacement use a tadpole glass gasket (Part # 936-159). GLASS DOOR Your Regency° fireplace is supplied with high temperature 5mm-Ceramic glass. If your glass requires cleaning, we recommend using an approved glass cleaner available at all authorized dealers. Do not use abrasive materials. CAUTION & WARNINGS: ' Do not clean when the glass is hot. ' The use of substitute glass will void all product warranties. • Care must be taken to avoid breakage of the glass. • Do not strike or abuse the glass. • Do not operate this fireplace without the glass front or with a cracked or broken glass front. • Weargloves when removing damaged orbtoken glass. • Replacement of the glass panel(s) should be done by a licensed or qualified service per son. GLASS REPLACEMENT In the event that you break your glass by impact. purchase your replacement from an authorized Regency' dealer only. Replacement neocetamic glass (Part # 9403611P) is shipped with gasket. CAUTION: Weargloves when removing damaged or broken glass. WARNING: Do not operate the appliance with the glass panels removed, cracked or broken. Replacement of the glass panels should be done by a licensed or qualified service person. GENERAL VENT MAINTENANCE Conduct an inspection of the venting system semi- annually. Recommended areasto inspect asfollows: 1) C heck the Venting System for corrosion in areas that are exposed to the elements. These will appear as rust spots or streaks. and in extreme cases. holes. These components should be replaced immediately. 2) RemovetheCap. and shinea flashlight down the Vent. Remove any bird nests. or other foreign material. 3) Cheddorevidencesofexcessivecondensation. such as water droplets forming in the inner liner, and subsequently dripping out the joints. Continuous condensation can cause corrosion of caps. pipe. and fittings. It may be caused by having excessive lateral runs. too many elbows, and exterior portions of the system being exposed to cold weather. 4) Inspect joints. to verity that no pipe sections or fittings have been disturbed, and consequently loosened.Alsocheck mechanical supports such as Wall Straps. or plumbers' tape for rigidity. Regency Horizon"' HZ40E Gas Fireplace EFTA00301477 MAINTENANCE VALVE ASSEMBLY REPLACEMENT 1) Turn the unit off and allow it to cool down to room temperature. 2) Shut off the gas and power supply to the unit. 3) Remove the faceplate or door frame -see instruction in this manual. 4) Remove the glass door. a) Remove the 3 screws shown below at the bottom of the glass door. b) Swing the door out 45° from the bottom and lift up and out. 5) Remove the inner panels - reverse of 'Inner panel Installation' in this manual. 6) Remove the burner tray cover by lifting up and out as shown below. ' Prior to removing burner - remove crystals. pebbles, spa stones and inner panels if installed. 7) Remove 3 screws on the bumer to release it - locations shown below. 8) Remove the burner by sliding it to the right then lift out. 1 9) Remove the valve access plate by undoing the 8 screws - see locations below. 10) Disconnect the inlet gas line and remove the valve Illata.;;;;; NaiL r 11) Replace valve assembly and reverse steps. Regency Horizon*" HZ40E Gas Fireplace EFTA00301478 PARTS LIST MAIN ASSEMBLY Part If Description Part a Description 1 256-038 Frame Door HZ40E 6 911-024 Valve NG 880 SIT IPI 2 940-361/P Glass Neoceram Flush HZ40E 911-025 Valve LP 880 SIT IPI 3 256-039 Bottom Tray HZ40E 7 911-006 Pilot Assembly IPI NG 4 256-525 Burner Assembly NG c/w Cap HZ40E 911-007 Pilot Assembly IPI LP 256-530 Burner Assembly LP c/w Cap HZ40E 8 256-574E/P Valve Assembly HZ40E NG SIT 5 904-345 Orifice #53 LP 256-576E/P Valve Assembly HZ40E LP SIT 904-593 Orifice a40 NG 9 910-157/P Fan Low Speed (Dual Blower) 911-012 Ignition board 911-013 IPI/CPI Switch Not Shown 60 Regency Horizon TM HZ40E Gas Fireplace EFTA00301479 PARTS LIST ACCESSORIES Pait # 10) 316-907 316-908 11) 256-924 256-926 256-927 256-934 256-936 256-947 256-944 256-946 256-947 946-676 946-672 946-673 946-674 Description Reflective Stainless Steel Inner Panels Black Enamel Inner Panels Faceplate Black Faceplate Sunset Bronze Faceplate Brushed Stainless Outer Door Frame Black Outer Door Frame Bold Outer Door Frame Stainless Inner Door Frame Black Inner Door Frame Bold Inner Door Frame Stainless Copper Glass Crystals Natural River Pebbles White River Pebbles Ceramic Spa Stones 11 Regency Horizon"' HZ40E Gas Fireplace EFTA00301480 NOTES Regency Horizon"' HZ40E Gas Fireplace EFTA00301481 WARRANTY OR FIREPLACE PRODUCTS (' Regency' Fireplace Products are designed with reliability and simplicity In mind. In addition. our Internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our facility. Regency* Fireplace Products is pleased to extend this limits lifetime warranty to the ordained purchaser of a Regency' Product. This warranty is not transferable. The Warranty: Limited Lifetime The combustion chanter. heat exchanger. burner tubesiVans. logs. glass crystals. ceramic spa stones, potties. ea* panels and gold pasting (against defective manufacture only) are covered under the Limed Warne Warranty for five (5) years for parts and subsidized labour' and pads only thereafter. Glass is covered for lifetime against thermal breakage only. pans and subsidized labour' for live (5) years and pans only thereafter from date 01 purchase. External casting, surrounds and grills are covered against cracks and warps resultng from manufacturer defects. pans and subsidized labour for three (3) years from the date of purchase and pads only thereafter. Special Finishes One year on stainless steel panes. nickel overlays.nickel taceplates. Crushed nickel and antique copper full screens and doors. You can expect some changes ri