EFTA00301420.pdf
PDF Source (No Download)
Extracted Text (OCR)
OREGENCY
Regency HorizonTM HZ4OE
Gas Fireplace
WARNING:
If the information in these instructions are not followed exactly,
a fire or explosion may result causing property damage,
personal injury or loss of life.
FOR YOUR SAFETY
Do not store or use gasoline or other flammable vapors and
liquids in the vicinity of this or any other appliance.
Installation and service must be performed by a qualified
installer, service agency or the gas supplier.
It,ted by.
EDI
Intertek
Owners &
Installation Manual
MODELS:
14Z40E•NG1 Natural Gas
I4Z40E•LP1 Propane
FOR YOUR SAFETY
What to do if you smell gas:
• Do not try to light any appliance
• Do not touch any electrical switch:
do not use any phone in your
building.
• Immediately call your gas supplier
from a neighbour's phone. Follow
the gas supplier's instructions.
• If you cannot reach your gas
supplier, call the fire department.
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
919 165
FM FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1144
05/29/12
EFTA00301420
MANUFACTURED MOBILE HOME REQUIREMENTS
INFORMATION FOR MOBILE/MANUFACTURED HOMES AFTER FIRST SALE
This Regencr product has been tested and listed by Warnock Hersey/Intertek as a Direct Vent Wall Furnace to the following
standards: VENTED GAS FIREPLACE HEATERS ANSI Z21.88-2009/ CSA 2.33-2009 and GAS-FIRED APPLIANCES FOR
USE AT HIGH ALTITUDES CAN / CGA 2.17-M91.
This appliance may only be installed in an aftermarket permanently located, manufactured (U.S.A only) or mobile home,
where not prohibited by local codes.
This Direct Vent System Appliance must be installed in accordance with the manufacturers installation instructions and the
Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, or the current Standard of Fire Safety Criteria
for Manufactured Home Installations, Sites, and Communities ANSI/NFPA 501A, and with CAN/CSA Z240-MH Mobile Home
Standard in Canada.
This appliance installation must comply with the manufacturers installation instructions and local codes, it any. In the absence
of local codes follow the current National Fuel Gas Code, ANSI 2223.1 and the current National Electrical Code ANSI/NFPA
70 in the U.S.A., and the current CAN/CGA B149 Gas Installation Code and the current Canadian Electrical Code CSA C22.1
in Canada.
This appliance comes equipped with a dedicated #8 Ground Lug for attachment of the ground wire to the steel chassis as
applicable to local codes.
The appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the
National Electrical Code, ANSI/NFPA 70. or the Canadian Electrical Code, CSA C22.1.
This appliance can only be used with the type of gas indicated on the rating plate.
This appliance is not convertible for use with other gases.
Ensure that structural members are not cut or weakened during installation.
This appliance may be installed as an OEM installation in a manufactured home (USA only) or mobile home and must be
installed in accordance with the manufacturer's instruction and the Manufactured Home Construction and Safety Standard,
Title 24 CFR. Part 3280, in the Untied States, or the Standard for Installation in Mobile Homes, CAN/CSA Z240 Mkt, in
Canada.
WilkA
WARNING! lir
HOT GLASS WILL
CAUSE BURNS
DO NOT TOUCH GLASS
UNTIL COOLED
NEVER ALLOW CHILDREN
TO TOUCH GLASS
Regency HorlzonTM HZ40E Gas Fireplace
EFTA00301421
To the New Owner:
Congratulations!
You are the owner of a state-of-the-art Gas Fireplace by REGENCY°. The HZ40E has been
designed to provide you with all the warmth and charm of a fireplace at the flick of a switch.
The model HZ4OE has been approved by Warnock Hersey/Intertek for both safety and efficiency.
As it also bears our own mark, it promises to provide you with economy, comfort and security for
many trouble free years to follow. Please take a moment now to acquaint yourself with these
instructions and the many features of your Regency Fireplace.
marmoithu. We recommend that our products be
FIREPLACE
IRSTRLITC installed and serviced by professionals
who are certified in the U.S. by the
National Fireplace Institute° (NFI)
or in Canada by Wood
Energy Technical
Wood Emmy
Wake leateleg
NFI
CERTIFIED., Training (WETT).
ONE REGENCY
ONE TREE
TM
Regency HorlzonTM HZ40E Gas Fireplace
EFTA00301422
TABLE OF CONTENTS
SAFETY DECAL
Copy of Safety Decal
REQUIREMENTS
5
4" x 6-5/8" venting
High Elevation Gas Line Installation
Pilot Adjustment
Gas Pipe Pressure Testing
880 S.I.T. Valve Description
Aeration Adjustment
35
36
36
36
36
36
AC power adaptor installation (for surefire systems) 37
MA Code - CO Detector
6
Wiring Diagram
38
(for the State of Massachusetts only)
6
proflame system GT
38
proflame system GTM
38
INSTALLATION
proflame system GTMF with optional fan
39
optional fan Wiring Diagram
40
Important Message
Before You Start
General Safety Information
Installation Checklist
8
8
8
9
Without ProFlame GTMF system
Optional Remote Control
Receiver Wall Switch
wall mount On / Off Switch and battery compartment
installation and/or receiver installation
40
41
41
42
Locating Your Gas Fireplace
Heatwave Duct System
Heat Release kit
Clearances
Mantel Clearances
Mantel Leg Clearances
Unit Assembly Prior To Installation
Nailing Strips
Installation Access panel
Front face Nailing strip installation
Framing Dimensions
9
9
9
10
11
11
12
12
12
12
13
GTMF remote installation
Optional fan Installation
Optional fan Installation - into existing installations
Inner Panel Installation
Glass Crystals or optional ceramic stones
Optional Pebble / Crystal Installation
Glass door Installation
Optional mesh glass guard
4 piece faceplate installation
Inner and outer door frame installation
43
46
47
49
50
51
52
53
54
55
Non-Combustible Requirements
Non-combustible facing installation
Framing & Finishing
14
14
15
OPERATING INSTRUCTIONS
Framing & Finishing
16
Operating Instructions
56
Non-Combustible Requirements
16
First Fire
56
Exterior Vent Termination Requirements
17
Lighting Procedure
56
4" x 6-5/8" Rigid Pipe
18
Shutdown Procedure
56
Cross Reference Chart only
18
Normal Operating Sounds of Gas Appliances
56
Vent Restrictor Position
20
Copy of Lighting Plate Instructions
57
Venting Introduction
21
Maintenance Instructions
58
Venting Arrangement for Horizontal Terminations
21
Glass Gasket
58
Horizontal Terminations
22
Glass Door
58
Flex Vent 4" x 6-7/8"
22
Glass Replacement
58
Horizontal terminations
23
General Vent Maintenance
58
Rigid Pipe 4" x 6-5/8"
23
Valve assembly Replacement
59
Horizontal Terminations
Rigid Pipe 4" x 6-5/8"
Vertical terminations
Rigid Pipe 4" x 6-5/8"
24
24
27
27
PARTS LIST
Venting Arrangement for Vertical Terminations
28
Main Assembly
60
Vertical Termination with Co-Linear Flex System
29
Accessories
61
Vertical Terminations
Rigid Pipe 4" x 6-5/8"
Venting Arrangements - Vertical Terminations
Unit Installation with Horizontal Termination
30
30
32
33
WARRANTY
4" x 6-5/8" venting
33
The Warranty: Limited Lifetime
63
Unit Installation with Horizontal Termination
Unit installation with Vertical Termination
34
35
Regency Horizon"' HZ40E Gas Fireplace
EFTA00301423
SAFETY LABEL
This is a copy of the label that accompanies
each HZ40E-NG1 and HZ40E-LP1 Direct Vent
Gas Fireplace. We have printed a copy of the
contents here for your review.
NOTE: Regency, units are constantly being
improved. Check the label on the unit and if
there is a difference, the label on the unit is the
correct one.
COPY OF SAFETY DECAL
Intertek
4001172
O
NATURAL GAS: Model H240E-NG1
Minimum supply pressure
Manifold pressure
Orifice sue
Maximum input
Minimum input
Altitude
Lined: VENTED GAS FIREPLACE HEATER! FOYER AU GAZ A EVACUATION DO NOT REMOVE THIS LABEL r NE PAS ENLEVER CETTE ETIQUETTE
Certified for/Leith& pour: CANADA and U.S A.
Tested to: CAN/CGA-2.17-M91(R2009)
ANSI 221.88-2009/CSA 2.33-2009
MAY BE INSTALLED IN MANUFACTURED (MOBILE' HOMES AFTER FIRST SALE.
litREPN.cT
Serial No/ No de aerie
412
5if
WC/C.E. (125IPa)
34
WCIC.E. f327IPa)
IMO
CA1S
26.000 Mufti (7.61 kW)
18,000 Mufti (5 28 kW)
04500
Dpi
(0-1372m)
O
PROPANE GAS: Model HZ40E-LPI
Mnimum supply pressure
Manifold pressure
Orifice sae
MaxmLon Input
Minimum Input
Altitude
11' WC
(2.73 kpa)
10'
WC1C.E. (2491Pa)
#53
CMS
25.500 Btuiti
(7.47kW)
21.000 Bbih (6.15 kW)
04500
fipl
(0-1372m)
APPAREIL FONCTIONNANT AU NATURAL GAS
CONCU POUR ETRE POELE: Mode* HZ40E-NG1
Preston
mnimurn
Preston a la aibulum dechappement Neves
Grandeur de nnecteur
Debt Calonligue maximum salon
Yaltitude
EQUIPE A CUISINE POUR GAZ PROPANE
CONCU POUR ETRE POELE: ModeleHT.40E-LP1
Preston
Minimum
Presslon a b turauNre dolchapperneM elevee
Grandeur de I1Mecteur
DeWI Calorilque maxenum scion
raktude
Minimum Clearances to Combustibles I
Degagement Minimum De Materisux Combustibles
DOOR SEAL: Please
check that the door is
properly sealed
Side Walls
A
Er (203mm)
Ceiling
8
22' (559mm)
Min. Mantel Height
C
1r (432mm)
Max. Mantel Depth
13" (330mm)
Alcove Width
E
84" (1524mm)
Alcove Depth
F
36- (2134mm)
lawsuitsction Munui let
minute:ens)
This appliance must be inslallad n aconlance *Mb local codes. if any: if nom. Sow the National Fool Gas Code. ANSI 2223.1. cr Natural Gas and Propane Install on Code. GSA0169.1.
This MpliaMe muslin :Walled ine000rdance wen me StandiedCAN:CSAZ2401M. M0bleHousino.in Canada. Or wsb me HanulachgedHolneCcoseucbonandSalgYSlandard. tee 24 CFRP(0 3280.in
the Veiled SOWS. C. wails, SW) StaMarO PS Mt apoicams.ANSUKSBCS A225 liNFPASOI A. Mantoactured Horne IntlellatiCOS Standard C•ANSI All 9.20u NFPA SOIC standard reeRecreed4no Wades
This appliamo is only forum ailh the type dips irdicalcd rolls recap plate and may be mimed n an aftermarkel. permanently lomat manufactuogrnobilaThomewhere nc4pohlaited bylocal cedes. See
vanes manual fordetals. This applance d notoomembie torus, enhothareases.wiless a certifed iutisused.
Installer reooenFlselonles codes ourealementsOcata. ou.en rabeence de MK Nolemerts. INICOIOS 01:la
2223.1. National FuelGasCode ouCSA43149.1 en vIgueur
Installer repoereil salon le norms CAN'CSA-Z240. Sane WM. MilltiOn MOON, Ou CANCSA-Z240 VC. VOIColOS 00 CaMOIn0. Ou la tonne 24 CFR Pert 3280. ManulaCtunid HOMO Consau(ton and Safety
Standard. Si ces norm*, ne pampas acclimates. utilsez le normeANSUNCSBCSA225.1/NFPA 501A. Manufactured Home Installations Standard. ouANSI AI 19 2 ou NFPASOIC Standardfor Recreational
Vehicles.
Cal apparel don etre dela. unouemem avec to tyDedepa2 ndiove suns plaque signeXHIgue.Cecamaret.o errs ru"s"e O&M. unBmiton preeabnqueeou moDhe le -V. SeuleclaliV)InSIfille daMtoule Si
les retflaMenISIOG3us le DaMeltenl Writ WOG Cla IVIIMSSor pets pluSde fenSeirecnertS CSISCOOMII= [OS COnAutible DOurunS ulllexIbOnaveCilliti$2.aSurS. on. If CuSSOCONDS *SI Vella
Thls vented gas fireplace heater is not forme wither Altars.
Ne pas utikserde Niro a air avec ce foyerau pas itevacuatIon.
FORUSEWITHGLASSDOORSCERTIFIEDWITH THEAPPLIANCEONLY
POUR UMISATIONUMOUEMENT AVEC LESPORTESENVERRECERTIFIEESAVEC L'APPAREIL
Fan (1Pala 258-911)
vase," canals. Fdroon au Canals
Ela-tical supply l Electrique 115VAC. 1.13A 6011t
NOT FOR USE WITH SOLID FUELS.! NE PAS UTILISER AVEC DU COMEIUSTBLE SOLIDE.
FPI Fireplace Products International Ltd. Delta. BC. Canada
9i#166
For the State of Massachusetts, installation
and repair must be done by a plumber or
gasfitter licensed in the Commonwealth of
Massachusetts.
For theStateof Massachusetts. flexible con-
nectors shall not exceed 36 inches in length.
For the State of Massachusetts, the appli-
ances individual manual shut-off must be a
t-handle type valve.
The State of Massachusetts requires the
installation of a carbon monoxide alarm in
accordance with NFPA 720 and a CO alarm
with battery back up in the same room where
the gas appliance is installed.
Regency HorizonTM HZ40E Gas Fireplace
EFTA00301424
REQUIREMENTS
MA Code - CO Detector
(for the State of Massachusetts only)
5.08: flodlfleatIons to NFPA-54. Chapter 10
(2) Revise 10.8.3 by adding the following additional requirements:
(a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in pan for
residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than
seven (7) feet above finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall
be satisfied:
1. INSTALLATION OF CARBON MONOXIDE DETECTORS. At the time of installation of the side wall horizontal vented gas fueled
equipment, the installing plumber or guiltier shall observe that a hard wired carbon monoxide detector with an alarm and battery back-up is
installed on the floor level where the gas equipment is to be installed. In addition, the installing plumber or gasfitter shall observe that a battery
operated or hard wired carbon monoxide detector with an alarm is installed on each additional level of the dwelling, building or structure
served by the side wall horizontal vented gas fueled equipment. It shall be the responsibility of the property owner to secure the services of
qualified licensed professionals for the installation of hard wired carbon monoxide detectors
a. In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic. the hard wired carbon
monoxide detector with alarm and battery back-up may be installed on the next adjacent floor level.
b. In the event that the requirements of this subdivision can not be met at the time of completion of installation, the owner shall have a period of
thirty (30) days to comply with the above requirements: provided, however. that during said thirty (30) day period. a battery operated carbon
monoxide detector with an alarm shall be installed.
2. APPROVED CARBON MONOXIDE DETECTORS. Each carbon monoxide detector as required in accordance with the above provisions
shall comply with NFPA 720 and be ANSUUL 2034 listed and IAS certified.
3. SIGNAGE A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum height of eight
(8) feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled healing appliance or. equipment. The
sign shall read in print size no less than one-half(1f2) inch in size. "GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL
OBSTRUCTIONS".
4. INSPECTION. The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation
unless, upon inspection, the inspector observes carbon monoxide detectors and signagc installed in accordance with the provisions of 248 CMR
5.08(2X2)1 through 4.
(b) EXEMPTIONS: The following equipment is exempt from 248 CMR 5.08(2)(8)1 through 4:
1. The equipment listed in Chapter 10 entitled "Equipment Not Required To Be Vented" in the most current edition of NFPA 54 as adopted by
the Board: and
2. Product Approved side wall horizontally vented gas fueled equipment installed in a room or structure separate from the dwelling, building or
structure used in whole or in part for residential purposes.
(c) MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM PROVIDED. When the manufacturer of Product
Approved side wall horizontally vented gas equipment provides a venting system design or venting system components with the equipment. the
instructions provided by the manufacturer for installation of the equipment and the venting system shall include:
1. Detailed instructions for the installation of the venting system design or the venting system components: and
2. A complete parts list for the venting system design or venting system.
(d) MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM NOT PROVIDED. When the manufacturer of a
Product Approved side wall horizontally vented gas fueled equipment does not provide the parts for venting the flue gases. but identifies
"special venting systems", the following requirements shall be satisfied by the manufacturer:
1. The referenced "special venting system" instructions shall be included with the appliance or equipment installation alit:Will:MS: and
2. The "special venting systems" shall be Product Approved by the Board. and the instructions for that system shall include a pans list and
detailed installation instructions.
(c) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment. all seating instructions.
all pans lists for venting instructions. and'or all venting design instructions shall remain with the appliance or equipment at the completion of
the installation.
Regency Horizon"' HZ40E Gas Fireplace
EFTA00301425
DIMENSIONS
45 5/8"
PEW
39-13/16'
1
—
.
—Iv
:2
1.
—
364- —
a ,
—
43X1 (1092mm
341,4- (972mm)
(902m1
mew
El
48. (1238mrn)
4
36" (gum.)
Regency I-Icemen' 14240E Gas Fireplace
EFTA00301426
INSTALLATION
IMPORTANT MESSAGE
SAVE THESE
INSTRUCTIONS
The Gas Fireplace must be installed in accordance
with these instructions. Carefully read all the
instructions in thismanual first. Consult the'authority
having jurisdiction"todeterminetheneed for aperrnit
prior tostarting theinstallation. It is the responsibility
of the installer to ensure this fireplace is installed
in compliance with manufacturers instructions and
all applicable codes.
BEFORE YOU START
Safe installation and operation of this appliance
requires common sense, however, we are required
by the Canadian Safety Standards and ANSI
Standards to make you aware of the following:
INSTALLATION AND REPAIR SHOULD
BE DONE BY AN AUTHORIZED
SERVICE PERSON. THE APPLIANCE
SHOULD BE INSPECTED BEFORE
USE AND AT LEAST ANNUALLY BY A
PROFESSIONAL SERVICE PERSON.
MORE FREQUENT CLEANING MAY
BE REQUIRED DUE TO EXCESSIVE
LINT FROM CARPETING. BEDDING
MATERIAL,ETC.IT IS IMPERATIVETHAT
CONTROL COMPARTMENTS.BURNERS
AND CIRCULATING AIR PASSAGEWAYS
OF THE APPLIANCE BE KEPT CLEAN.
DUE TO HIGH TEMPERATURES, THE
APPLIANCE SHOULD BE LOCATED
OUT OF TRAFFIC AND AWAY FROM
FURNITURE AND DRAPERIES.
WARNING: FAILURE TO INSTALL THIS
APPLIANCE CORRECTLY WILL VOID
YOUR WARRANTY AND MAY CAUSE A
SERIOUS HOUSE FIRE.
CHILDREN AND ADULTS SHOULD BE
ALERTED TO THE HAZARDS OF HIGH
SURFACE TEMPERATURES. ESPE-
CIALLY THE FIREPLACE GLASS. AND
SHOULD STAY AWAY TO AVOID BURNS
OR CLOTHING IGNITION.
YOUNG CHILDREN SHOULD BE CARE-
FULLY SUPERVISED WHEN THEY ARE
IN THE SAME AREA AS THE APPLI-
ANCE. TODDLERS.YOUNG CHILDREN
AND OTHERS MAY BE SUSCEPTIBLE
TO ACCIDENTAL CONTACT BURNS. A
PHYSICAL BARRIERS IS RECOMMEND-
ED IF THERE ARE AT RISK INDIVIDUAL
IN THE HOUSE. TO RESTRICT ACCESS
TO A FIREPLACE OR STOVE. INSTALL
AN ADJUSTABLE SAFETY GATE TO
KEEP TODDLERS, YOUNG CHILDREN
AND OTHER AT RISK INDIVIDUALS OUT
OF THE ROOM AND AWAY FROM HOT
SURFACES.
CLOTHING OR OTHER FLAMMABLE
MATERIAL SHOULD NOT BE PLACED
ON OR NEAR THE APPLIANCE.
GENERAL SAFETY
INFORMATION
1) The appliance installation must conform with
local codesor, in theabsenceof localcodes, with
the current Canadian or National Gas Codes.
CANI -B149orANSI Z223.1 Installation Codes.
2) The appliance when installed, must be
electrically grounded in accordance with local
codes, or in the absence of local codes with the
current National Electrical Code. ANSI/NFPA 70
or CSA C22.1 Canadian Electrical Code.
3) See general construction and assembly
instructions. The appliance and vent should be
enclosed.
4) This appliance must be connected to the
specified vent and terminationcaptotheoutside
of the building envelope. Never vent to another
room or inside a building. Make sure that the
vent is fitted as per Venting instructions.
5) Inspecttheventingsystem annually forblockage
and any signs of deterioration.
6) Venting terminals shall not be recessed into a
wall or siding.
7) Any safety glass removed for servicing must be
replaced prior to operating the appliance.
8) To prevent injury, do not allow anyone who is
unfamiliarwiththeoperation to usethefireplace.
9) Wear gloves and safety glasses for protection
while doing required maintenance.
10) Be aware of electrical wiring locations in walls
and ceilings when cutting holes for termination.
11)Under no circumstance should this
appliance be modified. Parts that have
to be removed for servicing should be
replaced prior to operating this appliance.
12) Installation and any repairs to this appliance
should be done by a qualified service person.
A professional service person should be called
to inspect this appliance annually. Make it a
practice to have all of your gas appliances
checked annually.
13) Do not slam shut or strike the glass door.
14) Under no circumstances should any solid fuels
(wood. paper, cardboard, coal. etc.) be used in
this appliance.
15) The appliance area must be kept clear and free
of combustible materials. (gases andotherflam•
made vapours and liquids).
Emissions from burning wood or gas could
contain chemicals known to the State of
Califomia to cause cancer, birth defects or
other reproductive harm.
Regency Horizon"' HZ40E Gas Fireplace
EFTA00301427
INSTALLATION
INSTALLATION
CHECKLIST
1) Locate appliance
a) Room location (Refer to' ocating Your Gas
fireplace section)
b) Clearances to Combustibles (Refer to
'Clearances" section)
c) Mantle Clearances (Refer
to "Mantel
Clearances' section)
d) Framing 8 Finishing Requirements (Refer
to "Framing 8 Finishing" section)
e) Venting Requirements (Refer to "Venting'
section)
2) Position nailing strips (Refer to 'Unit Assembly
Prior to Installation).
3) Slide unit into place.
4) Remove installation access panel.
5) Install vent (Refer to 'Venting Arrangement'
sections).
6) Make gas connections (Refer to "Gas Line
Installation section).
7) Make electrical connections to receptacle
supplied with unit (recommended).
8) Install 4 AA batteries into receiver/switch box
or use optional AC power adaptor.
9)Testthe pilot (Refer to 'PilotAdjustmenrsection).
10) TestGas Pressure (Referto"Gas Pipe Pressure
Testing" section).
11) Install standard and optional features. Refer to
the following sections:
a)
b)
c)
d)
e)
f)
Glass Crystals/ Optional Ceramic
Stones
Optional Firebox Base Pebbles
Optional Reflective Panels
Optional Fan
Faceplate
Remote Control or Wall Thermostat
and 10ft. wire harness.
12) Reinstall installation access panel.
13) Final check.
Before leaving this unit with the customer, the
installer must ensure that the appliance is firing
correctly and operation fully explained to
customer.
This includes:
1) Clocking the appliance to ensure the correct
firing rate (rate noted on label 26.000 Equal
(NG).25.500 Btum (LP)after burning appliance
for 15 minutes.
2) If required. adjusting the primary air to ensure
that the flame does not carbon. First allow the
unit to bum for 15.20 min. to stabilize.
CAUTION: Any alteration to the product that
causes sooting orcarbonIng that results In dam-
age Is not the responsibility of the manufacturer.
LOCATING YOUR
GAS FIREPLACE
1) When selecting a location for your fireplace.
ensure that the clearances are met.
2) The appliance must be installed on a flat. solid.
continuous surf ace For example a wood. metal
or concrete floor or in a raised (on the wall) ap-
plication. The appliance must be installed on
a metal or wood panel extending the full width
and depth of the appliance.
3) The HZ40E Direct Vent Gas Fireplace can be
installed in a recessed position or framed out
into the room as in A. B. C and D.
See Diagram 1.
Diagram
A)
B)
C)
D)
TET
A
Flat on Wall
Flat on Wall Comer
Recessed into Wall/Alcove
Comer
4) This appliance is Listed for bedroom
installations using the standard Remote
(thermostat system). Some areas may have
funher requirements. check local codes before
installation.
5) The HZ40E Direct Vent Gas Fireplace
is approved for alcove installations, see
"Clearances" section for details.
6) We recommend that you plan your installation
on paper using exact measurements for
clearances and floor protection before actually
installing this appliance. Have an authorized
inspector. dealer. orinstaller reviewyour plans
before installation.
Note: For vent terminations refer to "Exterior
Vent Termination Locations" section.
Heat Wave
asvarr---er
HEATWAVE
DUCT SYSTEM
OPTIONAL KIT #946-556
The HeatWave Air Duct Kit increases the
effectiveness of your fireplace by dispersing warm
air from the ireplace to remote locations in the same
room or other rooms in your home.
Up to two kits may be installed on the fireplace.
Please Note: Only 1 HeatWave kit may be oper-
ated at one lime. This includes the internal blower
option as well.
alltur>"•=1.0
,"
Heat Wave
The HeatWave Duct Kit has different
clearance andframingrequirements.cbeck
the HeatWave manual for details.
OPTIONAL
HEAT RELEASE KIT
#946-570
The Heat Release Kit expels warm air from the
fireplace to the outside of the building. allowing
the fireplace to be operated with less heat entering
the room. The kit may be used on either the left
or right side.
Regency Horizon"' HZ40E Gas Fireplace
EFTA00301428
INSTALLATION
CLEARANCES
The clearances listed below are Minimum distances unless otherwise stated:
A major cause of chimney related fires Is failure to maintain required clearances (air space)to combustible materials. It is of the greatest importance
that this fireplace and vent system be Installed only in accordance with these Instructions.
Caution Requirements
The top. back and sides of the fireplace are defined by
standoffs. The metal ends of the standoff may NOT be
recessed into combustible construction.
WARNING
Fire hazard Is an extreme risk
if these clearances (air space) to combustible materials are not
adhered to. It is of greatest importance that this fireplace and vent
system be installed only in accordance with these instructions.
Clearance:
Dimension
Measured From:
A: Mantel Height (min.)
1T (330mm)
Top of Fireplace Opening
B: Sidewall (on one side)
8' :203mm:
Side of Fireplace Opening
C: Ceiling
(room and/or alcove)
22" (559mm)
Top of Fireplace Opening
D: Mantel Depth (max.)
1r (330mm)
22" Above Fireplace Opening
E: Alcove Width
844 (2134mm)
Sidewall to Sidewall (Minimum)
F: Alcove Depth
36' (914mm)
Front to Back Wall (Maximum)
G: From Floor
27' (686mm)
Top of Fireplace Opening
Note:
0"
No hearth required
E
Alcove
r
ife Release Kit have different clearance
The HeatWave Duct Kit and the Heat
iwites.•S
and framing requirements. check the
HeetWaveand Heat Release manual
for details.
lint Release MI
Flue Clearances to Combustibles
Horizontal Top
Horiztonal . Side
Horiztonal • Bottom
Vertical
3"
2"
Passing through wall.
floor/ceiling
when
firestop is used.
F 1 2"
Installed close
to ceiling.
r
Regency Horizon"' HZ40E Gas Fireplace
EFTA00301429
INSTALLATION
MANTEL CLEARANCES
Due to the extreme heat this fireplace emits, the
mantel clearances are critical. Combustible mantel
clearances from top of front facing are shown in the
diagram on the right.
Note: Ensure the paintthat Is used on the mantel
and the facing is"high quality" orthe paint
may discolour.
14 12 10 8
6
4
2 0
ll
l l l l l
t l l t l l l
26-
20 -
10-
-
0
To Unit
Base
1" (25mm)
22"(559mm)
2T
Top of
Fireplace
Opening
Combustible Material
Metal Stud
(On Edge)
Facing
Non-combustible
17
Standoff
4
MANTEL LEG CLEARANCES
Combustible mantel leg clearances as per diagram:
5-11/16"(144mm
Non-Combustible
Allowable mantel
legp rojection
Regency Norizonm 14240E Gas Fireplace
EFTA00301430
INSTALLATION
UNIT ASSEMBLY
PRIOR TO
INSTALLATION
The nailing Strips must be correctly positioned and attached before unit is
slid into position.
NAILING STRIPS
The nailing strips come attached to the unit. There is 1 plate on each side.
on the top. There also two on the bottom.
The top and side nailing strips are secured to the framing. The bottom
nailing strips are
IMPORTANT NOTE
Framing depth measurement is noted with the nailing strips
set as far forward on the firebox as possible. The nailing
strips can be adjusted back up to 1 -1/24 to allow for varying
thicknesses in noncombustible material & wall finishes.
INSTALLATION ACCESS PANEL
The unit is equipped vMh a removable access panel for pre-finish installation
of optional components
this panel is located on the lower front face.
1) Remove lower front face nailing strips (2 screws per nailing strip).
2) Remove 8 screws to remove access panel.
3) Easier access to gas connection with panel removed.
4) Install any optional components with access panel removed.
5) Reinstall access panel with B screws and lower front face nailing strips
(2 screws per strip) - prior to installing any facing material
Note: Access panel is no longer usable once fadng material installed.
Installation Access Panel
FRONT FACE NAILING STRIP
INSTALLATION
Required when the combined facingilinishing material is 112'.
If using material which is thicker than 1/2'. the nailing strips are not
required and should be removed and discarded.
1) The 5 front nailing strips are only used if the facing/finishing material
is a combined 1/2' in thickness. This enables the fadng and finishing
materials to be securely fastened to a solid surface.
2) Follow instructions on non-combustible facing installation for pre-
drilling holes prior to attaching the noncombustible material supplied
with this unit.
3) The sidettop nailing strips which are attached to this unit will also need
to be adjusted. See Framing and finishing in this manual.
Lower front nailing strips
Regency Horizon"' HZ40E Gas Fireplace
EFTA00301431
INSTALLATION
FRAMING DIMENSIONS
Framing
DimensiOnS
B
1)
G
J
K
L
* Framing depth measu Omani is noted with the nailing strips set as far forward on the firebox as possible.
The nailing ships can be adjusted back up to 1- to allow for varying thicknesses in non-combustible
material & wall finishes.
Description
Framing Height
EMMIIML_
Framing Depth*
Minim
Coiner Wall Depth
Comer
Vent Centerline Height
Nona
Gas Connection Opening Height
Gas CSE
Gas Connection Inset
Gas Connection Opening Width
HZ40E IME
42' (1067mm)
taa
C1 Horizontal Vent 19-7116' (495mm)
C2 Vertical Vent 23-7/16" (596mm)
Vertical rise -terminating horizontal
57-18" (1457mm)
36 -
(921mm)
1r (432m01)
2" 151mm)
4 - 3/16" (106mm) -- al
8. 5116' (211mm)
a2"
(89mm)
Note: Al other framing may
be of wood construction.
Regency Hodzonm FiZ40E Gas Fireplace
EFTA00301432
INSTALLATION
NON-COMBUSTIBLE REQUIREMENTS
AI three pieces (top. 2 sides) are now supplied to meet the non combustible requirements. Previously only the top was supplied
Calcium silicate board is a high • grade material
with cement. quartz. natural and selected
minerals as the main raw materials. It is widely
used for partitions and ceilings in buildings.
It is fire proof and earthquake proof.
II finishing the wall above the unit with materials
such as tile, brick, marble. etc. non-combustible
board available from the building supply store
can be used.
Note: Calcium Silicate is 1/2' thick
Metal Stud
g
• •
•
g
;TA
nE
•
10'
(252=1)
el In
5-11/16-
(144mm)
51.5116' (1303mm)
NON-COMBUSTIBLE FACING INSTALLATION
Caution: The noncombustible board supplied with this unit can
be damaged if dropped or struck. Handle with care.
1) Using drywall screws • secure non combustible material
around unit, framing and top nailing strip every 6 inches.
Important Note: To avoid cracking the board • pre-drill holes prior to
securing to unit/ framing.
2) Wipe any debris/dust from the non combustible
material and drywall.
3) Prior to taping and mudding it is highly recommended
to prime the facing using a quality primer. This will
ensure proper adhesion of both the tape and mud.
The supplied board is very porous.
4) Tape the seams using a mesh type tape.
5) Mud seams as normal. We recommend using a
product called Durabond high strength compound • for the first coat.
This product can be found at any hardware store.
Mud must be cured as per manufacturers recommendations.
6) Prime wall for a second time for proper adhesion of paint
7) Paint walls using a high quality paint which will withstand
the high temperatures being emitted from this appliance.
Non combusIblie board
Apnea v41b unt
1'
Metal Stud (header)
on edge
►,
A
Metal Stud
•
gen.'s...Ana bawd
seised vein um.
14:0 combust/So loud
MUS1 BE PRIMED.
Regency Horizon"' HZ40E Gas Fireplace
EFTA00301433
INSTALLATION
FRAMING & FINISHING
1) Frame in the enclosure for the unit with framing material.
IMPORTANT: The framed opening must be of non-combustible
material.
Note: When constructing the framed opening, please ensure there
Is access to Install the gas lines when the unit is Installed.