color as the product 'ages' with constant heating and cooling. Regency warranties the product for any manufacturing defects on the original product. However. the manufacturers warranty does not cover changing colors and marks. ie. finger prints. etc applied after the purchase of the product. Damage from the use of abrasive cleaners is not covered by warranty. Electrical and mechanics components such as blowers. switches. wiring, themiodiscs. Regency° remote controls. spa switches. themvpiles. thermocouples. plot assembly components. and gas valves are covered for Iwo years pans and one year subsidized labour' from the date of purchase. Blowers and valves replaced under warranty are considered repairs and continue as if new with appbance. ie. lweNe 112) months from original purchase date ci appliance with a minimum 01 three (3) months coverage from date of replacement. Regency venting components are covered pans and subsidized labour' for three (3) years from date of purchase. Simpson Dura-Vent venting conponents (Direct Vent units) are covered by Simpson Dura-Vent Inc. warranty. Repair/replacement pans purchased by the consumer from Regencye after the original coverage has expired on the unit will carry a 90 day warranty. valid with a receipt only. Any nem shorn to be defective will be repaired or replaced at our discretion. No labor coverage is included vnth these pans. Conditions: Any pan or pads of this unit which in our judgement show evidence of such defects will be repaired or replaced at Regency's option. through an accredited distnbutor or agent provided that the defective pan be relumed to the distnbutor or agent Transportation Prepaid if requested. Porcelain£namel - Absolute perfection is either guaranteed nor commercially possible. My chips must be reported and inspected by an authorized dealer within three days of instalation. Reported damage after this time will be subject to rejection It is the general practice of Regency. to charge for larger, higher priced replacement pans and issue credit once the replaced component has been returned to Regency and evaluated for manutaclurer defect. The authorized selling dealer is responsible for all n -field service work earned out on your Regencr product. Regency will not be liable for results or costs of workmanship from unauthorized service persons or dealers. At as times Regency reserves the right to inspect product in the field which is claimed to be defective. Al claims must be submitted to Regencye by authorized selling dealers. It is essential that as submitted class provide all 01 the necessary information including customer name. purchase date. serial N. type of unit, problem. and pad or parts requested. without this information the warranty will be invald. Exclusions: This limited Lifetime Warranty does not extend to or include paint. door or glass gaskebng or Inn. At no time via Regency° be liable for any consequential damages which exceed the purchase prize 01 the unit. Regency'shas no orolgation to enhance or modify any unit once manufactured. ie. as products evolve. field modifications or upgrades will not be performed. Regency° will not be liable for travel costs for service work. Installation and environmental problems are not the responsibility of the manufacturer and therefore are not covered under the terms of this warranty policy. Embers. rockwool. gaskets, door !uncles and pawn are not covered under the terms of this warranty policy. Any unit which shows signs of neglect or misuse Is not covered under the terms of this warranty policy. The warranty via not extend to any pad which has been tampered with or altered in any way, or in our judgment has been subject to misuse. improper instalation. negbgence or accdent spillage or downdrafts caused by enwonnental or geographical conditions. inadequate venblation. excessive onsets. negative art pressure caused by mechanical systems such as lumaces. fans. clothes dryer. etc. Freight damage to stoves and replacement pads is not covered by warranty and is subsol to a claim against the freight carrier by the dealer. Regency will not be liable for acts 01 God, or acts 01 terrorism. which cause mallunclion 01 the appliance. Performance problems due to operator error will not be covered by this warranty policy. Products made or provided by other manufacturers and used in conjunction with the operation of this appliance without prior authorization from Regency.. may nobly your warranty on this product. My alteration to the lint which causes sooting or carbonng that resins in damage to the interior / exterior facia is not the responsibility of Regency°. • Subskly according to job scale as predeterrnmed by FPI. Regency HorizonTM HZ40E Gas Fireplace EFTA00301482 Register your Regency° warranty online www.regency-fi Reasons to register your product online today! • View and modify a list of all your registered products. • Request automatic email notification of new product updates. • Stay informed about the current promotions, events, and special offers on related products. Installer: Please complete the following information Dealer Name & Address: Installer: Phone #: Date Installed: Serial No.: Regency Honzon and SureFire are trademarks of FPI Fireplace Products International Ltd. © Copyright 2012 FPI Fireplace Products International Ltd. All rights resented. Printed in Canada EFTA00301483

Document Preview

PDF source document
This document was extracted from a PDF. No image preview is available. The OCR text is shown on the left.

Extracted Information

Dates

Document Details

Filename EFTA00301420.pdf
File Size 5379.2 KB
OCR Confidence 85.0%
Has Readable Text Yes
Text Length 128,614 characters
Indexed 2026-02-11T13:24:45.028868
Ask the Files