2) For exterior walls, insulate the enclosure to the same degree as the
rest of the house, apply vapour barrier and drywall. as per local instal-
lation codes. (Do not Insulate the fireplace Itself.)
WARNING: Failure to insulate and add vapor barriers to the inside
of the exterior wall will result in operational and performance
problems including, but not limited to: excessive condensation
on glass doors, poor flame package, carbon, blue flames etc.
These are not product related issues.
3) The unit does not have to be completely enclosed in a chase. You
must maintain clearances from the vent to combustible materials: See
"Clearances" section. Combustible materials can be laid against the
side and back standoffs and the stove base.
4) Noncombustible material (ie. tile, slate. etc) may be brought upto and
overlap the unit (top and bottom) ensuring that the maximum thickness
does not go beyond the 1.112" as shown in the diagram below. The
faceplate will not be able to be mounted if finished material is beyond
1 -1 /Y.
1-'4" (38mm)
Edge of __
flange on
fireplace
1/2" required
between faceplate
+ finished wall
1:W (38mm)
Nailing Strip
IMPORTANT: 112" gap required between faceplate and finished wall when
using 4 pee. Faceplate (Part # 256.924, 256.926, 256.927)
5) If material such as brick, stone. etc extends past the faceplate depth (1.112-).
when finishing around the faceplate, the minimum opening dimensions noted
below must be adhered to ensuring for the removal of the faceplate and for
the safe operation of this appliance.
NOTE: Spacing of 1" around the completed surround must be adhered to.
52.31C
I
is.
if
Unit shown with 4 piece faceplate
47- .1115-
Unit shown with inner and outer door frame
I
.
I E LTT i_
39-13/16" IL
•
to
eb
Unit shown with inner door frame only
Regency Norlzonm 14240E Gas Fireplace
EFTA00301434
INSTALLATION
FRAMING & FINISHING
1/2"
1"
Nailing Strip
1/2 " Forward
3" (flush)
Nailing Strip
1' Forward
Unit
Unit
` —Nailing Strip
Flush w/unit
Factory Set
Note:
Depending on the material used for finishing, the nailing
strips must be set accordingly so that the finished material
is always at the 1.1/2' edge of the flange.
I
1
4
E
V
ZO?
E
CAn
10'
(252mm)
NON-COMBUSTIBLE REQUIREMENTS
Metal Stud (header)
on edge
►
Metal Stud
A
•
5-11/16"
51-5/15' (1303mm)
May be combustible (ie. 1/2"dryw
•
33.13416• (859mni)
(144mm)
Regency Horizon"' HZ40E Gas Fireplace
EFTA00301435
INSTALLATION
EXTERIOR VENT TERMINATION REQUIREMENTS
BITI0RINO110
Vent Termination
Q Air Suppry Owlet
E Area whet* terminal a nol perrritted
Minimum Clearance Requirements
Canada'
USA2
A
Clearance above grade. veranda. porch. deck. or balcony
12130cm)
12130cm)
8
Clearance to window or door that may be opened
12130cm)
cr (23crn)
C
Clearance to permanently closed window
'
0
Vertical clearance to ventdated soffit located above the ternwial within a horizontal distance of 2 feet (6Icm)
from the center Ike of the terminal (check with the local code)
19148cm)
19148cm)
E
Clearance to unventiLated soffit
19148cm)
19 '(48cm)
F
Clearance to outside corner: with AstroCap Termination Cap.
7118cm)
7118cm)
Clearance to outside corner: with all other approved Termination Caps.
13133cm)
13133cm)
G
Clearance to inside corner: with AstroCap Termination Cap
7118cm)
71113cm)
Clearance to inside corner: with all other approved Termination Caps.
13133cm)
13 133cm)
H
Clearance to each side of center line extended above metedregulator assembly
36 190cmr
J
Clearance to service regulator vent outlet
36'(90cm)
'
K
Clearance to non-mechanical air supply inlet to building or the combustion air inlet to any other appliance
12130cm)
r (23cm)
L
Clearance to a mechanical air supply inlet #3' (91cm) above if withal 10' (3rn) horizontally.
7211.8m)
36•(90cn)e
fA
Clearance above paved sidewalk or a paved drweway located on public property
84 12.1m)!
'
N
Clearance under veranda, porch. deck. or balcony
12130cm),
'
' In accordance with current CSA 8149.1. Natural Gas and Propane Installation Code
2 In accordance with the current ANSI Z223. liNFPA 54. Nat,onal Fuel Gas Code
+A vent shall not terrneste directly above a sklewak or paved driveway which is located between two single family dwellings and serves both dwellings
$ Permitted only if veranda. porch, deck. or balcony S fully open on a minimum of two sides beneath the floor
• Clearance in accordance with local installation codes and the requirements of the gas supplier
a 3 feet (91cm) within a height of 15 feet (4.5m) above the meter 1 regulator assembly
b 3 feet (91cm) above - it within 10 feet (3m) horizontally
Regency Hertz:mini I4Z40E Gas Fireplace
EFTA00301436
INSTALLATION
4" X 6-5/8" RIGID PIPE
CROSS REFERENCE CHART ONLY
Components from different Manufacturers may not be mixed. Not All Rigid Pipe components are available directly from FPI.
Oescriptien
Simpson
Owed Wm pia
SeIldrk
Direst Terrr
American Metal
ProductsID
AmOtIvial Died
Meial-Fabm
Sure Seel
SecurRy
Secure-Vent
ICC Excel
Med
8 Pipe Length-Galvanized
460VA-06
401-6
WA
406
SV4L6
TC-4DL6
8 Pipe Length-Black
460VA-069
40T-65
WA
4065
SV4L86
TC-40L6B
7- Pipe Length-Galvanized
N/A
WA
407
WA
WA
WA
7- Pipe Length-Week
WA
WA
4075
WA
WA
N/A
9" Pipe Length-Galvanized
46DVA-09
40T-9
WA
WA
WA
WA
9" Pipe Length-Week
460VA-095
4DT.95
WA
WA
WA
N/A
12' Plpe Length-Galvanized
46DVA-12
40T-12
4012
4012
SV4L12
TC-40L1
I2- Pipe Lengui-Black
460VA-125
40T-125
40125
40125
SV4L812
TC-II)Liti
18' Pipe Length-Galvanized
46DVA-18
407-18
4018
4018
SV4LA
TC-40L18
1W Pipe Length-Black
46DVA-18B
40T-185
40185
40185
SV4LA
TC-4DL 18B
24' Pipe Length-Galvanized
48WA-24
401-24
4024
4020
SV4L24
TC-40L2
24' Pipe Length-Black
460VA.245
401.245
40245
40245
SV4L524
TC-40L2B
36' Pipe Length-Galvanized
480VA-36
40T-36
4036
4036
5V4138
TC-40L3
36' Pipe Length-Black
46DVA-365
401-366
40366
40365
SV4L536
TC-40L36
48' Pipe Length-Galvanized
480VA-48
40T-48
0048
4048
SV4L48
TC-40L4
4W Pipe Length-Black
46DVA-486
401-48B
40486
40485
SV4L548
TC-40L46
60' Pipe Length-Galvanized
48WA-60
40T-60
WA
N/A
WA
N/A
EC Pipe Length-Black
460VA-606
401-60B
N/A
WA
WA
WA
Adjustable Length 7 -IT-Galvanized
WA
WA
N/A
4DAL
WA
TC-ODLT
Adustabte Length T. I 0' -Black
WA
WA
WA
4DAL5
WA
TC.4DLTB
Adjustable Length T -Galvanized
WA
WA
4D7A
WA
WA
N/A
Adusiable Length T'-Black
WA
WA
407AB
WA
WA
NA
Extension PO 8-1/t-Galvanized
460VA-08A
WA
N/A
WA
WA
N/A
Extension Pipe El-VT-Black
46DVA-OBAB
WA
N/A
WA
WA
NA
Adjustable Length It -Galvanized
WA
WA
4012A
WA
SVOLA12
N/A
Ackosiable Length 12'-Slack
WA
WA
4012A
WA
SV4L5Al2
NA
Extensko Pipe 16*-GaNailzed
460VA-16A
WA
N/A
WA
WA
NIA
Extension Pipe 16'-Black
46DVA-I6AB
WA
WA
WA
WA
WA
45' El3ow-Galvantzed
46DVA-E45
407-EL45
4045L
WA
N/A
TE-40E45
45' Wbow-5lack
460VA.E456
401-EL455
40T-EL45B
VA
WA
TE-40E458
45' Elbow Swivel-Galvanized
See 460VA-E45
N/A
WA
41345L
SV4E45
WA
45' Ebow Swwel.Black
See 46DVA.E45B
WA
WA
4045L5
SV4EB45
WA
90' Elbow-Galvanized
460VA-E90
401-EL9OS
40TEL9OS
N/A
N/A
TE-40E90
90' Ebow-Black
460VA.E936
40T-EL90S5
40T-EL90S5
WA
SV4EBR90.1
TE-40E90B
90' Elbow. SwIvel.Galvantzed
See 460VA-E90
N/A
WA
40901.
SV4E90-1
WA
90' Elbow. Swivel.Black
See 46DVA.E9OB
WA
WA
4090L5
SV4E690-1
WA
90' Starter Elbow. Swivel-Gab/awed
N/A
N/A
WA
4090A
N/A
WA
Adaptor'
WA
WA
WA
4090L
WA
WA
Ceiling Support
WA
407-CS
4DFSP
40SP
SV4SD
7E-4DE45
Cathedtal Support Box
46DVA-CS
40T-CSS
401156
40RS
SV4CSB
TE-41)E4515
Wal Support/Band
46DVA-WS
407-WS1B
4DWS
4DWS
SV4BM
WA
Ofiset Support
46CP/A.ES (MA . FPI)
40T-OS
NSA
WA
SV4SU
WA
Wal Thanble-Black
46DVA-WT
407-WT
40W7
40W1
SV4FISM
7E-4DE90
Wal Trimble Suppcit/Ceiling Supped.,
460VA•DC
WA
NSA
NA
SV4PF
TE-40E90B
Areal* Spacer
46DVA-FS
407-FS
4DFSP
4DFS
SV4BF
_
WA
—
Trim Pate-Back
WA
4DT-TP
4DEPB
40CP
SV4LA
WA
C
Regency Horizon"' HZ40E Gas Fireplace
EFTA00301437
INSTALLATION
Description
Simpson
Deceived Pro*
Selldrk
Direct Temp"
American Metal
Products:ID
Arnehwer Oita
Metal-Fatd"
suet Sod
Security
Secure-Were
ICC Excel
Circa
Attc NtolatKin She
2'
46CNA.IS MAO FPI
NrA
4DAIS12
WA
SV4RSA
TA
Attic Insulation Shield - Cold °khakis 36"
N/A
N/A
ODAIS12
N/A
N/A
TM-4AS
Basic Horizontal Termination Kit (A)
Disc.
4DT.HKA
4DHTK2
4W-1'MA
SV-SHK
NA
Horizontal Termination Kit (B)
46DVA-KMA
tOwind mai:fent;
401-ZIKB
4DHTK1
4DHTI(B
SV-HK
HA
Vencal Terminatim Kil
Ds.
4C.T.oKC
4DHTK
fo:r7K
SlbFK
NA
High Wind Verlical Cap
46DVA-VCH
WA
WA
Ni'.
WA
TM-4VT
nigh Wird Horizontal Cap
46DVA.HC
NA
TA
TVACHT
Horizontal Square Termination Cap
See 46DVA-HC
4DT-HiSC
4DHC
4DHT
SV4CHC-I
TA-4MT
Vented Termination Cap
461YVA.vC
4DT.FP/C
4DVC
4DVT
SV4CGV.I
TM-4V7
Storm Collar
46DVA-08A
4DT-SC
4DSC
4DSC
SV4FC
TA-SC
Adjustable Flashing OM 24212
460VA-F6
4DT-ST t4
40125
405114
SV4STCI4
TF-4FA
Adjustable Mashing 6/12-12/12
46DVA-FLA
4DT-ST36
4D355
4DST36
SV4STC38
TF-4F0
Vinyl &ding Standen
46DVA.VSS
4DT-VS
NrA
4DVS
SV4VS
PA-VSS
Vinyl Siding Shield Plate
N/A
4DT-VSP
N/A
WA
SV4VS
N/A
Snorkel Termination 14'
46DVA.SNKL
TA
WA
IFA
NIA
T.4-43714
Snorkel Termination 36-
N/A
NIA
WA
WA
WA
114-4S138
Redick!' Disk
NA
NA
NR
WA
TA
TM-4DS
Extended Vertical Termination Cap
WA
WA
N/A
NM
WA
N/A
Chimney Corweision Kt A (USA only)
46DVA.KCA
Ni
WA
NrA
TA
TM-4CA6
Chimney Conversion Ki B (USA only)
46DVA-KCB
WA
N/A
NIA
WA
T.4-4CA7
Chimney Corrmesion 10 C (USA only)
46DVA.KCC
Na
NrA
WA
NIA
PARCAE,
Chimney Conversion Kt Masonry
(USA only)
46DVA10.4C
WA
WA
NIA
WA
N/A
Wal Fireslop
46DVA.V/FS
Na
NrA
WA
NIA
TM-SIR
Cando Flex Connectors
46DVARDF
WA
NfA
N/A
WA
WA
FPI
946-506P
Vary Guard (Optimal) for AstroCap
948-206
Vinyl Siding Shield for Riser VeM Terminal
510.994
Rigid Pipe Adaptor (Must use with all rig° piping)
946-200P
Vent Guard (Opting Ice Riser Vent Terminal
640-530:P
Mae( Vent Terminal
948-523V
AstroCap Horizontal Cap
946-605
Starter Calm Increaser C x 8-6/V to 5' x 8'
946.206
Vinyl Siding Standoff for AstroCap
Note: When using Metal-Fab Site Seal Rigid Piping - please note that the Adaptor (400A) must be used in ccojundko wkh FPI Rigid Pipe Adaptor (510-994).
Offset Pipe Selection: Use this table to determine offset pipe lengths.
Pipe Length
0-)
V x 6.5TVenting
For SpOCille insItuctions on venting °deponents - visit the
manulaclurers ivebsite ISIS below.
RLYI
L
.
/
/
/ /
I
I
'
I
I
Y
I
(X)
Kee CY)
0- (0mm)
4-718- (124mm)
13-7/8' (340mm)
Simpson Direct Vent Pro:
6" (152tivn)
V (933mm)
16-1 /2- (419twn)
Selkirk Direct-Temp:
9' (229mre)
10-L8- (257mm)
18-5/8" (473mm)
American Metal Predicts
12- (3116mm)
12-1/C (3l 1mm)
20-3/4- (527mm)
Metal-Fab Sure Seal:
24' (610mm)
20-5V (524mm)
29-1/8" (74Ornm)
Se:Andy Secure Vent.
— '
I
i
X
36- (914mm)
29- (737mm)
37-112- (953mm)
Industrial Chimney Company:
48' ( I 21 ginvn)
37-7/16' (951mm)
45-15116' i1167mm)
Note: Horizontal Leis DI vent must be love. or have a VC rise or every 1 fool of tort towards the letmimtlo
Never anew the vent to MIdCwaws d - this could CALM high temperatures and may present a posstl fire hazard.
Regency Horizon"' 14240E Gas Fireplace
EFTA00301438
INSTALLATION
VENT RESTRICTOR POSITION
Vent restriction is required for certain venting installations. see the diagrams in the "Venting
Arrangements' section to determine if they are required for your installation.
The Vent Restrictor plate is located on the inside top of the firebox.
To set the vent restriction as indicated in the venting arrangements diagrams, refer to the following instructions:
1) Remove the glass door - see instructions in this manual.
2) Remove the screws that hold the vent restrictor plate in place.
3) Adjust the vent restrictor plate to the required vent restrictor position as per the diagrams shown.
4) Once the vent restrictor plate is in the required position, secure with screws.
3.000
Set 0
(Factory set)
VENT RESTRICTOR
AT 3'
2000
I
Set 1
VENT RESTRICTOR
AT 2'
1500
u—kria-u
Set 2
VENT RESTRICTOR
AT 1.1/2'
1.000
Set 3
VENT RESTRICTOR
AT 1"
C
Regency HorlzonTM HZ40E Gas Fireplace
EFTA00301439
INSTALLATION
VENTING INTRODUCTION
The HZ40E uses the "balanced flue' technology Co-Axial system. The inner liner vents products of combustion to the outside while the outer liner draws
outside combustion air into the combustion chamber thereby eliminating theneed louse heatedroom air for combustion and losing warm room air upthechimney.
Note: These flue pipes must not be connected to any other appliance.
The gas appliance and vent system must be vented directly to the outside of the building, and never be attached to a chimney serving a separate solid fuel
or gas burning appliance. Each direct vent gas appliance must use its own separate vent system. Common vent systems are prohibited.
VENTING ARRANGEMENT FOR HORIZONTAL TERMINATIONS
The diagram shows all allowable combinations of vertical runs with horizontal terminations. using one 90° (two 45°elbows equal one 90° elbow). (Not including
the starting 45 elbow at the flue collar when using rigid venting.)
Note: Must use optional rigid pipe adapter (Part# 510-994) when using Rigid Pipe Venting Systems.
Horizontal (Feet)
0
2
4
6
0
10
12
I
I
I
!
I
I
Is
16
• 14I
a.0
12
E
10
0
u_
a—0
.0
6
stu
2—
>
0
•
VENT RESTRICTOR SETTING:
Vent restrictor lac ory se at Se 0.
Refer to the 'Vent Restrictor Position" section for details on how to change the vent restrictor from the factory setting of Set 0 to Set 1 if required.
Vent Restrictor
on Set 1
36.114' (921mm)
Ainimum Height
Recpinnent
14
16
18
20
Note: For horizontal terminations the Regency Direct Vent Flex System may be used for installations with a maximum continuous vent
length of up to 10 feet. If longer runs are required, rigid pipe must be used.
•
Maintain clearances to combustibles as listed in "Clearances" section
•
Horizontal vent must be supported every 3 feet.
•
Firestops are required at each floor level and whenever passing through a wall.
•
A vent guard should be used whenever the termination is lower than the specified minimum or as per local codes.
•
Flex system can only be used up to 10 feet - otherwise rigid venting must be used.
Regency Horizonw HZ40E Gas Fireplace
EFTA00301440
INSTALLATION
HORIZONTAL TERMINATIONS
FLEX VENT 4" X 6-7/8"
These venting systems. in combination with the HZ40E Direct Vent Gas Fireplace, has been tested and listed as a direct vent heater system by Warnock
Hersey/ Intertek. The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram in 'Exterior Vent Termination
Locations" section.
Regency. Direct Vent (Flex) System Termination Kits includes all the parts needed to install the 14240E using a flexible vent.
FPI Kit #
Length
Contains:
#946-513
2 Feet
1)
6.7/8" flexible outer liner (Kit length)
2)
4' flexible inner liner (Kit length)
3)
spring spacers
#946-515
4 Feel
4)
thimble
5)
AstroCap termination cap
6)
screws
7)
tube of Mill Pac
#946-516
10 Feet
8)
plated screws
9)
S.S. screws #8 x 1.1/2' drill point
Notes:
1) Liner sections should be continuous without any
Joints or seams.
2) Only Flex pipe purchased from Regency" may be
used for Flex installations
3) Horizontal vent must be supported every 3 feet.
4) Regency"Direct Vent System (Flex)Isonlyapproved
for horizontal terminations.
5) Flex system can only be used up to a maximum
continuous vent length of up to 10 feet. If longer
runs are required, rigid pipe must be used.
Wall Thimble
AstroCar
4" dia. flue pipe
Termination Cap
6-7/8"
(Part# 946-523/P)
173mm)
.5,
dia. Flue pipe
spring spacer
Vent Guard
(Part #946-506/P)
22
Regency Horizon"' HZ40E Gas Fireplace
EFTA00301441
INSTALLATION
HORIZONTAL TERMINATIONS
RIGID PIPE 4" X 6-5/8"
The minimum components required for a basic horizontal
termination are:
1 Horizontal Termination Cap
1 45° Elbow
1 Rigid Pipe Adaptor (510-994)
1 Wall Thimble
1 Length of pipe to suit wall thickness
(see chart)
Wall thickness is measured from the back standoffs to the inside
mounting surface of termination cap. For siting other than vinyl
furring strips may be used. instead of the vinyl siding standoff, to
create a level surface to mount the vent terminal. The Terminal
must not be recessed into siding. Measure the wall thickness
including furring strips.
If a Vinyl Siding Standoff is required (it must be used with vin I
siding), measure to outside surface of wall without siding and
add 2 inches.
r
i,",,ii:I I I inhi l ETii .n
li
Wall Thickness
(inches)
Vent Length Required
(inches)
4" • 5.1/2'
6'
7" • 8-1/2'
9'
10" - 11.1/2'
12"
9" - 14-1/2"
11" - 14-5/8' Adj. Pipe
1T - 23-1/2'
1r - 24' Adj. Pipe
WARNING-
Do not combine venting components from
different venting systems.
However use of the the AstroCar and FPI
Riser is acceptable with all systems.
This product has been evaluated by Intertek
for using a Rigid Pipe Adaptor in conjunction
with Duravenl Direct-Vent. Selkirk Direct-Temp.
Ameri Vent Direct Venting, ICC Excel Direct
and Security Secure Vent systems. Use of
these systems with the Rigid Pipe adaptor is
deemed acceptable and does not affect the
Intertek WHI listing of components.
Horizontal
Termination Cap
Vinyl Siding
Standoff (Optional
all Thimble
•
Adj.Pipe Length
4T Elbow
Rigid Pipe Adapter
When using Rigid Vent other than
Simpson 0ura-Vent, 3 screws must be
used to secure rigid pipe to adaptor.
Vent Guard
(Part #946-506/
The FPI AstroCapw and FPI Riser Vent terminal are certified for installations using FPI venting systems as well as Simpson Dura-Vent• Direct Vent.
American Metal Products Ameri Vent Direct Vent. Security Secure Venr. ICC Excel. Selkirk Direct-Temp. AstroCari is a proprietary trademark of FPI
Fireplace Products International Ltd. Dura-Vent® and Direct Vent are registered andfor proprietary trademarks of Simpson Dura-Vent Co. Inc.
Regency Horizon"' 14240E Gas Fireplace
EFTA00301442
INSTALLATION
HORIZONTAL TERMINATIONS
RIGID PIPE 4" X 6-5/8"
The diagrams below shows examples of horizontal termination arrangements using one, two. or three 90, ebows (two 45° elbows equal one 90° elbow)
1) A maximum of three 90° elbows are permitted (not Including the starting 45°elbow at the flue collar when using rigid venting).
2) Minimum distance between elbows is 1 ft. (305mm).
•
Maintain clearances to combustibles as listed in the "Clearances" section.
•
Horizontal vent must be supported every 3 feet.
•
Firestops are required at each floor level and whenever passing through a wall.
•
Must use optional rigid pipe adaptor (Part# 510-994) when using rigid pipe vent systems.
•
A vent guard should be used whenever the termination is lower than the specified minimum or as per local codes.
•
Flex system can only be used up to 10 feet - otherwise rigid venting must be used.
Straight Out Horizontal Venting
Diagram 1
center
of hole
•
Please note the minimum centerline for
basic install shown above.
Regency Horizon"' HZ40E Gas Fireplace
EFTA00301443
INSTALLATION
Horizontal Venting with Two (2) 90° Elbows
One
elbow = Two 45° elbows.
Option
V
H + H1
Withtheseoptions. maximum
A)
1' Min.
3' Max.
total pipe length is 28 feet
with minimum of 6 teel total
B)
2' Min.
4' Max.
vertical and maximum 8 feet
C)
3' Min.
5' Max.
total horizontal.
D)
4' Min.
6' Max.
Pleese note minimum 1
loot between 90° elbows is
E)
5' Min.
7 Max.
required.
F)
6' Min.
8' Max.
Restrictor Position Set 0 (factor)/ sening)
Horizontal Venting with Three (3) 90° Elbows
One 90° elbow = Two 45° elbows.
Option
H
V
Hatt+H2 With these options.
maximum total pipe
length is 28 feet with
of 11 teat
minimum
total vertical and
maximum 9 foet total
horizontal.
Plees,
note
minimum 1 loot
between90°elbows
Is required.
A)
1' Max.
1' Min.
3' Max.
B)
2' Max.
3' Min.
5' Max.
C)
3' Max.
5' Min.
6' Max.
D)
4' Max.
7' Min.
7' Max.
E)
5' Max.
9' Min.
8' Max.
F)
6' Max.
11' Min.
9' Max.
H2
Restrictor Position Set 0 (lactory setting)
Horizontal Venting with Two (2) 90° Elbows
One
elbow = Two 45° elbows.
Option
H
V
H4411
With these options,
maximum total pipe
Iength Is 28 feet with
minimum of 8 feet total
and maximum
8 feet total horizontal.
Ppielaosoetnotmin
betwnimg
elbows is required.
A)
1' Max.
1' Min.
3' Max.
B)
2' Max.
2' Min.
5' Max.
C)
3' Max.
4' Min.
6' Max.
D)
4' Max.
6' Min.
7' Max.
E)
5' Max.
8' Min.
8' Max.
Restnctor Position - Set 0 (factory setting)
Regency Horizon*" HZ40E Gas %oplas°
25
EFTA00301444
INSTALLATION
Horizontal Venting with Three (3) 90° Elbows
One 90' elbow= Tvo 450 elbows.
Option
V
H
V+V1
H+H1
With !hase options,
maximum total pipe
lenath is 28 feet with
A)
2' Min.
1' Max.
3' Min.
4' Max.
B)
3' Min.
2' Max.
4' Min.
5' Max.
totaln uvrite rtlitc at r atenectl
lriloVizimonilail.9 feet total
Please
note
minimum I kun
between 90' elbows
Is requIred.
C)
4' Min.
3' Max.
6' Min.
6' Max.
D)
5' Min.
4' Max.
8' Min.
7' Max.
E)
6' Min.
5' Max.
10' Min.
8' Max.
F)
7' Min.
6' Max.
12' Min.
9' Max.
Restnctor Position Set 0 (tadog setting)
Regency Horizonn, HZ40E Gas Flreplace
EFTA00301445
INSTALLATION
VERTICAL TERMINATIONS
RIGID PIPE 4" X 6-5/8"
The minimum components required for a basic vertical
termination are:
Vertical Termination Cap
45° Elbow
Rigid Pipe Adaptor (510.994)
Ceiling Firestop
Flashing
Storm Collar
Length of pipe to suit wall thickness
(see chart)
Galvanized pipe is desirable above the roofline due to its higher
corrosion resistance. Continue to add pipe sections through the
flashing until the height of the vent cap meets the minimum height
requirements specified in Dia.4 or local codes. Note that for steep
roof pitches. thevertical height must be increased. A poor draft, or
down drafting can result from high wind conditions near big trees
or adjoining roof lines. in these cases, increasing the vent height
may solve the problem.
Roof Pitch
Minimum Vent Heigh
Feet
Meters
flat to 7112
2
0.61
over 7/12 to 8/12
2
0.61
over 8112 to 9/12
2
0.61
over 9/12 to 10/12
2.5
0.76
over 10/12 to 11/12
3.25
0.99
over 11/12 to 12/12
4
1.22
over 12/12 to 14112
5
1.52
over 14/12 to 16/12
6
1.83
over 16,12 to 18/12
7
2.13
over 18,12 to 20/12
7.5
2.29
over 20/12 to 21/12
8
2.44
Vertical Terminal
Storm Collar
Flashing
Ceiling Firestop
WARNING.
Do not combine venting components from different venting systems.
However use of the the AstroCapw and FPI Riser is acceptable with all systems.
This product has been evaluated by Intertek for using a Rigid Pipe Adaptor in conjunction
with Duravent Direct-Vent. Selkirk Direct-Temp.Ameri Vent Direct Venting.ICC Excel Direct
and Security Secure Vent systems. Use of these systems with the Rigid Pipe adaptor is
deemed acceptable and does not affect the Intenek WHI listing of components.
Pipe Length
Rigid Pipe Adapter
When using Rigid Vent other than
Simpson Dura-Vent. 3 screws must be
used to secure rigid pipe to adaptor.
The FPI AstroCar and FPI Riser Vent terminal are certified for installations using FPI venting systems as well as Simpson Dura•VenP Direct Vent.
American Metal Products Amen Vent Direct Vent. Security Secure Ventt. ICC Excel. Selkirk Direct-Temp. AstroCap1° is a proprietary trademark of FPI
Fireplace Products International Ltd. Oura-Vent and Direct Venl are registered and/or proprietary trademarks of Simpson Oura.Vent Co. Inc.
Regency Horizon,'" HZ40E Gas Fireplace
EFTA00301446
INSTALLATION
H
VENTING ARRANGEMENT FOR VERTICAL TERMINATIONS
Vertical Venting with One(1) 90° Elbows (1 - 90° 2 - 45°)
Theshadedareainthediagramshowsallallowablecombinations
of straight vertical and offset to vertical terminations, using one
90° elbow, with Rigid Pipe Venting Systems.
Two 45° elbows equal to one 90° elbow. not including the
starting 45° elbow at the flue collar.
Vent must be supported at offsets.
Minimum distance between elbows is 1 ft. (305mm).
Maintain clearances to combustibles as listed In the
"Clearances" section.
Horizontal vent must be supported every 3 feet.
m—
a-
33
Firestops are required at each floor level and whenever
passing through a wall.
Must use optional rigid pipe adaptor (Part# 510.994)
when using rigid pipe vent systems.
Refer to the "Vent Restrictor Position" section for
details on how to change the vent restrictor from the
factory setting of Set 0 to Set 1 or Set 2 if required.
14
a —
a —
I —
I —
2 —
a
Horizontal (Feet)
a
a
a
el
I
I
I
A
Vert Rosinaor on
E
Vett Rostrictor on Sot 2
iazt,_
4—I
M.
Maim." @Nad ppe
between elbass 12'(306m n(
Vent Rosinclor on Set I
M. IC tat (cialerine lo conk**
11
ff
I
i t
Regency Horizon"' HZ40E Gas Fireplace
EFTA00301447
INSTALLATION
VERTICAL TERMINATION
WITH CO-LINEAR FLEX SYSTEM
THE APPLIANCE MUST NOT BE
CONNECTED TO A CHIMNEY FLUE SERV-
ING A SEPARATE SOLID FUEL
BURNING APPLIANCE.
This appliance is designed to be attached to
two 3" (76mm) co-linear aluminium flex running
the full length of the chimney. See the 'Venting
Arrangements Vertical Terminations' Section for
minimum and maximum heights.
Required Parts:
Part #
Description
946.529
Co-linear DV Vertical
Termination Cap
948.305
3" Flex 35 ft.
946.563
Co-Axial to Co-LinearAdaptet Kit
which contains the following:
Co-linear Flex Adapter
Outer Pipe
Inner Pipe Adapter
510.994
Rigid Pipe Adaptor
46DVA-E45 450 Elbow
Alternate Approved Caps
46DVA-VC
Vertical Termination Cap
46DVA-VCH High Wind Cap
46DVA-GK
r Co-linear Adapter with flashing
Masonrychimneys may takevariouscontourswhichthe flexiblelinerwill accommodate. However.
keep the flexible liner as straight as possible. avoid unnecessary bending.
The Air Intake pipe must be attached to the inlet air collar of the termination cap.
Co-linear DV
Vertical Termination
Cap # 946-529
A maximum
of two certified
joiner kits
may be used
per length.
#948-305
35ft (11m)
Exhaust
Flue
Outer
Pipe
with Kit#
946-563
Pipe Length
N4
Rigid Pipe Adapter
# 510-994
45° Elbow
Inner Pipe
Adapter
with Kit#
946-563
Flex Liner
Air Intake
Co-Linear
Flex
Adapter
with Kit#
946-563
Regency Horizon" HZ40E Gas Fireplace
29
EFTA00301448
INSTALLATION
VERTICAL TERMINATIONS
RIGID PIPE 4" X 6-5/8"
•
Two 450 elbows equal to one 90° elbow. Maximum of four 45° elbows allowed, not including the starting 45°elbow al the flue collar.
•
Vent must be supported at offsets.
•
Minimum distance between elbows is 1 ft. (305mm).
•
Maintain clearances to combustibles as listed in the "Clearances" section.
•
Horizontal vent must be supported every 3 feet.
•
Firestops are required at each floor level and whenever passing through a wall.
•
Must use optional rigid pipe adaptor (Part./ 510-994) when using rigid pipe vent systems.
Vertical Venting with Two (2) 90° Elbows
One 90' elbow = Two 45° elbows.
Option
V
H
V+V1
With these options.
maximum total pipe
length is 30 feet with
vmeliliiienlaulmanodf rn6armtutomtal
feel total horizontal.
Please note minimum
I loot between 90°
elbows is required.
A)
i• min. 4' Max.
2' Min.
B)
2' Min. 5' Max.
3' Min.
C)
3' Min. 6' Max.
4' Min.
D)
4' Min. 7' Max.
5' Min.
E)
5' Min. 8' Max.
6' Min.
Restrictor Position Set 0 (factory setting)
Vertical Venting with Two (2) 90° Elbows
One 90° elbow = Two 45° elbows.
Option
H + Ht
V
With theseoptions. maximum
A)
2' Max.
Z Min.
total pipe length is 30 feet
with minimum of 6 feet total
vertical and maximum 6 feet
total horizontal.
Please note minimum I
foot between 90° elbows is
required
B)
3' Max.
a Min-
C)
4' Max.
4' Min.
D)
5' Max.
5' Min.
E)
6' Max.
6' Min.
For additional vertical venting with
2 x 90° elbows. refer to 'Rigid Pipe
Venting Arrangements" Section.
Restrictor Position Set 0 (factory setting)
30
Regency Horizon*" HZ40E Gas Fireplace
EFTA00301449
INSTALLATION
Vertical Venting with Three (3) 90° Elbows
One 90° elbow = Two 45° elbows.
Option
H
V
H + H1 V + V1 With these options. max. total
pipe length is 30 feet with min.
of 11 feet total vertical and
max. 7 feet total horizontal.
Please note min. 1 loot
b
etween
required.
90, elbows is
A)
t• Max. t• Mm. .5 Max. I .5 min.
B)
2' Max. 2' Min. 4' Max. I 5' Min.
C)
3' Max. 3' Min.' 5' Max. 7' Min.
D)
4' Max
4' Min.
E)
5' Max
5' Min.
61 Max. 9' Min.
7 Max. ' 11' Min.
Restrictor Position Set 0 (factory setting)
Vertical Venting with Three (3) 90° Elbows
One 90, elbow= Two 45, elbows.
Option
V
H + H1 V + V1 withthese options, max. total
pipe length is 30feet with min.
of 10 feet total vertical and
max. 8 feet total horizontal.
Please note min. 1 loot
between 90° elbows Is
required.
A)
Z Min. 3' Max. 4' Min.
B)
3' Min. 4' Max. 6' Min.
-- CF. 4. Mm. 5' Max. 7' Min.
D)
5' Min. 6' Max. 8' Min.
E)
6' Min. 7' Max. 9' Min.
10' Min
F)
7' MunriMax.
Resuictor Position - Set 0 (factory setting)
Regency Horlzonm 11240E Gas Fireplace
EFTA00301450
INSTALLATION
Horizontal Distance (Feet)
VENTING ARRANGEMENTS - VERTICAL TERMINATIONS
with Co-linear Flex System for both
Residential & Manufactured Homes
into Masonry Fireplaces
Vertical Height (fe
35—
O
0
E
E
IF
Vent Restrictor
Set 2
r
C
•
ao
35' (10.7m) Max.
•
x
2
•
7OSg
I 1 1 I I
I
Horizontal Distance (Feet)
Vent Restrictor Set 1
The shaded area in the diagrams show
the allowable vertical terminations when
using two- 3" co-linear aluminium flex
and 4 x 6-5)8" rigid pipe.
35
Vertical Height (feet)
CV
1
Ven Restrictor
Set 2
8
E
lV
•
•
A
--EE
E
Cl
to
0
E
2
Combined max. of 16' M
I I I
I I I
Horizontal Distance (Feet)
•
•
Vent Resbictof Set 1
Regency Horizon"' HZ40E Gas Fireplace
EFTA00301451
INSTALLATION
UNIT INSTALLATION
WITH HORIZONTAL
TERMINATION
4" X 6-5/8"
VENTING
(Rigid Vent Systems)
Minimum Vent Clearances
to Combustibles
' Clearances noted below must be maintained:
except when passing through a wall. ceiling of al the
termination where the use of a firestop or wall thimble
reduces clearance to 1 -112' (38mm).
Horizontal Top'
3" (76mm)'
Horizontal Side
2 " (51mm)
Horizontal Bottom
2" (51mm)
Vertical Vent
2" (51mm)
Below are the recommended framing dimensions
(inside measurements) for the
4" x 6-5/8'
rigid vent terminations - for use with a firestop or
wall thimble.
Recommended Framed Opening
Size
Vent Size
Framing Size
ri" z 6 - 5/8'
10' x 10'
Install the vent system according to the
manufacturers instructions included with the
components.
1) Set the unit in its desired location. Check to
determine if wall studs or roof rafters are in
the way when the venting system is attached.
If this is the case, you may want to adjust the
location of the unit. Rough in the gas preferably
on the right side of the unit and the electrical
(junction block is on the left side) on the left.
2) Direct Vent pipe and fittings are designed with
special twist-lock connections to connect the
venting system to the appliance flue outlet. A
twist•lock appliance adaptor is required.
3) In conjunction with theApproved Vent system.
install the adaptor after the unit is set in its
desired location. Put abeadof high temperature
silicone inside the outer section of the adapter
and a bead of Mill Pack on the inner collar. Slip
the adapter over the existing inner and outer
flue collar. Fasten to the outer collar only with
the 3 supplied screws (drilling pilot holes will
make this easier).
4) Level the fireplace and fasten it to the framing
using nails or screws through the top and side
nailing strips.
Female
SE
Locking
•
Lugs
Male
Pease>
Lugs
Diagram I
5) Assemble the desired combination of pipe and
elbows to the appliance adaptor and twist-lock
for a solid connection.
Note: Forbestresultsandoptimumperfonnance
with each approved venting system, it is
highly recommended to apply "Mill-Pac•"
sealant (supplied) to every Inner pipe
connection. Failure to do so may result
in drafting or performance issues not
covered under warranty. Silicone (red
RTV) is optional.
Horizontal runs of vent must be supported every
3 feet (0.9meter). Wall straps are available for
this purpose.
6) Mark thevanforasquare hole.-see chart to left
for size. The center of the square hole should
line upwith the center•lineof the horizontal pipe.
Cut and frame the square hole in the exterior
wall where the vent will be terminated. See
diagram 2 for center line requirements.
If the wall being penetrated is constructed of
non-combustible material, i.e. masonry block
or concrete, an 8" (203mm) diameter hole is
acceptable.
Note:
a) The horizontal run of vent must be level, or
have a 1/4 inch rise for every 1 foot of run
towards the termination. Never allow the
vent to run downward. This could cause
high temperatures and may present the
possibility of a fire.
b) The location of the horizontal vent
termination on an exterior wall must meet
all local and national building codes,
Diagram 2
7) Ensurethat the pipe clearances to combustible
materials are maintained (Diagram 5). Install
the termination cap.
Note: if installing termination on a vinyl siding
covered wall, a vinyl siding standoff or
furring strips must be used to ensure
that the termination is not recessed into
the siding.
Siding
apply sealant
to all four sides
bolt Horizontal
— 4— Top to Vinyl Standoff
screws
Vinyl siding standoff
Wall Thimble
(required)
Diagram 5
The four wood screws provided should be
replaced with appropriate fasteners for stucco.
brick, concrete, or other types of sidings.
8) Beforeconnectingthehorizontal run of vent pipe
to the vent termination, slide the Wall Thimble
over the vent pipe. The wall thimble is required
for all horizontal terminations.
9) Slide the appliance and vent assembly towards
the wall carefully inserting the vent pipe into the
vent cap assembly. It is important that the vent
pipe extends into the vent cap sufficient6stance
so as to result in a minimum pipe overlap of
1-1/4 inches (32mm). Secure the connection
between the vent pipe and the vent cap.
10) install wall thimble in the center of the framed
hole and attach with wood screws (Diagram 7).
Diagram 7
Regency Horizon" HZ40E Gas Fireplace
a
EFTA00301452
INSTALLATION
UNIT INSTALLATION
WITH HORIZONTAL
TERMINATION
4" X 6-518"
VENTING
(Flex Vent Systems)
Minimum Vent Clearances
to Combustibles
• Clearances noted below must be maintained:
except when passing through a wall. ceiling or at the
termination where the use of a frestop or wall thimble
reduces clearance to v. (25mm).
Horizontal Tor
3" (76mm)"
Horizontal Side
2 " (51mm)
Horizontal Bottom
2" (51mm)
Vertical Vent
2" (51mm)
Below are the recommended framing dimensions
(inside measurements) or the 4" x 6.5/8" rigid
vent terminations - for use with a firestop or wall
thimble.
Recommended Framed Opening
Size
Vent Size
Framing Size
e x 6 - 5/8'
10" x 10'
1) Locate the unit in the framing, rough in the gas
(preferably on the right side of the unit). Locate
the centerline of the termination and mark wall
accordingly. Cut an square hole in the wall - see
chart (inside dimension).
Note: If Installing termination on a airline coy-
gyed wall. a vinyl sidina standoff or vinyl
1111011811llizamustlausgsltoensure that
the termination is not recessed into the
siding.
2) Level the fireplace and fasten it to the framing
using nails or screws through the nailing strips.
3) Assemble the vent assembly by applying Mill
Pacto the inner flue collarof thelermination and
slipping the inner flex liner over it at least 1.3/8"
(35mm). Fasten with the 3 screws (drilling pilot
holes will make this easier). Apply Mill Pac or
high temperature silicone to the outer flex pipe
and slip it over the outer flue collar of the vent
terminal at least 1.3/8"(35mm) and fasten with
the 3 screws.
NOTE: Horizontal sections must be supported
at Intervals not exceeding 3 feet (0.9
meter). (Flame picture and performance
will be affected by sags In the liner).
4) Separate the 2 halves of the wall thimble and
securely fasten the one with the tabs to the
outside wall making sure that the labs are on
top and bottom. Fasten the other thimble half
to the inside wall. The thimble halves slip inside
each other and can be &gusted for 2 x 4 or 2
x 6 walls.
5) Slip the assembled liner and termination
assembly through the thimble making sure the
termination cap faces up (there are markings
on the cap indicating which way is up). This
will position the termination cap with proper
down slope for draining water. Fasten the cap
to the outer wall with the 4 supplied screws.
6) Pull the centre inner and outer Ilex liner out
enough to slip over the flue collars of the
fireplace. (You may wish tocutthe liner shorter
to make it more workable.) Do not bend liner
more than 90'. The liners must slip over the
collars a minimum of 14/8".
7) Apply Mill Pac over the fireplace inner flue
collar and slip the inner flex liner down over it
and attach with 3 supplied screws.
8) Do the same with the outer flue collar and outer
flex liner.
9) Apply a bead of silicone between the thimble
and termination and around the outer edge of
the terminal al the wall in order to keep the
water out.
IMPORTANT: Do not locate termination hood
where excessive snow or ice buildup may
occur. Be sure to check vent termination
area after snow falls. and cleat to prevent
accidental blockage of venting system. When
using snow blowers, make sure snow is not
directed towards vent termination area.
ASTROCAP
DIMENSIONS (91W5231P)
Screws
4" (102mm) dia. flue pipe
(3 per
ly
with spring spacer
connection) N 4.
r
1 II
6-7/8" (173mm)
dia. air intake
Wall Thimble 2 pieces
(10" (254mm
Outer Diameter)
Termination
Cap
Screws
(4 per
connection)
Regency Horizon"' HZ40E Gas Fireplace
EFTA00301453
INSTALLATION
UNIT INSTALLATION
WITH VERTICAL
TERMINATION
4" X 6-518" VENTING
(Rigid Vent Systems)
1) Maintain the 1.172" clearances (air spaces) to
combustibles when passing through ceilings,
walls, roofs, enclosures, attic rafter, or other
nearby combustible surfaces. Do not pack
air spaces with insulation.
4IFF
Check 'Venting' Sections for
the maximum vertical rise of the
venting system and the maximum
horizontal offset limitations.
2) Set the gas appliance in its
desired location. Drop a plumb
bob down from the ceiling to the
position of the appliance flue
exit, and mark the location where
the vent will penetrate the
ceiling. Drill a small hole
at this point. Next, drop a
plumb bob from the roof to
the hole previously drilled
in the ceiling. and mark the
Die giaM 1
spot where the vent will penet ate the roof
TI
3) A Firestop spacer must be installed in the floor
or ceiling of every level. To install the Firestop
spacer in a flat ceiling or wall, cut a 10 inch
square hole. Frame the hole as shown in
Diagram 2 and install the firestop.
Note: All vertical terminations are vented
using 4" x 6-5/8" venting and rigid pipe
adaptor #510-994.
11Y(254nun)
—1\
souare hole
framing
firestop
spacer
Diagram 2
4) Assemble the desired lengths of pipe and
elbows. Ensure that all pipes and elbow con-
nections are in the fully twist-locked position
and sealed.
Female
Locking
Lugs
s
cgke.coll
Male
Locking
Lugs
NOTE: For best results and optimum perform-
ance with each approved venting system, It is
highly recommended to apply"Mill-Pac" sealant
(supplied) toevery Inner pipeconnectlon. Failure
to do so may result In drafting or performance
Issues not covered under warranty.Silicone(red
RTV) is optional.
5) Cut a hole in the roof centered on the small
drilled hole placed in the roof in Step 2. The hole
should be of sufficient size to meet theminimum
requirements for clearance to combustibles
of 1.1/2'. Slip the flashing under the shingles
(shingles should overlap half the flashing) as
per Diagram 3.
Diagram 3: The upper half Mho flashing is installed
under the roofing material and not nailed down
until the chimney is installed. This allows for small
adjustments.
6) Continue to assemble pipe lengths.
Note: II an offset is necessary in the attic to
avoid obstructions, it is important to
support the vent pipe every 3 feet. to
avoid excessive stress on the elbows.
and possible separation. Wall straps
are available for this purpose.
Galvanized pipe is desirable above the moans
due to its higher corrosion resistance. Continue
to add pipe sections through the flashing until the
height of the vent cap meets the minimum height
requirements specified in Dia. 4 or local codes.
Note that for steep roof pitches, the vertical
height must be increased. Apoorctraftordown
drafting can result from high wind conditions
near big trees or adjoining roof lines, in these
cases, increasing the vent height may solve
the problem.
Diagram 4
Roof Pitch
Minimum Vent Height
Feet
Meters
flat to 7/12
2
0.61
over 7/12 to 8/12
2
0.61
over 8/12 to 9/12
2
0.61
over 9/12 to 10112
2.5
0.76
over 10/12 to 11/12
3.25
0.99
over 11/12 to 12/12
4
1.22
over 12/12 to 14/12
5
1.52
over 14/12 to 16/12
6
1.83
over 16/12 to 18/12
7
2.13
over 18/12 to 20/12
7.5
2.29
over 2(1/12 to 21/12
8
2.44
7) Ensure vent is vertical and secure the base of
the flashing to the roof with roofing rails, slide
storm collar over the pipe section and seal with
a mastic.
8) Install the vertical termination cap by twist-
locking it.
Note: Any closets or storage spaces. which the
vent passes through must be enclosed.
Regency Horizonm 14240E Gas Fireplace
EFTA00301454
INSTALLATION
HZ40E-NG1 SYSTEM DATA
Min. Supply
Pressure
5" WC (1.25 kpa)
Manifold Pressure
3.5" WC (0.87 kpa)
Orifice Size
440 DMS
Maximum Input
26,000 Btu'h
(7.61 kW)
Minimum Input
18,000 Btu/h
(5.28 KW)
HZ40E-LP1 SYSTEM DATA
Min. Supply Pressure
11" WC (2.73 kpa)
Manifold Pressure
10" WC (2.49 kpa)
Orifice Size
453 DMS
Maximum Input
25.500 Btuth
(7.47 kW)
Minimum Input
21.000 Btuth
(6.15 KW)
HIGH ELEVATION
This unit is approved for altitude 01o4500 ft. (CAN.'
2.17-M91).
GAS LINE
INSTALLATION
Since some municipalities have additional local
codes it is always best to consult with your local
authorities and the CAN/CGA 8149 installation
code.
For USA installations follow local codes and/or the
current National Fuel Gas Code. ANSI Z223.1.
When using copper or flex connectors use only
approved fittings. Always provide a union so that
gas lines can be easily disconnected for servicing.
Flare nuts for copper lines and flex connectors are
usually considered to meet this requirement.
NOTE: A shutoff / dante valve should be sup-
plied in or near the unit (or as per local codes)
for ease of servicing this appliance.
IMPORTANT: Always cheek for gas leaks with
a soap and water solution or gas leak detector.
Do not use open flame for leak testing.
Pilot
Ignitor
PILOT ADJUSTMENT
Periodically cheek the pilot flames. Correct flame
pattern has two strong blue flames: 1 flowing
around the flame sensor and 1 flowing across
the burner (it does not have to be touching the
burner).
Burner o o
000
00 00
000oo001t000oo00
Flame Sensor
Note: If you have an Incorrect flame pattern,
contact your Regency' dealerfor further
Instructions.
Incorrect flame pattern will have small, probably
yellow flames, not coming into proper contact
with the rear burner or flame sensor.
GAS PIPE PRESSURE
TESTING
The appliance must be isolated from the gas sup.
ply piping system by closing its individual manual
shutoff valve during any pressure testing of the
gas supply piping system at test pressures equal
to or less than 1/2 psig. (3.45 kPa). Disconnect
piping from valve at pressures over 112 psig.
The manifold pressure is controlled by a regulator
built into the gas control, and should be checked
at the pressure test point.
Note: To properly check gas pressure, both
inlet and manifold pressures should be
checked using the valve pressure ports
on the valve.
1) Make sure the unit is in the "OFF' position.
2) Loosen the 'IN" and/or "our pressure tap(s).
turning counterclockwise with a
118" wide flat screwdriver.
3) Attach manometerto*IN"androCOUT pressure
tap(s) using a 5116" ID hose.
4) Turn the unit on with the remote or wall switch
5) The pressure check should be carried out with
theunit burning and 'besetting should be within
the limits specified on the safety label.
6) When finished reading manometer. turn off
the unit. disconnect the hose and tighten the
screw (clockwise) with a 118' flat screwdriver.
Note:Screw should be snug. but do not over
tighten.
880 S.I.T. VALVE
DESCRIPTION
1) Pilot adjustment
2) Outlet Pressure Tap
3) Inlet Pressure Tap
4) Pilot Outlet
5) Main Gas Outlet
6) Main Gas Inlet
2
AERATION ADJUSTMENT
The burner aeration is factory set but may need
adjusting due to either the local gas supply or
altitude. Open the air shutter for a blue flame or
close for a more yellow flame.
Minimum Air Shutter Opening:
NG
I/8"
LP
Note: Any damage due to carboning resulting
from improperly setting the aeration
controls is NOTcovered under warranty.
0
Regency Horizon"' HZ40E Gas Fireplace
EFTA00301455
INSTALLATION
AC POWER ADAPTOR INSTALLATION (FOR SUREFIRE SYSTEMS)
An optional AC power adaptor may be Installed as a constant power source for the SureFire system.
IMPORTANT: Recommend removing the 4-AA batteries in the SureFire receiver.
This will avoid battery leakage and power drainage. 4-AA Battery pack may be reinstalled into receiver during power outages.
NOTE: For all Gas Fireplaces 120 volt power must be brought to the receptacle box inside the bottom of the firebox (provided with the unit).
All Freestanding Gas Stoves & Gas Inserts will need a receptacle box located outside near the unit
so that the AC Power Adaptor can be plugged in.
INSTALL AC ADAPTOR WITH SUREFIRE WALL RECEIVER SWITCH ONLY - (WITHOUT REMOTE)
1) Locate-DC Supply" tag on wire harness. For location in unit
2) Connect the male end from AC adaptor to the female end
see remote installation page in owners manual.
tagged -DC Supply" on wiring harness in unit.
3) Plug AC adaptor into 120V wall outlet (or into 120V receptacle if
installed inside the gas fireplace firebox).
4) Neatly tuck any loose AC Power Adaptor wires neatly underneath /
inside the appliance.
Note: Ensure that wires do not touch the underside of the firebox
(keep wires away from the heat as much as possible).
INSTALL AC ADAPTOR WITH SUREFIRE PROFLAME GT / GTM REMOTE
1) Connect the male end of the AC adaptor to the female end of the
wire adaptor (supplied with AC adaptor) together as shown .
Wire adaptor
AC adaptor
2) Locate FCM COM connector on the Remote wire harness -
see manual for location in unit.
FCM -COM
3) Plug in wire adaptor to FCM COM connector - be careful not
to damage ends. This only fits one way.
AC adaptor
wire adaptor
FCM - COM
4) Plug AC adaptor into 120V wall outlet (or into 120V receptacle if
installed inside the gas fireplace firebox).
5) Neatly tuck any loose AC Power Adaptor wires neatly underneath /
inside the appliance.
Note: Ensure that wires do not touch the underside of the firebox
(keep wires away from the heat as much as possible).
Regency Horizon'" HZ40E Gas Fireplace
EFTA00301456
INSTALLATION
WIRING DIAGRAM
This heater does not require a 120V A.C. supply for operation. In case of a power failure. the burner switch and the optional remote control/thermostat will
continue to operate. However. a 120V A.C. power supply is needed for the taniblower operation.
(Do not cut the ground terminal off under any circumstances.)
NOTE: Even if the fan Is not purchased with the unit, it Is still a good Idea to bring power to the receptacle box (provided with the unit) in case the
Ian Is Installed at a later date.
PROFLAME SYSTEM GT
Optional AC Adaptor
0.564.860
High Temperature 1125E )
AMC Power A00004
Optional AC Adaptor
I
0.564.8.50
High Temperature (HST)
AGOG Power Ad40 44
885
POW. Sworn
Coregurabon
886 GMT
%Ste Daarem
Swarms"' Swtth
IMIralnal•
0.564 302
Pradess INC Beard
0.6setitt2
VC Wee Hsenees Ammar
s(das. Piot Gym a CHOI Setts
PROFLAME SYSTEM GTM
Proterne System
Corisstraters
885611AF
wre Dasgrats
MILE-
StreFtre". Switch
CAUTION: Label all wires priori° disconnection
when servicing controls. Wiring errors can cause
improper and dangerous operation.
-E4.1E
,M#
5
ae VIre Harress Cr
0 554 9/ 2
0ncluclors %a CA-4
CRAM Swath)
Wear Clicirtel•
- •
Prcasgrealerd
Caution: Ensure that the wires do not touch any
hot surfaces and are away from sharp edges.
Regency Horizon"' HZ40E Gas Fireplace
EFTA00301457
NSTALLATION
PROFLAME SYSTEM GTMF WITH OPTIONAL FAN
%SASSO Mon
P
L
--Fa4=90:
)
Proflame System
Configuration
885 GTMF
Wye Diagram
SureForems Switch
tr—riti
0 0
O
0.584.523
0.584.905
GTMFS Vilna Meows.
DIO
0
a
0564.1 I
Fan °card Module
Neutral
120V AC Live
60 Hz
0.584.912
DFC Wire HarnessAssembly
(Includes Plot Gin0 8 CPUIPI Switch)
Sera Electrode
Prc8ame DFZD2doere
0584.
Black
White
Ground 'Green
_
Black
Black
Black
®a
Groundis
I
Fan
Fan Thermodisc
(normally open)
Caution: Ensure that the wires do not touch any
hot surfaces and are away from sharp edges.
CAUTION: Label all wires priorto disconnection
when servicing controls. Wiring errors can cause
improper and dangerous operation.
Regency Hodzonm 14241)E Gas Fireplace
EFTA00301458
INSTALLATION
Wire Nuts
14 AWG wire
'Wire Ciampi
*Receptacle Box
inside stove
'Receptacle
(dedicated use
by stove fan only)
Copper Ground)
120 Volts White Deutra11_,
60 Hz
Black jHot)___
14 AWG wire
OPTIONAL FAN WIRING DIAGRAM
WITHOUT PROFLAME GTMF SYSTEM
Lockwasher
Star washer
#8 Ground Lug
(for mobile home)
Fan
ground wire
L
Electrical Connection Alternative Scheme "A",
Power at Stove
Wall Junction Box
`Speed Control
• Switch with
lead wires
(Regency)
Neutral
Black
White
Live
"Green
120VAC
Ground
60 Hz
Black
Ground
Fan
Black
0
Black
Red
Fan Thermodisc
(normally open)
Electrical Connection Alternative Scheme "B",
Power at Switch
Wall Junction Box
----- - - - -
'Speed Control
Switch with lead wires
Black (Hot)
120 Volts WhiteiNesitraiL
60 Hz CCalittGt0urAL__,_
+ __
Wire
• = supplied with fan kit
Other parts are to be supplied
by electrician or installer
Wire Nuts
S
P -14 AWG wire
*Receptacle Box
inside stove
'Receptacle
(dedicated use
by unit Ian only)
Black
•_ S,mpnd ,1
iii till
I ll
'Wire
Clamp111
Caution: Ensure that the wires do not touch any
hot surfaces and are away from sharp edges.
CAUTION: Label all wires prior to disconnection
when servicing controls. Wiring errors can cause
improper and dangerous operation.
40
Regency Horizon"' HZ40E Gas Fireplace
EFTA00301459
INSTALLATION
Optional
REMOTE CONTROL
Use the Regency' Remote Control approved for this unit. Use of other systems
may void your warranty.
The remote control comes with a hand held transmitter.
*Profiame GT remote control 946-700
RF remote. ONIOFF Thermostat. ON/OFF Flame Control
Large blue backlit LCD screen with temperature display receiver.
'Proflame GTM remote control 946-701.
RF remote. ONIOFF Thermostat. ON/OFF Flame Control
Large blue backlit LCD screen with temperature display receiver.
nProflame GTMF remote control 946.702.
RF remote. ONIOFF Thermostat. ON/OFF Flame Control
ON,OFF fan control with 3-stage adjustment. Requires a fan (if not included).
to be installed for fan function to operate.
'Must also chose one of the following which enables the flame to be turned
down using the remote control:
'Modulator Surefire NG 946.693
'Modulator Surefire LP 946-694
Large blue backlit LCD screen with temperature display receiver.
RECEIVER WALL SWITCH
(Included with Unit)
1) Run the supplied 10' of the wire harness through the right or left side gas
inlet opening- connect the ONIOFF wire harness. Be careful not todamage
wire.
2) Choose a convenient location on the wall to install the receiver and the
receptacle box (protection from extreme heat is very important). Run wires
from the fireplace to that location.
3) Connect the wire to the receiver wall switch and install into the low voltage
receptacle box.
Regency Horizon"' HZ40E Gas Fireplace
gal
EFTA00301460
INSTALLATION
WALL MOUNT ON / OFF SWITCH AND BATTERY COMPARTMENT INSTALLATION
AND/OR RECEIVER INSTALLATION
REQUIRED FOR ALL INSTALLATIONS - INCLUDING PROFLAME REMOTE CONTROLS
JMPORTANT INSTAI I ATION NOTE.
The Receiver must be placed inside the supplied (Low Voltage)
junction type wall box and installed into the wall only.
DO NOT INSTALL WITHIN THE CONFINES OF THE FIREPLACE.
Remote Receiver Installation
1. Install the low voltage junction box to the framing, at desired location within 10 ft. from fireplace.
2. Feed the 12 pin connector through the opening at back of junction box.
3. Connect the 12 pin connector to the back of the receiver.
4. Install the Receiver in the Low Voltage Junction box.
5. Insert the 4 AA type batteries in the battery compartment with the correct polarity.
6. Place the slider into the cover plate.
7. Put the Receiver switch in the "OFF position, to allow correct lineup for slider switch.
8. Make sure the Receiver and cover plate words `OW and "Ur are on the same side.
9. Align the slider with the switch on the Receiver and couple the switch into the slider.
10. Align the screw holes.
11. Using the two (2) screws provided secure the cover plate to the Receiver.
Optional Proflame Receiver
Rumples WA Plant
10 ft. wire harness with
12 pin connector
Low Voltage Junction Box
Slider Switch
"1449// Plate
J-Box
Receiver
Diagram 1
Regency Horizon"' HZ40E Gas Fireplace
EFTA00301461
INSTALLATION
GTMF REMOTE INSTALLATION
120 VoltAC power is needed for the fan. The fan can be hard wired if desired.
The receptacle box should be Installed on the right hand side of the unit
by a qualified electrician. The neutral (wider) slot of the polarized receptacle
should be at the top.
Unit must be grounded at all times. Do not cut the ground terminal off
under any circumstances.
Note: Follow instructions below -if unit has not yet been installed -otherwise
skip to existing installtions section.
1) Remove 8 screws to remove front access panel.
2) Remove 2 top screws and loosen 2 bottom screwsto remove side access
panel.
3) Install fan control module (FCM) into bracket on the Inside of the panel.
plug the (FCM) into the outlet in the unit - reinstall the panel with 4 screws
from step 2.
4) Proceed to Step 11.
INTO EXISTING INSTALLATIONS
1) Shut off the gas and power supply to the unit.
2) Remove the faceplate or door frame - see instruction in manual.
3) Remove the glass door.
a) Remove the 3 screws shown below at the bottom of the glass
door.
b) Swing the door out 45° from the bottom and lift up and out.
4) Remove the inner panels - reverse of 'Inner panel installation' in the
installation manual.
5) Remove the burner tray cover by lifting up and out as shown below.
T
• Prior to removing burner - remove crystals, pebbles, spa stones and inner
panels - if installed.
Regency Horizon"' HZ4OE Gas Fireplace
a
EFTA00301462
INSTALLATION
5) Loosen 2 screws at the back of the burner to release it.
6) Remove the burner by sliding it to the right - then lift out.
7) Remove the left access plate by removing 8 screws - see locations below.
8) Once the top panel is removed - the left side panel will be accessible.
Remove 3 screws from the left side access panel In locations shown
below.
Note: Some components have been removed for illustration purposes.
9) Install the fan control module (FCM) through the opening created by the
removed loft side access panel.
Left side access
10) Install the fan control module (FCM) into the bracket as shown below.
0
Regency Horizon"' HZ40E Gas Fireplace
EFTA00301463
INSTALLATION
11) Locate the digital firebox control box.
12) Plug the fan power cord Into the fan control module in the outlet marked
fan. Plug in the FCM wire (from the digital firebox control box wire har-
ness) into the location on the fan control module marked com
13) See Proflame remote instructions for coding remote to receiver as well
as operating instructions.
14) Reverse steps 2-1 for new installations.
Reverse steps 8 - 1 for existing installations.
Regency Horizon"' HZ40E Gas Fireplace
EFTA00301464
INSTALLATION
OPTIONAL FAN INSTALLATION
120 Volt AC power is needed for the fan switch and blower. The fan can be
hard wired if desired. The receptacle box should be installed on the left
hand side of the unit by a qualified electrician. The neutral (wider) slot of the
polarized receptacle should be at the top.
Unit must be grounded at all times. Do not cut the ground terminal off
under any circumstances.
Follow these instructions before the initial installation into the framing. If
installing the optional fan into an exiting installation • follow instructions on
the next two pages.
1) Remove lower front face nailing strips (2 screws per nailing strip).
2) Remove 8 screws to remove front access panel.
3) Slide the fan assembly through the front access panel • slide all the way
back to the back of the two tabs.
Tabs
4) Secure the fan to the floor of the unit with 2 screws. in locations show
below.
5) Connect one of the black wire to the Black wires from the power cord.
(light blue connector). Connect the other end to one spade on the ther-
modisc.
6) Connect the red wire end to the other open spade one the thermodisc.
Connect the other end of the red wire to the black wire from the fan motor.
7) Connect the white wire from the fan motor to the black wire on the power
cord.(dark blue connector).
8) Slide in the thermodisc to the clip in the location shown below.
Thermodisc dip
9) Secure the ground wire from the fan assembly, also secure the ground
wire from the power cord to the stud on the back left near the fan.
10) Plug the fan into the receptacle located in the lower left front corner at
the base of the unit.
NOTE: If installing the fan with a GTMF remote • please see GTMF remote
instructions in the manual.
TO REMOVE THE FAN
1) Turn the power off.
2) Reverse the above instructions.
Maintenance: The sealed bearings are lubricated, there is no need to lu-
bricate them further. (Extra lubricant will cause more lint and dust buildup
- causing the bearings to prematurely fail).
Regular cleaning and vacuuming of the fan area will add to the life of the
motor.
IMPORTANT:
ese fans collect a lot of dust from within your home. Ensure you
maintain these fan motors on a regular basis by vacuuming
he fan blades and housing using a soft brush nozzle.
a
Regency HorlzonTM HZ40E Gas Fireplace
EFTA00301465
INSTALLATION
OPTIONAL FAN INSTALLATION - INTO EXISTING INSTALLATIONS
120 Volt AC power is needed for the fan switch and blower. The fan can be
hard wired if desired. The receptacle box should be installed on the left
hand side of the unit by a qualified electrician. The neutral (wider) slot of the
polarized receptacle should be at the top (see page 41 for wiring diagram).
Unit must be grounded at all times. Do not cut the ground terminal off
under any circumstances.
1) Shut off the gas and power supply to the unit.
3) Remove the faceplate or door frame by lifting it up oft the glass door.
Faceplate
(4pc style
shown)
4) Remove the glass door.
Glass Door
a) Remove the 3 screws shown below at the bottom of the glass
door.
b) Swing the door out 45° from the bottom and lift up and out.
5) Remove the inner panels - reverse of inner panel Installation' in the
installation manual.
6) Remove the burner tray cover by lifting up and out as shown below.
• Prior to removing bumer - remove crystals, pebbles, spa stones and Inner
panels - if installed.
7) Loosen 3 screws at the back of the bumer to release it.
—
1 _ I
'Cl
8) Remove the bumer by sliding it to the right - then lift out.
9) Remove the left access plate by undoing the 8 screws - see locations
below.
Location of screws on access plate
10) Remove the left access plate by undoing the 8 screws - see locations
below.
Regency Horizon*" HZ40E Gas Fireplace
EFTA00301466
INSTALLATION
10) Maneouver fan through left access panel opening.
11) To complete fan Installation - follow steps 2- 7 on previous page.
NOTE: The right access panel wasremoved to allow easier access to secure
the right screw on the fan base.
12) Reverse steps 9-1 to complete install.
C
Regency Horizon"' HZ40E Gas Fireplace
EFTA00301467
INSTALLATION
INNER PANEL INSTALLATION
Handling Instructions
Black Enamel Panels
• Black Enamel panels must be inspected for watches and
dimples prior to installation. All claims to be recorded at this time.
Claims for damage after installation will not receive consideration.
• Black Enamel panels will discolor a little during normal operation.
This
is normal and should not be considered a defect.
* Al hand and finger marks MUST be cleaned off with a soft cloth.
Use an ammonia based cleaner (ie. glass cleaner) to remove any
fingerprints before applying heat to the unit.
Failure to do this will result in bum stain on panels which you
will be unable to remove. Not protected by product warranty.
1) Remove the faceplate and glass door it already installed • see
manual for instructions.
2) Remove 4 screws to remove top heat deflector.
3) Remove installed factory panels.
Loosen 2 screws (do not remove) on panel clip securing side panel.
Slide panel dip down away from screws.
Remove side panel.
panel clap
4) Repeat on opposite side.
5) Remove back panel.
6) Install the back enamel panel first. Tilt the panel lanyard • position
the bottom of the panel first. Use care not to scratch or mar the panel
on the pilot shield.
7) Install the loll side enamel panel • secure in position with the panel
clip and two tighten two screws loosened in step 2, as shown in the
diagram below.
8) Install the right side enamel panel - secure in position with the panel
dip and two screws loosened in step 4.
9) Reinstall heat deflector.
10) Reinstall glass door • reinstall faceplate.
I —
MI
Final /naafi
Regency HorizonTM HZ40E Gas Fireplace
LI
EFTA00301468
INSTALLATION
GLASS CRYSTALS OR OPTIONAL CERAMIC STONES
INSTALLATION ON BURNER
Evenly spread the Glass Crystals or optional Ceramic Spa Stones or Volcanic Stones over the burner. Ensure the crystals (or stones) do not
ovedap too much as this wi effect the flame pattern.
IMPORTANT NOTE:
Onlythe supplied approved Glass Crystals and Ceramic Spa/lava Stones are to be used with these fireplaces. Use of any other type of glass crystals
or stones can alter the tilts performance. any damage caused by the use of any unapproved glass or stones will not be covered under warranty.
When using Ceramic Spa/ Lava Stones DO NOT cover burner ports or riot light that lead to pilot flame. Ensure the crystals or stones do not overlap
excessively as this will effect the flame pattern.
BURNER PACKAGES
Unit
•Glass Crystals
Ceramic Spa / Volcanic Stones
HZ54E 1 HZ54EPV
3 lbs
1 lb Glass + 2 packages (140 spa stones)
HZ42 / I4Z42E I HZ40E 2 lbs
I lb Gass • 1 package (70 spa stones)
HZ42ST / HZ42STE
HZ42STEPV
2 lbs
1 lb Glass + 1 package (70 spa stones)
HZ30E ••
1 lb
I lb Glass + 1 package (70 spa stones)••
HZI234E •••
3141b
3/4 ti Glass + 1 package 70 spa stones)•••
HZI390E/ HZ1390EB •
7 lbs (4 lbs burner + 3 lbs firebox)
2 lb Glass + 1 package (70 spa stones) / 2 lb Glass + 1 package (volcanic stones)
HZI540EB •
8 Ds [4 lbs burner + 4 lbs firebox]
21b Glass +1 package (70 spa stones)/ 2lb Glass + 1 package (volcanic stones)
HZO424-1ZO42 (AUS)
3 lbs
Not Approved
L6765
1 lb
1 package = (70 spa stones)
P33S1233SE •—
1 lbs
I package = (70 spa stones)—
PTO3r/ Plateau Series 10 Ds
Not Approved
PTO60-
20 lbs
Not Approved
U32S / U32SE
1 lb
1 package = (70 spa stones)
E335
1 lb
I package = (70 spa stones)
NOTE: • Glass Crystals are available in llb and 5Ib bags. All units come standard with Cobalt Blue glass crystals except:
• HZO42 comes with Copper glass crystals.
• HZI390E. HZI390EB. HZ1540EB. PTO30. PTO60 8 Plateau Series do NOT include glass crystals with units. Must purchase separately.
• 1 Ceramic Spa stone package contains 70 stones.
Recommended - use only 40 of the 70 ceramic stones on the HZ30E burner.
Recommended - use only 24 of the 70 ceramic stones on the HZ1234E burner.
•••• Recommended - use orgy 50 of the 70 ceramic stones on the P33S/P33SE burner.
Glass Crystals shown on Burner
For Units HZ54E. HZ54EPV. HZ42ST. HZ42STE. HZ42STEPV.
HZ1234E. HZ42E. HZ42. HZ40E. HZ30E.
HZO42. HZO42 (AUS) P7O30. PT060 Plateau Series only
Glass Crystals shown on Burner
For units P33.S. P33SE. L676S. U328. U32SE. E33S only
111
Glass Crystals shown on Burner and Firebox Floor
For Units HZ1.390E. HZI390EB. HZI540EB only
-1Zelitgra'terillififtralltallisam•
Optional Ceramic Spa Stones + Glass Crystals shown on burner.
For Units HZ54E. HZ54EPV. HZ42ST. HZ42STE. HZ42STEPV.
HZ1234E. HZ42. HZ42E. HZ40E. HZ30E only
Optional Ceramic Spa Stones shown on burner.
For units P33aP33SE L676S. U325. U32SE. E33S only
Regency HorlzonTM HZ40E Gas Fireplace
EFTA00301469
INSTALLATION
OPTIONAL PEBBLE / CRYSTAL INSTALLATION
FOR FIREBOX BASE
Firebox (Around Burner) Packages
Unit
Glass Crystals
Pebbles
HZ54E / HZS4EPV
6 lbs
2 packages (6 x bags pebbles)
H242/ HZ42E / H240E
5 les
2 packages (6 x bags pebbles)
HZ42817H242STEMZ42STEPV 5 lbs
2 package (6 x bags pebbles)
HZ30E
2 les
I package (3 x bags pebbtes)
HZI540EB
4 lbs
1.5 packages (4 x bags pebbles)
HZI390e HZI300ES
3 les
I package (3 x bags pebbtes)
HZI234E
2 lbs
1 package (3 x bags pebbles)
82042 / HZ042 (AUS)
3 les
I package (3 x bags pebtores)
P335 / P33SE
3 lbs
I package (3 x bags pebbles)
U32S I U32SE
3 les
1 package (3 x bags pebbles)
E338
3 lbs
I package (3 x bags pebbles)
There are 2 optional packages to choose from to cover the firebox base:
1) Natural River Pebbles
2) Glass Crystals (4 colors available)
Spread the pebbles ? crystals evenly on the exposed base of the firebox. Pebbles are Hat to be placed anywhere on the burner or over top of the
Glass Crystals or optional Ceramic Spa Stones.
IMPORTANT NOTE: Cray the supplied and approved pebbles/glass crystals are to be used with these fireplaces. Use of any other type of pebbles.
glass crystals or other material can create a danger and will void the warranty.
River Pebbles shown surrounding a Sunrise Burner
Natural River Pebbles shown surrounding the a Horizon Burner
Glass Crystals shown surrounding the Burner
Regency Horizonm 14240E Gas Fireplace
EFTA00301470
INSTALLATION
GLASS DOOR INSTALLATION
The glass door comes with a black frame.
1) To install the frame and glass door, simply hook the top door flange onto
the top of the unit and swing the door towards the unit, Diagram 1.
Note: Be careful that the glass gasket does not roll up: there must be a gap
between the gasket and the door lip to ensure that the door sits
securely on the unit. See Diagram 2.
Hook top of
door onto
top flange
Flush
Door
Flush
Door
Gasket
Glass
Correct
Door/Glass/Gasket
Installation.
Incorrect
Gasket:
doubled
up, filling
gap.
Diagram 2
2) With the door in proper position • secure with 2 screws in locations shown
in Diagram 3.
Diagram 3
3) Install cover plates over each screw with 2 magnets each as shown below.
Magnet
Cover Plate
Diagram 4
Cover Plates Installed
Diagram 5
Regency Horizon"' HZ40E Gas Fireplace
EFTA00301471
INSTALLATION
OPTIONAL MESH GLASS GUARD
1) Remove left side and right side door frame screws.
2) Using existing door frame screw, install latrer mesh mounting brackets
on left side and right side. as shown.
Lower mesh mown ing brackets
3) Install mesh screen. flush side facing out.
4) Install left side and right side top mountng dips approximately 3' from
each side.
NOTE: Clips should line up with the edge of the outer edge of the glass
door flange - see glass door nstall for illustration.
Mesh mounting clips
5) Install faceplate - refer to faceplate installation instructions in manual.
Regency Horizon"' HZ40E Gas Fireplace
EFTA00301472
INSTALLATION
4 PIECE FACEPLATE INSTALLATION
1) If installing optional mesh glass guard - See °Monet 'Mesh Glass
Guard' installation instructions.
2) Instal brackets onto me back of me faceplate - 3 screws for each
bracket in locations shown below.
3) To instal me 4 pc. faceplate - hook brackets (located on back of
faceplate) over the two middle tabs on the glass door frame.
If thicker finishing materials are used - the faceplate may be
adjusted out - up to lir
1 NV?
.1H'
Use era notch al bracket
for standard instagetton
Edge of
Hangs on
fireplace
1 44 (38mm)
Hook bracket over
these tabs
Important: L2' gap required between faceplate and
Wished mai when using part 0256-924. 256-926.256-
927 (4 pc. faceplate).
Final Instal
Regency HorizonTM HZ40E Gas Fireplace
EFTA00301473
INSTALLATION
INNER AND OUTER DOOR FRAME INSTALLATION
Note: HZ40E only - if instilling optional mesh glass guard -
See optional mesh glass guard instruction in the manual.
1) Install 4 magnets onto 4 comers of glass frame prior to installing
the inner door frame.
2) Install the inner door frame - lit it over the glass door frame.
3) Instal theouterdoorframeto the uni1by hooking the left and right sxle
mounting brackets into the mounting slots at the sale of the firebox
as shown below. It is recommended that you use the first mounting
slot (the one closest to the door frame overlay) out of the 3 so that
the faceplate and door frame overlay are flush with one another.
NOTE: There are 3 mounting slots available. this is toaccommodate
any finishing that protrudes sightly beyond the faceplate.
Pin
Fl
Tab on Faceplate
Bracket in Una
CompletoO .nner occr
frame and faceplate
instatfabon
Note:
Inner door frame may be installed by itself, or with the outer
door frame.
The outer door frame cannot be installed by itself - if install-
ing the outer door frame - the inner door frame must also be
installed.
918-905a
1
08124111
Regency Horizon*" HZ40E Gas Fireplace
EFTA00301474
OPERATING INSTRUCTIONS
OPERATING
INSTRUCTIONS
1) Read and understand these instructionsbefore
operating this appliance.
2) Check to see that all wiring is correct and
enclosed to prevent possible shock.
3) Check to ensure there are no gas leaks.
4) Make sure the glass in the glass door frame
is properly positioned. Never operate the
appliance with the glass removed.
5) Verify that the venting and cap are unobstructed.
6) The unit should never be turned off, and on
again without a minimum of a 60 second wait.
FIRST FIRE
The FIRST FIRE in your heater is part of the paint
curing process. To ensure the paint is properly
cured, it is recommended you burn your fireplace
for at least four (4) hours the first time.
When first operated. the unit will release an odour
caused by the curing of the paint and the burning
off of anyoilsremaining from manufacturing. Smoke
detectors in the house may go off at this time. Open
a few windows to ventilate the room for a couple of
hours. The glass may require cleaning.
NOTE: When the glass is cold and the appliance
is lit, it may cause condensation and fog
the glass. This condensation is normal and
will disappear in a few minutes as the glass
heats up.
DO NOTATTEMPTTO CLEAN THE GLASS
WHILE IT IS STILL HOT!
DO NOT BURN THE UNIT WITHOUT THE
GLASS DOOR IN PLACE.
During the first few fires, a white film
maydevelop on the glass front as part of
the curing process. The glass should be
cleaned after the unit has cooled down
or the film will bake on and become very
difficult to remove. Use a non-abrasive
cleaner and DO NOT ATTEMPT TO
CLEAN THE GLASS WHILE IT IS HOT.
LIGHTING
PROCEDURE
IMPORTANT
To ignite or reignite the pilot, you
must first remove the glass door.
1) Press and release on ON:OFF button once
on the remote control or ON/OFF switch.
2) After approximately 4 seconds the spark
ignition system will spark for 60 seconds to
light the main burner.
3) The unit will turn on.
Note: The first try for Ignition will last approxi-
mately60seoonds. If thereisnoflame ignition
(rectification) the board will stop sparking for
approximately 35 seconds. After wait time
the board will start second try for ignition
by sparking for approximately 60 seconds .
If there is still no positive ignition the board
will go into lock out.
The system will need to be reset as follows:
a) Turn the system off using ON/OFF switch
or press ON/OFF button • if using optional
remote.
b) After approximately 2 seconds turn on ON/
OFF switch or press ON/OFF button if using
optional remote.
c) Repeat step 2.
If the appliance will not operate, follow the
instructions "To Turn Off Gas to Appliance"
and call your service technician or gas
supplier.
SHUTDOWN
PROCEDURE
1) Turn the wall mounted switch or remote to
the "OFF" position.
2) Press 'OFF' on the remote control.
NORMAL OPERATING
SOUNDS OF
GAS APPLIANCES
It is possible that you will hear some sounds from
your gas appliance. This is perfectly normal due to
the fact that there are various gauges and types
of steel used within your appliance. Listed below
are some examples. All are normal operating
sounds and should not be considered as defects
in your appliance.
Burner Tray:
The burner tray is positioned directly under the
burner and is made of a different gauge material
from the rest of the firebox and body. Therefore, the
varying thicknessesof steelwillexpandancicontract
at slightly different rates which can cause 'licking'
and "cracking' sounds. You should also be aware
that as there are temperature changes within the
unit these sounds will likely re-occur. Again, this is
normal for steel fireboxes.
Pilot Flame:
While the pilot flame is on it can make a very slight
"whisper" sound.
Gas Control Valve:
As the gas control valve turns ON and OFF, a
dull clicking sound may be audible, this is normal
operation of a gas regulator or valve.
Unit Body/Firebox:
Different types and thicknesses of steel will expand
and contract at different rates resulting in some
"cracking" and "ticking' sounds will be heard
throughout the cycling process.
Blower Thermodlsc:
When this thermally activatedswitch turns ON it will
create a small "clicking" sound. This is the switch
contacts closing and is normal.
Regency Horizon"' HZ40E Gas Fireplace
EFTA00301475
OPERATING INSTRUCTIONS
COPY OF LIGHTING PLATE INSTRUCTIONS
FOR YOUR SAFETY READ BEFORE LIGHTING
-
TIM appllance must be installod In accoedanco MUI bral codes. II any:
Il none. loges th* National Font Cas Code. »al 2223.UNFPA 54. or
Nattmal Cas and Program In/ aandien Codes, CSA B141.1
WARNING: II you do not fellow these instructions exactly. a lire er explosion may fezelt
tauzing preparty damage. personal Injury or loss of file. Improper instal lallen. adjustment.
alterahon. service or maintenance ten cause injury or property dametje. Refer to the ownees
information menuet provided with this appliance. For assistente or additional information
consult a qualilied insteller. service agency or gas supplier.
AVERTISSEMENT. Ouiconque ne respecte pas á la lettre les instructions dans la presente notiee
risquede déclencher u '
'
uneexplosion entrainant des
des blessures ega
mort. Une installation.
de medification.deserviceou
peut provoquer des
blessures ou des dommages ma erwt,. Reportez•vous au menuet u propt
ire de rinformation
fournie avec cel :Beparelt. Peur obtenir de raide ou des inlormations supplémentaires tonuller
un installateur geologe. une agente de service ou fournisseur de gaz.
A) ibis ~hamen cpapped vees art IgnOon amme ehichaldenalealy sghis iho o/ol.
Dona sy b fghl dm pk) by eend.
B) BEFORE OPERATING snee MI Rand !he ~erna OM fer EM. Be etre le enne oen s, ge hm,
botaus* tann gis m barut [han alt end Mi soli» on eti box
VMATTOOOIFVOU SNEU. CAS
- Don« bylolittenyezerinee.
• Do not touch Day stetest Mick da nol uso arry phono in das bulding.
• Immedlay ron yo.rgassuppler kon a neighbous necne. Forma dm gas suppedys calruCba,
• II ytYJ om« Mede treur gal Papptet. cal dm fee depeilmeni.
C) De nol zee The apeliVraellanyMel hes been Omkenter Immedady alla ~Wel service
tocImMan to Impact lep opplenen and roplaco arry pan WIM control sysum and any
pas oanird %%Neb bas been underwalor.
G) Cel apentelg aar
diaah)
bui /gumt eutematiquement le miteuee
No lento pas
a voticsno memo
B)AVANT DE FAIRE FONCT1ONNER. renner DR aitar de lapparel pour ~dor am <cc-,
dego. Rasnet erts du ortinchm. cv totoks g« Smit Diorti4dir Ra Oor el peuven:
8.erraiMuler ee niveau du sol.
OUE FARE Si VOUS WOU UNE COEUR DE 43AZ:
• Ne Oe lente( WE
• Ile Molmt i alt m «Item/plm. ne pee MMInsi des Matptmee se Ircvmanl dans le
baansent.
-Appelez nwedialemeni enho toonamm do gat doom un vaan Sumaz les
metageis du reuma em
• S: voos ne panset mitste le legml meur. acetat le ~b°, ene anneks
Cl OM
pas col enorm se aØ Ocege aanstorm. MMO parhollomont, Fades irrigator I appatol par un toch.
noen godtfil el real layez Mulo ~Ie di systime de conhOW el lokte commtsle eo. ent 410 plenaire &n I eau
CAUTION: Hot whie in *penden. Do not touch. Severe Burns may result. Due to high surface
ternperatures keep chRdren. clothing and furngure.gasoline and ether liquide hoving flammable
vapors away. Keep burner and control compartment clean. See installation and operating
instructions accompanying appliance.
OPERATING INSTRUCTIONS
STOP! Read the safety information above on Ns label.
ll nam on ØF
switch
2) ARM ePflrosirnatelY I timend* Uw spark ignalnal syarm vin *park fa 40 iemands le light Re main
Immer,
3) Re eelt vnll turn on.
Nota: The Rat anemie' Iro Ignition wel last approximatoly 60 seconde.. II teem Is no name [gallon troctillca•
timp th* boardME stop onreine let approMmilety 15 maand,. After INti weitime. Ms board wIll start a
ristend to lor ignition by eparkIng tor appmaimately 60 monde. IV Thee, in elIll no posidve Ignhion ener tnt
second anemel th* board MUI go INC lock out.
Tin system wal nood to be fesol as folkwes (alter goIng Ina lotto.« mode):
a) Tom Cie spleen ofl esing ROOF, crash
Vlag 5 Mnute' to daar out any gas. Tinto smelt lor ges. blote:eng nou Te nov.
Il you smell gas STOMERIJ/ra stop '
In the Satety information above on this label. It you dool smolt gas.
go to the nest slep.
bi Turn on °ROEF match er press ØF
button II sang optional ~Me,
c) Unit mil repeat step 2.
It lbo epigram* Mg not opmat*. kaow the instructIons me Tum On Gas to Appllance" and earl your
service technician or ges supPliw
STOP! Lire les consignes de sécurité cidessus sur tette Etiquette
1) Aanwet le bouten OIO OFF
2) Allerdre a seconden. te eysléme
produira des 'Onmens pendant 10 secondes abn-
lo Orateur penlaat.
9) les Rammen n'allumeront.
ftsmarque ' Au
le
flanwies
60
Si Fesal
premier allurnage.
systeme lente
jles
pendant
secondes
est moutoryx. le system lalt un pause <l
e... 'old co pion appeae telededo
rectlfkathan.
atal
Co
al OcoM.
systems lento d nouveau
les dommes en produlsaM des seincodes pendant%
seconden. Si les Rammes ne trallunent Muleta* pan. Ie eyeAéme se mel en mede venomalege.
H fer /dom le réinklelieer en suivant lee *Mee sidesaus Ipour Ie ~mondt«) :
a) beIgnia le systemo en utaisant nntenupteur ON t OFF.
Mende* 5 minute* peur bisser *Rapper toet le gab Puls somt« pons uno *dat do pm. y tempels pees du
plancherli mus ambo une odeur de gat ARReitz, Stayer Mime lam des consigne, de sluret cldeseue
em tall. étiquelle. SI MIS na tantes pas de gas. passes i ritme suivante.
b) Et ralla or le sysame a raldo de l'Internapteur ou do la tatecomnando.
c) L'unatá repelera retort 2.
SI rappere« ne toneonna pas. sundt los Instructions "aow cours le gat a rappe/odb et appel« volro lach.
Mcien mi volte knamleseur de ged.
TO TURN OFF GAS APPLIANCE
1)
Turn ott OreOFF svritth
2)
tt service is to be pertomwd • you MUM clisconnect power to tact unit hom tb, baeery pack. retor to
manual.
1)
Ap1/11yOZ slit le bouten ON 1 OFF
2)
SI Ie bonk* est offottuée. voos dam clabrancter rapperell. W Moed:dos. vok lo manual
POLI' plus de Mails.
DO NOT REMOVE THIS INSTRUCTION PLATE
Mt.426.
Regency Horizon"' HZ40E Gas Fireplate
EFTA00301476
MAINTENANCE
MAINTENANCE
INSTRUCTIONS
1) Always turn off the gas and electrical supply
before cleaning. For relighting. refer to lighting
instructions. Keep the burner and control
compartmentcleanbybrushingandvacuuming
at least once a year.
2) Clean appliance and door with a damp cloth
(never when unit is hot). Never use an abrasive
cleaner. The glass shou Id be cleaned with a gas
fireplace glass cleaner. The glass should be
cleaned when it starts looking cloudy.
3) The faceplate is finished in a heat resistant
paint and should only be refinished with heat
resistant paint. Regency' uses StoveBright
Paint Metallic Black #6309.
Note: Faceplates and Inner panels made from
stalnlesssteelwillnaturallychangecolor
over time.
4) Make a periodic check of burner for proper
position and condition. Visually check the flame
of theburner periodically. making suretheflames
are steady: not lifting of floating. If there is a
problem. call a qualified service person.
5) The appliance and venting system must be
inspected before use. and at least annually, by
a qualified field service person. to ensure that
the flow of combustion and ventilation air is not
obstructed.
Note: Never operate the appliance without the
glass properly secured in place.
6) Do not use this appliance if any part has been
underwater. Immediately call a qual if ied service
technician to inspect the appliance and to
replace any part of the control system and any
gas control which has been under water.
7) In the event this appliance has been serviced
checkthatthevent-airsystem hasbeen properly
resealed & reinstalled in accordance with the
manufacturers instructions.
8) Verily operation after servicing.
GLASS GASKET
If the glass gasket requires replacement use a
tadpole glass gasket (Part # 936-159).
GLASS DOOR
Your Regency° fireplace is supplied with high
temperature 5mm-Ceramic glass. If your glass
requires cleaning, we recommend using an
approved glass cleaner available at all authorized
dealers. Do not use abrasive materials.
CAUTION & WARNINGS:
' Do not clean when the glass is hot.
' The use of substitute glass will void all product
warranties.
• Care must be taken to avoid breakage of the
glass.
• Do not strike or abuse the glass.
• Do not operate this fireplace without the glass
front or with a cracked or broken glass front.
• Weargloves when removing damaged orbtoken
glass.
• Replacement of the glass panel(s) should be
done by a licensed or qualified service per son.
GLASS REPLACEMENT
In the event that you break your glass by impact.
purchase your replacement from an authorized
Regency' dealer only.
Replacement neocetamic glass
(Part # 9403611P) is shipped with gasket.
CAUTION: Weargloves when removing
damaged or broken glass.
WARNING: Do not operate the
appliance with the glass panels
removed, cracked or broken.
Replacement of the glass panels
should be done by a licensed or
qualified service person.
GENERAL VENT
MAINTENANCE
Conduct an inspection of the venting system semi-
annually. Recommended areasto inspect asfollows:
1) C heck the Venting System for corrosion in areas
that are exposed to the elements. These will
appear as rust spots or streaks. and in extreme
cases. holes. These components should be
replaced immediately.
2) RemovetheCap. and shinea flashlight down the
Vent. Remove any bird nests. or other foreign
material.
3) Cheddorevidencesofexcessivecondensation.
such as water droplets forming in the inner
liner, and subsequently dripping out the joints.
Continuous condensation can cause corrosion
of caps. pipe. and fittings. It may be caused
by having excessive lateral runs. too many
elbows, and exterior portions of the system
being exposed to cold weather.
4) Inspect joints. to verity that no pipe sections or
fittings have been disturbed, and consequently
loosened.Alsocheck mechanical supports such
as Wall Straps. or plumbers' tape for rigidity.
Regency Horizon"' HZ40E Gas Fireplace
EFTA00301477
MAINTENANCE
VALVE ASSEMBLY REPLACEMENT
1) Turn the unit off and allow it to cool down to room temperature.
2) Shut off the gas and power supply to the unit.
3) Remove the faceplate or door frame -see instruction in this manual.
4) Remove the glass door.
a) Remove the 3 screws shown below at the bottom of the glass
door.
b) Swing the door out 45° from the bottom and lift up and out.
5) Remove the inner panels - reverse of 'Inner panel Installation' in this
manual.
6) Remove the burner tray cover by lifting up and out as shown below.
' Prior to removing burner - remove crystals. pebbles, spa stones and inner
panels if installed.
7) Remove 3 screws on the bumer to release it - locations shown below.
8) Remove the burner by sliding it to the right then lift out.
1
9) Remove the valve access plate by undoing the 8 screws - see locations
below.
10) Disconnect the inlet gas line and remove the valve
Illata.;;;;;
NaiL
r
11) Replace valve assembly and reverse steps.
Regency Horizon*" HZ40E Gas Fireplace
EFTA00301478
PARTS LIST
MAIN ASSEMBLY
Part If
Description
Part a
Description
1
256-038
Frame Door HZ40E
6
911-024
Valve NG 880 SIT IPI
2
940-361/P
Glass Neoceram Flush HZ40E
911-025
Valve LP 880 SIT IPI
3
256-039
Bottom Tray HZ40E
7
911-006
Pilot Assembly IPI NG
4
256-525
Burner Assembly NG c/w Cap HZ40E
911-007
Pilot Assembly IPI LP
256-530
Burner Assembly LP c/w Cap HZ40E
8
256-574E/P
Valve Assembly HZ40E NG SIT
5
904-345
Orifice #53 LP
256-576E/P
Valve Assembly HZ40E LP SIT
904-593
Orifice a40 NG
9
910-157/P
Fan Low Speed (Dual Blower)
911-012
Ignition board
911-013
IPI/CPI Switch
Not Shown
60
Regency Horizon TM HZ40E Gas Fireplace
EFTA00301479
PARTS LIST
ACCESSORIES
Pait #
10)
316-907
316-908
11)
256-924
256-926
256-927
256-934
256-936
256-947
256-944
256-946
256-947
946-676
946-672
946-673
946-674
Description
Reflective Stainless Steel Inner Panels
Black Enamel Inner Panels
Faceplate Black
Faceplate Sunset Bronze
Faceplate Brushed Stainless
Outer Door Frame Black
Outer Door Frame Bold
Outer Door Frame Stainless
Inner Door Frame Black
Inner Door Frame Bold
Inner Door Frame Stainless
Copper Glass Crystals
Natural River Pebbles
White River Pebbles
Ceramic Spa Stones
11
Regency Horizon"' HZ40E Gas Fireplace
EFTA00301480
NOTES
Regency Horizon"' HZ40E Gas Fireplace
EFTA00301481
WARRANTY
OR
FIREPLACE PRODUCTS
('
Regency' Fireplace Products are designed with reliability and simplicity In mind. In addition. our Internal Quality Assurance Team carefully inspects each unit thoroughly
before it leaves our facility. Regency* Fireplace Products is pleased to extend this limits lifetime warranty to the ordained purchaser of a Regency' Product. This warranty is
not transferable.
The Warranty: Limited Lifetime
The combustion chanter. heat exchanger. burner tubesiVans. logs. glass crystals. ceramic spa stones, potties. ea* panels and gold pasting (against defective manufacture only) are
covered under the Limed Warne Warranty for five (5) years for parts and subsidized labour' and pads only thereafter.
Glass is covered for lifetime against thermal breakage only. pans and subsidized labour' for live (5) years and pans only thereafter from date 01 purchase.
External casting, surrounds and grills are covered against cracks and warps resultng from manufacturer defects. pans and subsidized labour for three (3) years from the date of purchase
and pads only thereafter.
Special Finishes One year on stainless steel panes. nickel overlays.nickel taceplates. Crushed nickel and antique copper full screens and doors. You can expect some changes ri color
as the product 'ages' with constant heating and cooling. Regency warranties the product for any manufacturing defects on the original product. However. the manufacturers warranty does
not cover changing colors and marks. ie. finger prints. etc applied after the purchase of the product. Damage from the use of abrasive cleaners is not covered by warranty.
Electrical and mechanics components such as blowers. switches. wiring, themiodiscs. Regency° remote controls. spa switches. themvpiles. thermocouples. plot assembly components.
and gas valves are covered for Iwo years pans and one year subsidized labour' from the date of purchase. Blowers and valves replaced under warranty are considered repairs and continue
as if new with appbance. ie. lweNe 112) months from original purchase date ci appliance with a minimum 01 three (3) months coverage from date of replacement.
Regency venting components are covered pans and subsidized labour' for three (3) years from date of purchase.
Simpson Dura-Vent venting conponents (Direct Vent units) are covered by Simpson Dura-Vent Inc. warranty.
Repair/replacement pans purchased by the consumer from Regencye after the original coverage has expired on the unit will carry a 90 day warranty. valid with a receipt only. Any nem
shorn to be defective will be repaired or replaced at our discretion. No labor coverage is included vnth these pans.
Conditions:
Any pan or pads of this unit which in our judgement show evidence of such defects will be repaired or replaced at Regency's option. through an accredited distnbutor or agent provided that
the defective pan be relumed to the distnbutor or agent Transportation Prepaid if requested.
Porcelain£namel - Absolute perfection is either guaranteed nor commercially possible. My chips must be reported and inspected by an authorized dealer within three days of instalation.
Reported damage after this time will be subject to rejection
It is the general practice of Regency. to charge for larger, higher priced replacement pans and issue credit once the replaced component has been returned to Regency and evaluated for
manutaclurer defect.
The authorized selling dealer is responsible for all n -field service work earned out on your Regencr product. Regency will not be liable for results or costs of workmanship from unauthorized
service persons or dealers.
At as times Regency reserves the right to inspect product in the field which is claimed to be defective.
Al claims must be submitted to Regencye by authorized selling dealers. It is essential that as submitted class provide all 01 the necessary information including customer name. purchase
date. serial N. type of unit, problem. and pad or parts requested. without this information the warranty will be invald.
Exclusions:
This limited Lifetime Warranty does not extend to or include paint. door or glass gaskebng or Inn.
At no time via Regency° be liable for any consequential damages which exceed the purchase prize 01 the unit. Regency'shas no orolgation to enhance or modify any unit once manufactured.
ie. as products evolve. field modifications or upgrades will not be performed.
Regency° will not be liable for travel costs for service work.
Installation and environmental problems are not the responsibility of the manufacturer and therefore are not covered under the terms of this warranty policy.
Embers. rockwool. gaskets, door !uncles and pawn are not covered under the terms of this warranty policy.
Any unit which shows signs of neglect or misuse Is not covered under the terms of this warranty policy.
The warranty via not extend to any pad which has been tampered with or altered in any way, or in our judgment has been subject to misuse. improper instalation. negbgence or accdent
spillage or downdrafts caused by enwonnental or geographical conditions. inadequate venblation. excessive onsets. negative art pressure caused by mechanical systems such as lumaces.
fans. clothes dryer. etc.
Freight damage to stoves and replacement pads is not covered by warranty and is subsol to a claim against the freight carrier by the dealer.
Regency will not be liable for acts 01 God, or acts 01 terrorism. which cause mallunclion 01 the appliance.
Performance problems due to operator error will not be covered by this warranty policy.
Products made or provided by other manufacturers and used in conjunction with the operation of this appliance without prior authorization from Regency.. may nobly your warranty on
this product.
My alteration to the lint which causes sooting or carbonng that resins in damage to the interior / exterior facia is not the responsibility of Regency°.
• Subskly according to job scale as predeterrnmed by FPI.
Regency HorizonTM HZ40E Gas Fireplace
EFTA00301482
Register your Regency° warranty online
www.regency-fi
Reasons to register your product online today!
• View and modify a list of all your registered products.
• Request automatic email notification of new product updates.
• Stay informed about the current promotions, events, and special
offers on related products.
Installer: Please complete the following information
Dealer Name & Address:
Installer:
Phone #:
Date Installed:
Serial No.:
Regency Honzon and SureFire are trademarks of FPI Fireplace Products International Ltd.
© Copyright 2012 FPI Fireplace Products International Ltd. All rights resented.
Printed in Canada
EFTA00301483
Document Preview
PDF source document
This document was extracted from a PDF. No image preview is available. The OCR text is shown on the left.
This document was extracted from a PDF. No image preview is available. The OCR text is shown on the left.
Extracted Information
Dates
Document Details
| Filename | EFTA00301420.pdf |
| File Size | 5379.2 KB |
| OCR Confidence | 85.0% |
| Has Readable Text | Yes |
| Text Length | 128,614 characters |
| Indexed | 2026-02-11T13:24:45.028868 |